X-ray image calibration and its application to clinical orthopedics

被引:21
|
作者
Schumann, Steffen [1 ]
Thelen, Benedikt [1 ]
Ballestra, Steven [1 ]
Nolte, Lutz-P. [1 ]
Buechler, Philippe [1 ]
Zheng, Guoyan [1 ]
机构
[1] Univ Bern, ISTB, CH-3014 Bern, Switzerland
基金
瑞士国家科学基金会;
关键词
X-ray radiograph; Calibration; 3D reconstruction; Orthopedics; Pelvis; Spine; 3D RECONSTRUCTION; CAMERA CALIBRATION; 3-D RECONSTRUCTION; RADIOGRAPHS; SPINE; HIP; MAGNIFICATION; ORIENTATION; ACCURACY; SYSTEM;
D O I
10.1016/j.medengphy.2014.04.001
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
X-ray imaging is one of the most commonly used medical imaging modality. Albeit X-ray radiographs provide important clinical information for diagnosis, planning and post-operative follow-up, the challenging interpretation due to its 2D projection characteristics and the unknown magnification factor constrain the full benefit of X-ray imaging. In order to overcome these drawbacks, we proposed here an easy-to-use X-ray calibration object and developed an optimization method to robustly find correspondences between the 3D fiducials of the calibration object and their 2D projections. In this work we present all the details of this outlined concept. Moreover, we demonstrate the potential of using such a method to precisely extract information from calibrated X-ray radiographs for two different orthopedic applications: post-operative acetabular cup implant orientation measurement and 3D vertebral body displacement measurement during preoperative traction tests. In the first application, we have achieved a clinically acceptable accuracy of below 1 degrees for both anteversion and inclination angles, where in the second application an average displacement of 8.06 +/- 3.71 mm was measured. The results of both applications indicate the importance of using X-ray calibration in the clinical routine. (C) 2014 IPEM. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:968 / 974
页数:7
相关论文
共 50 条
  • [11] Parametric X-ray radiation for calibration of X-ray space telescopes and generation of several X-ray beams
    Shchagin, AV
    Khizhnyak, NA
    Fiorito, RB
    Rule, DW
    Artru, X
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2001, 173 (1-2) : 154 - 159
  • [12] Robustness of Whole Spine Reconstruction using Anterior-Posterior and Lateral Planar X-ray Images
    Kim, Kyungsoo
    Jargalsuren, Sainjargal
    Khuyagbaatar, Batbayar
    Park, Won Man
    Lee, SuKyoung
    Kim, Yoon Hyuk
    INTERNATIONAL JOURNAL OF PRECISION ENGINEERING AND MANUFACTURING, 2018, 19 (02) : 281 - 285
  • [13] 3D shape reconstruction of lumbar vertebra from two X-ray images and a CT model
    Fang, Longwei
    Wang, Zuowei
    Chen, Zhiqiang
    Jian, Fengzeng
    Li, Shuo
    He, Huiguang
    IEEE-CAA JOURNAL OF AUTOMATICA SINICA, 2020, 7 (04) : 1124 - 1133
  • [14] Geometrical Calibration of X-Ray Imaging With RGB Cameras for 3D Reconstruction
    Albiol, Francisco
    Corbi, Alberto
    Albiol, Alberto
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2016, 35 (08) : 1952 - 1961
  • [15] Calibration method for microscale stereo X-ray imaging system
    Kim, Youngjun
    Kim, Wontae
    Park, Sehyung
    Kim, Jong-Hyeong
    INTERNATIONAL JOURNAL OF PRECISION ENGINEERING AND MANUFACTURING, 2012, 13 (06) : 877 - 882
  • [16] PERFORMANCE EVALUATION OF DIAGNOSTIC RADIOLOGY DOSIMETERS IN CLINICAL AND CALIBRATION X-RAY BEAMS
    Hourdakis, Costantine John
    Boziari, Argyro
    Manetou, Aggeliki
    HEALTH PHYSICS, 2010, 98 (05): : 704 - 716
  • [17] Patient positioning with X-ray detector self-calibration for image guided therapy
    Boris Peter Selby
    Georgios Sakas
    Wolfgang-Dieter Groch
    Uwe Stilla
    Australasian Physical & Engineering Sciences in Medicine, 2011, 34 : 391 - 400
  • [18] Film calibration for soft X-ray wavelengths
    Tallents, GJ
    Krishnan, J
    Dwivedi, L
    Neely, D
    Turcu, ICE
    APPLICATIONS OF X RAYS GENERATED FROM LASERS AND OTHER BRIGHT SOURCES, 1997, 3157 : 281 - 290
  • [19] A spectral calibration technique for x-ray CT
    Johnston, Samuel M.
    Badea, Cristian T.
    MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING, 2012, 8313
  • [20] X-ray calibration of the SODART flight telescopes
    Christensen, FE
    Madsen, B
    Hornstrup, A
    Abdali, S
    Frederiksen, P
    Westergaard, NJ
    Polny, J
    BudtzJorgensen, C
    Jonasson, P
    GRAZING INCIDENCE AND MULTILAYER X-RAY OPTICAL SYSTEMS, 1997, 3113 : 294 - 306