Electrocatalysis and amperometric detection of alditols and sugars at a gold-nickel composite electrode in anion-exchange chromatography

被引:23
作者
Casella, IG [1 ]
Guascito, MR [1 ]
Cataldi, TRI [1 ]
机构
[1] Univ Basilicata, Dipartimento Chim, I-85100 Potenza, Italy
关键词
D O I
10.1016/S0003-2670(99)00420-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel Au-Ni composite electrode prepared by cathodic precipitation/deposition of nickel hydroxide on the gold surface was characterised. The resulting composite electrode was evaluated as an amperometric sensor in flow injection analysis and anion-exchange chromatography for the quantitation of alditols and simple carbohydrates. Constant potential detection at +0.6V vs Ag/AgCl and a pulsed detection mode were employed, and their applicability and usefulness discussed. The detection Limits (S/N = 3) for all investigated compounds, in both modes of detection, ranged between 1.5 and 7.5 pmol injected. Linear dynamic ranges spanned over four and three orders of magnitude when the composite electrode was used in the DC or pulsed mode. The main advantage of the Au-Ni composite electrode is that detection selectivity can be tailored by the choice of the detection mode and by the polarisation potential. As an example, we show how to detect common carbohydrates in tea powder using the constant potential detection mode. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:153 / 160
页数:8
相关论文
共 50 条
[21]   MONOSACCHARIDE ANALYSIS OF GLYCOCONJUGATES BY ANION-EXCHANGE CHROMATOGRAPHY WITH PULSED AMPEROMETRIC DETECTION [J].
HARDY, MR ;
TOWNSEND, RR ;
LEE, YC .
ANALYTICAL BIOCHEMISTRY, 1988, 170 (01) :54-62
[22]   DETERMINATION OF CYCLIC GLUCANS BY ANION-EXCHANGE CHROMATOGRAPHY WITH PULSED AMPEROMETRIC DETECTION [J].
KOIZUMI, K ;
KUBOTA, Y ;
TANIMOTO, T ;
OKADA, Y .
JOURNAL OF CHROMATOGRAPHY, 1988, 454 :303-310
[23]   Direct determination of free amino acids and sugars in green tea by anion-exchange chromatography with integrated pulsed amperometric detection [J].
Ding, YS ;
Yu, H ;
Mou, SF .
JOURNAL OF CHROMATOGRAPHY A, 2002, 982 (02) :237-244
[24]   DETERMINATION OF XYLOSE OLIGOMERS AND MONOSACCHARIDES BY ANION-EXCHANGE CHROMATOGRAPHY WITH PULSED AMPEROMETRIC DETECTION [J].
MOU, SF ;
SUN, Q ;
LU, DP .
JOURNAL OF CHROMATOGRAPHY, 1991, 546 (1-2) :289-295
[25]   PULSED AMPEROMETRIC DETECTION OF AMINO-ACIDS SEPARATED BY ANION-EXCHANGE CHROMATOGRAPHY [J].
MARTENS, DA ;
FRANKENBERGER, WT .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1992, 15 (03) :423-439
[26]   Nickel-titanium alloy electrodes for stable amperometric detection of underivatized amino acids in anion-exchange chromatography [J].
Sato, K ;
Jin, JY ;
Takeuchi, T ;
Miwa, T ;
Takekoshi, Y ;
Kanno, S ;
Kawase, S .
TALANTA, 2001, 53 (05) :1037-1044
[27]   DETERMINATION OF SUGARS IN POLYSACCHARIDE HYDROLYSATES BY ANION-EXCHANGE CHROMATOGRAPHY [J].
VANBILJON, PL ;
OLIVIER, SP .
JOURNAL OF CHROMATOGRAPHY, 1989, 473 (01) :305-309
[28]   Maple syrup authenticity analysis by anion-exchange liquid chromatography with pulsed amperometric detection [J].
Stuckel, JG ;
Low, NH .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1995, 43 (12) :3046-3051
[29]   DETERMINATION OF AMINOSACCHARIDES BY HIGH-PERFORMANCE ANION-EXCHANGE CHROMATOGRAPHY WITH PULSED AMPEROMETRIC DETECTION [J].
MARTENS, DA ;
FRANKENBERGER, WT .
TALANTA, 1991, 38 (03) :245-251
[30]   DETERMINATION OF SACCHARIDES BY HIGH-PERFORMANCE ANION-EXCHANGE CHROMATOGRAPHY WITH PULSED AMPEROMETRIC DETECTION [J].
MARTENS, DA ;
FRANKENBERGER, WT .
CHROMATOGRAPHIA, 1990, 29 (1-2) :7-12