Double-Lumen Endotracheal Tube Placement: Knowing Depth of Insertion Firsthand May Make a Difference

被引:6
作者
Essandoh, Michael [1 ]
Andritsos, Michael [1 ]
机构
[1] Ohio State Univ, Dept Anesthesiol, Wexner Med Ctr, Columbus, OH 43210 USA
关键词
MAINSTEM BRONCHIAL DIAMETER; TRACHEAL DIAMETER; THORACIC-SURGERY; LUNG ISOLATION; SIZE; PATIENT; BLOCKER;
D O I
10.1053/j.jvca.2017.11.031
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
引用
收藏
页码:860 / 862
页数:3
相关论文
共 20 条
[1]   Practice patterns in choice of left double-lumen tube size for thoracic surgery [J].
Amar, David ;
Desiderio, Dawn P. ;
Heerdt, Paul M. ;
Kolker, Anne C. ;
Zhang, Hao ;
Thaler, Howard T. .
ANESTHESIA AND ANALGESIA, 2008, 106 (02) :379-383
[2]   Tracheal diameter predicts double-lumen tube size: A method for selecting left double-lumen tubes [J].
Brodsky, JB ;
Macario, A ;
Mark, JBD .
ANESTHESIA AND ANALGESIA, 1996, 82 (04) :861-864
[3]   Tracheal width and teft double-lumen tube size: a formula to estimate teft-bronchial width [J].
Brodsky, JB ;
Lemmens, HJM .
JOURNAL OF CLINICAL ANESTHESIA, 2005, 17 (04) :267-270
[4]   Lung isolation in the morbidly obese patient: a comparison of a left-sided double-lumen tracheal tube with the Arndt wire-guided blocker [J].
Campos, J. H. ;
Hallam, E. A. ;
Ueda, K. .
BRITISH JOURNAL OF ANAESTHESIA, 2012, 109 (04) :630-635
[5]   Training in placement of the left-sided double-lumen tube among non-thoracic anaesthesiologists: intubation model simulator versus computer-based digital video disc, a randomised controlled trial [J].
Campos, Javier H. ;
Hallam, Ezra A. ;
Ueda, Kenichi .
EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2011, 28 (03) :169-174
[6]   Devices for lung isolation used by anesthesiologists with limited thoracic experience -: Comparison of double-lumen endotracheal tube, Univent® torque control blocker, and Arndt wire-guided endobronchial Blocker® [J].
Campos, JH ;
Hallam, EA ;
Van Natta, T ;
Kernstine, KH .
ANESTHESIOLOGY, 2006, 104 (02) :261-266
[7]   Predicting the size of a double-lumen endobronchial tube based on tracheal diameter [J].
Chow, MYH ;
Liam, BL ;
Lew, TWK ;
Chelliah, RY ;
Ong, BC .
ANESTHESIA AND ANALGESIA, 1998, 87 (01) :158-160
[8]   Is flexible bronchoscopy necessary to confirm the position of double-lumen tubes before thoracic surgery? [J].
de Bellis, Mario ;
Accardo, Rosanna ;
Di Maio, Massimo ;
Lamanna, Carmine ;
Rossi, Giovanni Battista ;
Pace, Maria Caterina ;
Romano, Vincenzo ;
Rocco, Gaetano .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2011, 40 (04) :912-916
[9]   Evaluation of an approach to choosing a left double-lumen tube size based on chest computed tomographic scan measurement of left mainstem bronchial diameter [J].
Hannallah, M ;
Benumof, JL ;
Silverman, PM ;
Kelly, LC ;
Lea, D .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 1997, 11 (02) :168-171
[10]   THE RELATIONSHIP BETWEEN LEFT MAINSTEM BRONCHIAL DIAMETER AND PATIENT SIZE [J].
HANNALLAH, MS ;
BENUMOF, JL ;
RUTTIMANN, UE .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 1995, 9 (02) :119-121