Puncture resistance and stiffness of nitrile and latex dental examination gloves

被引:14
作者
Patel, HB
Fleming, GJP
Burke, FJT
机构
[1] Univ Birmingham, Sch Dent, Biomat Unit, Birmingham B4 6NN, W Midlands, England
[2] Univ Birmingham, Sch Dent, Primary Dent Care Res Grp, Birmingham B4 6NN, W Midlands, England
关键词
D O I
10.1038/sj.bdj.4811353
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective The aim of the current study was to assess the puncture resistance and stiffness of nitrile and latex dental examination gloves. Methods Puncture resistance was measured by employing an adapted version of ASTM F1342-91 using both a 316 stainless steel puncture probe (0.8 mm diameter) and a dental injection needle (0.45 mm diameter) interfaced to a tensile testing apparatus. Glove specimens (12 cm length, 1.5 cm breadth) were removed for modulus (M100) evaluation by assessing the force required to elongate the specimen to 100% of the original length. Glove samples were also aged to investigate whether puncture resistance and M100 values varied with aging at 70 C for 7 days in an air-circulating oven. Results The nitrile glove types were assessed to have significantly higher puncture resistance compared with the latex glove type when the steel puncture probe was the pentrometer when using the one way analysis of variance (ANOVA) at the 95% significance level. Interestingly the puncture resistance for the latex glove type was significantly higher (P < 0.001) when a dental injection needle was used as the pentrometer compared with the nitrile glove types. The M100 values were significantly higher for the nitrile glove types for which the stiffness increased when the gloves were aged (P < 0.001). Conclusions The higher stiffness values resulted in increased puncture resistance when the nitrile glove specimens were aged irrespective of the pentrometer type. However, the ability of latex to re-seal itself on puncture may be beneficial when considering the protection potential of each glove type against breaches in cross infection. For clinicians that have experienced an adverse reaction to natural latex gloves, the results of the current study indicate that nitrile gloves are available at reasonable cost and offer the clinician comparable resistance to puncture with latex gloves.
引用
收藏
页码:695 / 700
页数:6
相关论文
共 31 条
[1]   Latex exposure and allergy: a survey of general dental practitioners and dental students [J].
Amin, A ;
Palenik, CJ ;
Cheung, SW ;
Burke, FJT .
INTERNATIONAL DENTAL JOURNAL, 1998, 48 (02) :77-83
[2]  
[Anonymous], 1993, MMWR Recomm Rep, V42, P1
[3]  
*ASTM, 1996, F134291 ASTM
[4]  
BALLBACH RL, 1972, J ASSOC OFF ANA CHEM, V55, P1074
[5]  
BURKE FJT, 1990, DENT UPDATE S3, V24
[6]  
Checchi L, 1994, Quintessence Int, V25, P647
[7]   PERCUTANEOUS INJURIES IN DENTISTRY - AN OBSERVATIONAL STUDY [J].
CLEVELAND, JL ;
LOCKWOOD, SA ;
GOOCH, BF ;
MENDELSON, MH ;
CHAMBERLAND, ME ;
VALAURI, DV ;
ROISTACHER, SL ;
SOLOMON, JM ;
MARIANOS, DW .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1995, 126 (06) :745-751
[8]   SKIN PROBLEMS ASSOCIATED WITH ROUTINE WEARING OF PROTECTIVE GLOVES IN DENTAL PRACTICE [J].
FIELD, EA ;
KING, CM .
BRITISH DENTAL JOURNAL, 1990, 169 (09) :281-285
[9]   Biomechanical performance of powder-free examination gloves [J].
Fisher, MD ;
Reddy, VR ;
Williams, FM ;
Lin, KY ;
Thacker, JG ;
Edlich, RF .
JOURNAL OF EMERGENCY MEDICINE, 1999, 17 (06) :1011-1018
[10]  
Fisher MD, 1999, J BIOMED MATER RES, V48, P797, DOI 10.1002/(SICI)1097-4636(1999)48:6<797::AID-JBM6>3.0.CO