X-ray image calibration and its application to clinical orthopedics

被引:21
|
作者
Schumann, Steffen [1 ]
Thelen, Benedikt [1 ]
Ballestra, Steven [1 ]
Nolte, Lutz-P. [1 ]
Buechler, Philippe [1 ]
Zheng, Guoyan [1 ]
机构
[1] Univ Bern, ISTB, CH-3014 Bern, Switzerland
基金
瑞士国家科学基金会;
关键词
X-ray radiograph; Calibration; 3D reconstruction; Orthopedics; Pelvis; Spine; 3D RECONSTRUCTION; CAMERA CALIBRATION; 3-D RECONSTRUCTION; RADIOGRAPHS; SPINE; HIP; MAGNIFICATION; ORIENTATION; ACCURACY; SYSTEM;
D O I
10.1016/j.medengphy.2014.04.001
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
X-ray imaging is one of the most commonly used medical imaging modality. Albeit X-ray radiographs provide important clinical information for diagnosis, planning and post-operative follow-up, the challenging interpretation due to its 2D projection characteristics and the unknown magnification factor constrain the full benefit of X-ray imaging. In order to overcome these drawbacks, we proposed here an easy-to-use X-ray calibration object and developed an optimization method to robustly find correspondences between the 3D fiducials of the calibration object and their 2D projections. In this work we present all the details of this outlined concept. Moreover, we demonstrate the potential of using such a method to precisely extract information from calibrated X-ray radiographs for two different orthopedic applications: post-operative acetabular cup implant orientation measurement and 3D vertebral body displacement measurement during preoperative traction tests. In the first application, we have achieved a clinically acceptable accuracy of below 1 degrees for both anteversion and inclination angles, where in the second application an average displacement of 8.06 +/- 3.71 mm was measured. The results of both applications indicate the importance of using X-ray calibration in the clinical routine. (C) 2014 IPEM. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:968 / 974
页数:7
相关论文
共 50 条
  • [21] XctNet: Reconstruction network of volumetric images from a single X-ray image
    Tan, Zhiqiang
    Li, Jun
    Tao, Huiren
    Li, Shibo
    Hu, Ying
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2022, 98
  • [22] Calibration of medical x-ray apparatus with deformation
    Lu, Jian-Feng
    Yang, Jing-Yu
    Tang, Zhen-Min
    OPTICAL ENGINEERING, 2008, 47 (12)
  • [23] 3D RECONSTRUCTION FROM MULTI-VIEW MEDICAL X-RAY IMAGES - REVIEW AND EVALUATION OF EXISTING METHODS
    Hosseinian, S.
    Arefi, H.
    INTERNATIONAL CONFERENCE ON SENSORS & MODELS IN REMOTE SENSING & PHOTOGRAMMETRY, 2015, 41 (W5): : 319 - 326
  • [24] X-ray imaging spectrometers for Astro-E: Ground calibration in soft X-ray range
    Hayashida, K
    Kitamoto, S
    Miyata, E
    Tsunemi, H
    Yoshita, E
    Kohmura, T
    Mori, K
    Katayama, K
    Katayama, H
    Shouho, M
    Ohta, M
    Dotani, T
    Ozaki, M
    Koyama, K
    Awaki, H
    Tsuru, TG
    Ricker, G
    Bautz, MW
    Foster, R
    Kissel, S
    X-RAY OPTICS, INSTRUMENTS, AND MISSIONS III, 2000, 4012 : 123 - 136
  • [25] Polarized X-ray sources for the 100m beamline calibration of the IXPE X-ray telescopes
    Johnson, Samantha A.
    Baumgartner, Wayne H.
    Bradley, Eric T.
    Moraitis, Christina
    Ramsey, Brian D.
    OPTICS FOR EUV, X-RAY, AND GAMMA-RAY ASTRONOMY IX, 2019, 11119
  • [26] Calibration of the x-ray CCD camera (XIS) for the ASTRO-E in the soft x-ray band
    Katayama, H
    Shouho, M
    Kohmura, T
    Katayama, K
    Ohta, M
    Tsunemi, H
    Kitamoto, S
    Hayashida, K
    Miyata, E
    Yoshita, K
    Koyama, K
    Ricker, G
    Bautz, MW
    Foster, R
    Kissel, S
    Doty, J
    EUV, X-RAY, AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY X, 1999, 3765 : 721 - 728
  • [27] Using tritium and x-ray tubes as x-ray calibration sources for the AXAF CCD imaging spectrometer
    Jones, SE
    Bautz, M
    Kissel, S
    Pivovaroff, M
    EUV, X-RAY, AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY VII, 1996, 2808 : 158 - 169
  • [28] Geometric nonlinear diffusion filter and its application to X-ray imaging
    Michel-Gonzalez, Eric
    Cho, Min Hyoung
    Lee, Soo Yeol
    BIOMEDICAL ENGINEERING ONLINE, 2011, 10
  • [29] Research on calibration model of X-ray thickness gauge
    Xu, G.-D., 1600, Atomic Energy Press (48): : 925 - 929
  • [30] NUMERICAL CALIBRATION PROCEDURE IN X-RAY SPECTROMETRY.
    Ohno, Katsumi
    Transactions of National Research Institute for Metals (Tokyo), 1977, 19 (01): : 32 - 42