On the use of lock-in thermography to monitor delamination growth in composite panels under compression

被引:10
作者
Toscano, Cinzia [2 ]
Riccio, Aniello [1 ]
Camerlingo, FrancescoPaolo [3 ]
Meola, Carosena [4 ]
机构
[1] Univ Naples 2, Dept Ind & Informat Engn, I-81031 Aversa, Italy
[2] Italian Aerosp Res Ctr CIRA, I-81043 Capua, Italy
[3] Alenia Aermacchi, I-80038 Naples, Italy
[4] Univ Naples Federico II, Dept Aerosp Engn, I-80100 Naples, Italy
关键词
buckling; CFRP; composites; delamination; lock-in thermography; EMBEDDED DELAMINATION;
D O I
10.1515/secm-2013-0156
中图分类号
TB33 [复合材料];
学科分类号
摘要
The success of composites in automotive, aerospace, and naval applications is mainly related to their aptitude to be tailored to obtain a final product that perfectly fulfills the design requirements. However, during both manufacturing processes and maintenance, some flaws, like delaminations (which may escape simple visual inspection), may be induced in composite structures. The presence of delaminations is of major concern for the load-carrying capability of carbon fiber-reinforced polymer panels. Indeed, delaminations can strongly affect the structural strength and may grow under in-service loads, leading sometimes to catastrophic failures. The aim of this work is to explore the use of lock-in thermography for the monitoring of delamination propagation in composite structures when subjected to generic multiaxial loading conditions. A stiffened composite panel with an embedded skin delamination subjected to compressive loading was taken as a benchmark to assess experimentally the effectiveness of lock-in thermography for monitoring the delamination propagation in situ during the compressive mechanical test. The delamination size as a function of the applied load, observed by lock-in thermography during the execution of the compressive test, was used to validate the results of preliminary numerical computations.
引用
收藏
页码:485 / 492
页数:8
相关论文
共 24 条
[1]  
Abrate S., 1994, APPL MECH REV, V47, P517
[2]  
[Anonymous], 2000, Impact behaviour of fibre-reinforced composite materials and structures
[3]  
*ASTM, 1994, E976 ASTM
[4]  
Beine C, 2010, AER NOV 22 24
[5]  
Busse G., 2001, NONDESTRUCTIVE TESTI, V3, P318
[6]   OPTICAL FIBERS IN NDT - A BRIEF REVIEW OF APPLICATIONS [J].
CULSHAW, B .
NDT INTERNATIONAL, 1985, 18 (05) :265-268
[7]   The effect of defects on the performance of post-buckled CFRP stringer-stiffened panels [J].
Greenhalgh, E ;
Meeks, C ;
Clarke, A ;
Thatcher, J .
COMPOSITES PART A-APPLIED SCIENCE AND MANUFACTURING, 2003, 34 (07) :623-633
[8]  
Greenhalgh E., 2000, ASTM SPECIAL TECHNIC, P49
[9]   Examination of reliability of fibre optic sensors embedded in carbon/epoxy composites [J].
Levin, K ;
Nilsson, S .
THIRD INTERNATIONAL CONFERENCE ON INTELLIGENT MATERIALS - THIRD EUROPEAN CONFERENCE ON SMART STRUCTURES AND MATERIALS, 1996, 2779 :222-229
[10]  
Maldague XPV, 2001, WILEY MICRO, pXV