A calibration method for phoswich detectors

被引:8
作者
Gawlikowicz, W [1 ]
Toke, J [1 ]
Schröder, WU [1 ]
机构
[1] Univ Rochester, Dept Chem, Rochester, NY 14627 USA
关键词
phoswich detectors; energy calibration; particle identification;
D O I
10.1016/S0168-9002(02)01230-5
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A new method of particle identification and energy calibration is proposed for phoswich detectors consisting of a fast plastic scintillator optically coupled to a CsI(Tl) crystal. In this method, functional relationships between integrated yields of three properly selected portions of the observed composite light output signal are parameterized in terms of three physical components (overlapping in time) of this signal. Then, a complete set of calibration constants is derived, linking these integrated partial yields to particle atomic numbers (Z) and energies (E). The calibration is based on the correlations between partial yields observed in actual data from the physics or "production" runs, and energy deposits calculated for detector elements. The method is found suitable for a wide range of incident particle species and energies, largely eliminating the need for costly and time-consuming conventional calibration experiments with a variety of beams, targets, and bombarding energies. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:181 / 193
页数:13
相关论文
共 10 条
[1]   CHARGED-PARTICLES IDENTIFICATION WITH A CSI(TI) SCINTILLATOR [J].
ALARJA, J ;
DAUCHY, A ;
GIORNI, A ;
MORAND, C ;
POLLACO, E ;
STASSI, P ;
BILLEREY, R ;
CHAMBON, B ;
CHEYNIS, B ;
DRAIN, D ;
PASTOR, C .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 242 (02) :352-354
[2]  
Birks J. B., 1967, THEORY PRACTICE SCIN, DOI [10.1016/C2013-0-01791-4, DOI 10.1016/C2013-0-01791-4]
[3]  
CEBRA DA, 1992, NUCL INSTRUM METH A, V313, P372
[4]   THE PARTICLE DETECTOR ARRAY AMPHORA [J].
DRAIN, D ;
GIORNI, A ;
HILSCHER, D ;
RISTORI, C ;
ALARJA, J ;
BARBIER, G ;
BERTHOLET, R ;
BILLEREY, R ;
CHAMBON, B ;
CHEYNIS, B ;
CRANCON, J ;
DAUCHY, A ;
DESESQUELLES, P ;
FONTENILLE, A ;
GUYON, L ;
HEUER, D ;
LLERES, A ;
MAUREL, M ;
MONNAND, E ;
MORAND, C ;
NIFENECKER, H ;
PASTOR, C ;
POUXE, J ;
ROSSNER, H ;
SAINTMARTIN, J ;
SCHUSSLER, F ;
STASSI, P ;
TOURNIER, M ;
VIANO, JB .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1989, 281 (03) :528-538
[5]   Calibration of plastic phoswich detectors for charged particle detection [J].
Fox, D ;
Bowman, DR ;
Ball, GC ;
GalindoUribarri, A ;
Hagberg, E ;
Horn, D ;
Beaulieu, L ;
Larochelle, Y .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 374 (01) :63-69
[6]  
GAWLIKOWICZ W, 1998, DOEER4041411
[7]   Characterization of reaction mechanisms in the Ca-40+Ca-40 reaction at E-lab=35 MeV/nucleon [J].
Pawlowski, P ;
Benchekrovn, D ;
Bisquer, E ;
Brzychczyk, J ;
Chabane, A ;
Charvet, M ;
Cheynis, B ;
Cole, AJ ;
Demeyer, A ;
Desesquelles, P ;
Gawlikowicz, W ;
Gerlic, E ;
Giorni, A ;
Grotowski, K ;
Guinet, D ;
Hachaj, P ;
Heuer, D ;
Lautesse, P ;
Lebreton, L ;
Lleres, AL ;
Micek, S ;
Planeta, R ;
Sosin, Z ;
Stern, M ;
Vagneron, L ;
Viano, JB ;
Wieloch, A .
ZEITSCHRIFT FUR PHYSIK A-HADRONS AND NUCLEI, 1997, 357 (04) :387-398
[8]   DWARF BALL AND DWARF WALL - DESIGN, INSTRUMENTATION, AND RESPONSE CHARACTERISTICS OF A 4-PI CSI(TL) PLASTIC PHOSWICH MULTIDETECTOR SYSTEM FOR LIGHT CHARGED-PARTICLE AND INTERMEDIATE MASS FRAGMENT SPECTROMETRY [J].
STRACENER, DW ;
SARANTITES, DG ;
SOBOTKA, LG ;
ELSON, J ;
HOOD, JT ;
MAJKA, Z ;
ABENANTE, V ;
CHBIHI, A ;
HENSLEY, DC .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 294 (03) :485-503
[9]  
TOKE J, 1995, NUCL PHYS A, V583, P519
[10]  
WESTFALL GD, 1985, NUCL INSTRUM METH A, V238, P238