In Situ Visualization of Tears on Contact Lens Using Ultra High Resolution Optical Coherence Tomography

被引:52
作者
Wang, Jianhua [1 ]
Jiao, Shuliang
Ruggeri, Marco
Abou Shousha, Mohammed
Chen, Qi [2 ]
机构
[1] Univ Miami, Miller Sch Med, Bascom Palmer Eye Inst, Miami, FL 33136 USA
[2] Wenzhou Med Coll, Sch Ophthalmol & Optometry, Wenzhou, Zhejiang, Peoples R China
来源
EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE | 2009年 / 35卷 / 02期
关键词
Tear dynamics; Optical coherence tomography; Contact lens; VIVO;
D O I
10.1097/ICL.0b013e31819579f2
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objective: To demonstrate. the capability of directly visualizing the tear film on contact lenses using optical coherence tomography (OCT). Methods: Six eyes of three healthy subjects wearing PureVision and ACUVUE Advance soft and Boston RGP hard contact lenses were imaged with a custom built, high speed, ultra-high resolution spectral domain optical coherence tomograph. Refresh Liquigel was used to demonstrate the effect of artificial tears on the tear film. Results: Ultra high resolution images of the pre- and post-lens films were directly visualized when each lens was inserted onto the eye. After the instillation of artificial tears during lens wear, the tear film was thicker. The post-lens tear film underneath the lens edge was clearly shown. Interactions between the lens edges and the ocular surface were obtained for each of the lens types and base curves. With a contrast enhancement agent, tear menisci on the contact lenses around the upper and lower eyelids were highlighted. With hard contact lenses, the tear film was visualized clearly and changed after a blink when the lens was pulled up by the lid. Conclusions: Ultra-high resolution OCT is a potentially promising technique for imaging tears around contact lenses. This successful demonstration of in situ post-lens tear film imaging suggests that OCT could open a new era in studying tear dynamics during contact lens wear. The novel method may lead to new ways of evaluating contact lens fitting.
引用
收藏
页码:44 / 49
页数:6
相关论文
共 13 条
[1]  
CAFFERY B, 1996, OPTOMETRY VISION SCI, V73, P109
[2]  
Caffery BE, 1998, ADV EXP MED BIOL, V438, P805
[3]   In vivo corneal high-speed, ultra-high-resolution optical coherence tomography [J].
Christopoulos, Viki ;
Kagemann, Larry ;
Wollstein, Gadi ;
Ishikawa, Hi. Roshi ;
Gabriele, Michelle L. ;
Wojtkowski, Maciej ;
Srinivasan, Vivek ;
Fujimoto, James G. ;
Duker, Jay S. ;
Dhaliwal, Deepinder K. ;
Schuman, Joel S. .
ARCHIVES OF OPHTHALMOLOGY, 2007, 125 (08) :1027-1035
[4]   MICROMETER-SCALE RESOLUTION IMAGING OF THE ANTERIOR EYE IN-VIVO WITH OPTICAL COHERENCE TOMOGRAPHY [J].
IZATT, JA ;
HEE, MR ;
SWANSON, EA ;
LIN, CP ;
HUANG, D ;
SCHUMAN, JS ;
PULIAFITO, CA ;
FUJIMOTO, JG .
ARCHIVES OF OPHTHALMOLOGY, 1994, 112 (12) :1584-1589
[5]   Spectral optical coherence tomography in video-rate and 3D imaging of contact lens wear [J].
Kaluzny, Bartlomiej J. ;
Fojt, Wojciech ;
Szkulmowska, Anna ;
Bajraszewski, Tomasz ;
Wojtkowski, Maciej ;
Kowalczyk, Andrzej .
OPTOMETRY AND VISION SCIENCE, 2007, 84 (12) :1104-1109
[6]   Spectral optical coherence tomography: a new imaging technique in contact lens practice [J].
Kaluzny, BJ ;
Kaluzny, JJ ;
Szkulmowska, A ;
Gorczynska, I ;
Szkulmowski, M ;
Bajraszewski, T ;
Targowski, P ;
Kowalczyk, A .
OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2006, 26 (02) :127-132
[7]  
Mountford John, 2005, Clin Exp Optom, V88, P33
[8]  
Muscat S, 2002, INVEST OPHTH VIS SCI, V43, P490
[9]   Effect of blinking on tear dynamics [J].
Palakuru, Jayachandra R. ;
Wang, Jianhua ;
Aquavella, James V. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2007, 48 (07) :3032-3037
[10]   Visualization of aqueous shunt position and patency using anterior segment optical coherence tomography [J].
Sarodia, Usman ;
Sharkawi, Eamon ;
Hau, Scott ;
Barton, Keith .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2007, 143 (06) :1054-1056