Compact LaBr3: Ce Gamma Ray Detector with Si-APD Readout

被引:0
作者
Flamanc, Jeremy [1 ]
Rozsa, Csaba [1 ]
机构
[1] St Gobain Crystals, F-77140 St Pierre Les Nemours, France
来源
APPLICATION OF ACCELERATORS IN RESEARCH AND INDUSTRY | 2009年 / 1099卷
关键词
avalanche photodiode; energy resolution; scintillator; LaBr(3): Ce; gamma detection; AVALANCHE PHOTODIODES; SCINTILLATOR;
D O I
暂无
中图分类号
O59 [应用物理学];
学科分类号
摘要
BrilLanCe 380 (TM) (LaBr(3):Ce) crystal scintillators available from Saint-Gobain Crystals have achieved 2.6% FWHM for 662keV photons (1). This is accomplished with PMT light sensors. Attempts to have similarly good results with PIN photo-diodes and APDs have not been successful. PIN photodiodes do not have any gain and the signal to noise ratio is poor at room temperature. Similarly, even though APDs have sufficient gain, they have poor signal to noise at room temperature. Recently there have been improvements in APDs decreasing the internal noise and increasing their sensitivity, making them an excellent light sensor. With the improved APD, it is now possible to achieve performance with a solid state light sensor comparable to that of PMTs. We have measured 2.8% for 662keV gamma rays at room temperature using an APD for a light sensor on a 20mm long crystal of 1.6cc volume. APDs have advantages of compactness, inherent ruggedness and minimal sensitivity to magnetic fields. Such a device is very practical for hand held and portable field measurement applications(1). ((1)Performance reported in SGC literature.)
引用
收藏
页码:79 / 83
页数:5
相关论文
共 11 条
[1]   Readout of a LaCl3(Ce3+) scintillation crystal with a large area avalanche photodiode [J].
Allier, CP ;
van Loef, EVD ;
Dorenbos, P ;
Hollander, RW ;
van Eijk, CWE ;
Krämer, KW ;
Güdel, HU .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 485 (03) :547-550
[2]  
BLANCO BF, NDIP 08 C
[3]   Study of LaCl3:Ce light yield proportionality with a hybrid photomultiplier tube [J].
D'Ambrosio, C ;
de Notaristefani, F ;
Hull, G ;
Cenceill, VO ;
Pani, R .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 556 (01) :187-191
[4]   Gamma-ray spectroscopy with LaBr3:Ce scintillator readout by a silicon drift detector [J].
Fiorini, C. ;
Gola, A. ;
Zanchi, M. ;
Longoni, A. ;
Lechner, P. ;
Soltau, H. ;
Strueder, L. .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (04) :2392-2397
[5]  
HITOMI K, 2007, P SPIE, V6706
[6]   Recent progress of avalanche photodiodes in high-resoution X-rays and γ-rays detection [J].
Kataoka, J ;
Saito, T ;
Kuramoto, Y ;
Ikagawa, T ;
Yatsu, Y ;
Kotoku, J ;
Arimoto, M ;
Kawai, N ;
Ishikawa, Y ;
Kawabata, N .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 541 (1-2) :398-404
[7]   Performance of large lanthanum bromide scintillators [J].
Menge, Peter R. ;
Gautier, G. ;
Iltis, A. ;
Rozsa, C. ;
Solovyev, V. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 579 (01) :6-10
[8]   Avalanche photodiodes in scintillation detection [J].
Moszynski, M ;
Szawlowski, M ;
Kapusta, M ;
Balcerzyk, M .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 497 (01) :226-233
[9]   BGO readout with photodiodes as a soft gamma-ray detector at -30°C [J].
Nakamoto, T ;
Fukazawa, Y ;
Ohsugi, T ;
Kamae, T ;
Kataoka, J .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 536 (1-2) :136-145
[10]   High energy resolution scintillation spectrometers [J].
Shah, KS ;
Glodo, J ;
Klugerman, M ;
Higgins, WM ;
Gupta, T ;
Wong, P .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (05) :2395-2399