Standardized accuracy assessment of the calypso wireless transponder tracking system

被引:30
作者
Franz, A. M. [1 ]
Schmitt, D. [2 ]
Seitel, A. [3 ]
Chatrasingh, M. [4 ]
Echner, G. [2 ]
Oelfke, U. [2 ,5 ,6 ]
Nill, S. [5 ,6 ]
Birkfellner, W. [4 ,7 ]
Maier-Hein, L. [1 ]
机构
[1] DKFZ, Jr Grp Comp Assisted Intervent, D-69121 Heidelberg, Germany
[2] DKFZ, Div Med Phys Radiat Oncol, D-69121 Heidelberg, Germany
[3] Univ British Columbia, Robot & Control Lab, Vancouver, BC V6T 1ZA, Canada
[4] Med Univ Vienna, Ctr Med Phys & Biomed Engn, A-1090 Vienna, Austria
[5] Inst Canc Res, Joint Dept Phys, London SW3 6JB, England
[6] Royal Marsden NHS Fdn Trust, London, England
[7] Med Univ Vienna, Christian Doppler Lab Med Radiat Res Radiat Oncol, A-1090 Vienna, Austria
关键词
transponder tracking; electromagnetic tracking; calypso; computer-assisted interventions; standardized assessment; wireless tracking; ELECTROMAGNETIC TRACKING; LOCALIZATION SYSTEM; TUMOR TRACKING;
D O I
10.1088/0031-9155/59/22/6797
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Electromagnetic (EM) tracking allows localization of small EM sensors in a magnetic field of known geometry without line-of-sight. However, this technique requires a cable connection to the tracked object. A wireless alternative based on magnetic fields, referred to as transponder tracking, has been proposed by several authors. Although most of the transponder tracking systems are still in an early stage of development and not ready for clinical use yet, Varian Medical Systems Inc. (Palo Alto, California, USA) presented the Calypso system for tumor tracking in radiation therapy which includes transponder technology. But it has not been used for computer-assisted interventions (CAI) in general or been assessed for accuracy in a standardized manner, so far. In this study, we apply a standardized assessment protocol presented by Hummel et al (2005 Med. Phys. 32 2371-9) to the Calypso system for the first time. The results show that transponder tracking with the Calypso system provides a precision and accuracy below 1 mm in ideal clinical environments, which is comparable with other EM tracking systems. Similar to other systems the tracking accuracy was affected by metallic distortion, which led to errors of up to 3.2 mm. The potential of the wireless transponder tracking technology for use in many future CAI applications can be regarded as extremely high.
引用
收藏
页码:6797 / 6810
页数:14
相关论文
共 26 条
  • [1] [Anonymous], 2008, Image-Guided Interventions: Technology and Applications. First
  • [2] Accuracy of a wireless localization system for radiotherapy
    Balter, JM
    Wright, JN
    Newell, LJ
    Friemel, B
    Dimmer, S
    Cheng, Y
    Wong, J
    Vertatschitsch, E
    Mate, TP
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 61 (03): : 933 - 937
  • [3] Bittner N, 2014, PRACT RAD O IN PRESS
  • [4] Accuracy of electromagnetic tracking with a prototype field generator in an interventional OR setting
    Bo, Lars Eirik
    Leira, Hakon Olav
    Tangen, Geir Arne
    Hofstad, Erlend Fagertun
    Amundsen, Tore
    Lango, Thomas
    [J]. MEDICAL PHYSICS, 2012, 39 (01) : 399 - 406
  • [5] Comparison of transabdominal ultrasound and electromagnetic transponders for prostate localization
    Foster, Ryan D.
    Solberg, Timothy D.
    Li, Haisen S.
    Kerkhoff, Andrew
    Enke, Charles A.
    Willoughby, Twyla R.
    Kupelian, Patrick A.
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2010, 11 (01): : 57 - 67
  • [6] Electromagnetic tracking for US-guided interventions: standardized assessment of a new compact field generator
    Franz, A. M.
    Maerz, K.
    Hummel, J.
    Birkfellner, W.
    Bendl, R.
    Delorme, S.
    Schlemmer, H. -P.
    Meinzer, H. -P.
    Maier-Hein, L.
    [J]. INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2012, 7 (06) : 813 - 818
  • [7] Electromagnetic Tracking in Medicine-A Review of Technology, Validation, and Applications
    Franz, Alfred M.
    Haidegger, Tamas
    Birkfellner, Wolfgang
    Cleary, Kevin
    Peters, Terry M.
    Maier-Hein, Lena
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2014, 33 (08) : 1702 - 1725
  • [8] EMI Shielding: Methods and Materials-A Review
    Geetha, S.
    Kumar, K. K. Satheesh
    Rao, Chepuri R. K.
    Vijayan, M.
    Trivedi, D. C.
    [J]. JOURNAL OF APPLIED POLYMER SCIENCE, 2009, 112 (04) : 2073 - 2086
  • [9] CLOSED-FORM SOLUTION OF ABSOLUTE ORIENTATION USING UNIT QUATERNIONS
    HORN, BKP
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1987, 4 (04): : 629 - 642
  • [10] Design and application of an assessment protocol for electromagnetic tracking systems
    Hummel, JB
    Bax, MR
    Figl, ML
    Kang, Y
    Maurer, C
    Birkfellner, WW
    Bergmann, H
    Shahidi, R
    [J]. MEDICAL PHYSICS, 2005, 32 (07) : 2371 - 2379