Determination of phosphorus, sulfur and the halogens using high-temperature molecular absorption spectrometry in flames and furnaces-A review

被引:141
作者
Welz, Bernhard [1 ]
Lepri, Fabio G. [1 ]
Araujo, Rennan G. O. [1 ]
Ferreira, Sergio L. C. [2 ]
Huang, Mao-Dong [3 ]
Okruss, Michael [3 ]
Becker-Ross, Helmut [3 ]
机构
[1] Univ Fed Santa Catarina, Dept Quim, BR-88040900 Florianopolis, SC, Brazil
[2] Univ Fed Bahia, Inst Quim, BR-40170290 Salvador, BA, Brazil
[3] ISAS Inst Analyt Sci, Dept Interface Spect, D-12489 Berlin, Germany
关键词
Molecular absorption spectrometry; Non-metals determination; Phosphorus; Sulfur; Halogens; RAY-FLUORESCENCE SPECTROMETRY; LIQUID-LIQUID-EXTRACTION; GRAPHITE-FURNACE; CONTINUUM-SOURCE; ELECTROTHERMAL VOLATILIZATION; SPECTROPHOTOMETRIC DETERMINATION; BACKGROUND-CORRECTION; CARBON MONOSULFIDE; INJECTION-ANALYSIS; MASS-SPECTROMETRY;
D O I
10.1016/j.aca.2009.06.029
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The literature about the investigation of molecular spectra of phosphorus, sulfur and the halogens in flames and furnaces, and the use of these spectra for the determination of these non-metals has been reviewed. Most of the investigations were carried out using conventional atomic absorption spectrometers, and there were in essence two different approaches. In the first one, dual-channel spectrometers with a hydrogen or deuterium lamp were used, applying the two-line method for background correction; in the second one, a line source was used that emitted an atomic line, which overlapped with the molecular spectrum. The first approach had the advantage that any spectral interval could be accessed, but it was susceptible to spectral interference; the second one had the advantage that the conventional background correction systems could be used to minimize spectral interferences, but had the problem that an atomic line had to be found, which was overlapping sufficiently well with the maximum of the molecular absorption spectrum. More recently a variety of molecular absorption spectra were investigated using a low-resolution polychromator with a CCD array detector, but no attempt was made to use this approach for quantitative determination of non-metals. The recent introduction and commercial availability of high-resolution continuum source atomic absorption spectrometers is offering completely new possibilities for molecular absorption spectrometry and its use for the determination of non-metals. The use of a high-intensity continuum source together with a high-resolution spectrometer and a CCD array detector makes possible selecting the optimum wavelength for the determination and to exclude most spectral interferences. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:137 / 148
页数:12
相关论文
共 118 条
[21]   Investigation of artifacts caused by deuterium background correction in the determination of phosphorus by electrothermal atomization using high-resolution continuum source atomic absorption spectrometry [J].
Dessuy, Morgana B. ;
Vale, Maria Goreti R. ;
Lepri, Fabio G. ;
Borges, Daniel L. G. ;
Welz, Bernhard ;
Silva, Marcia M. ;
Heitmann, Uwe .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2008, 63 (02) :337-348
[22]   Investigation of phosphorus atomization using high-resolution continuum source electrothermal atomic absorption spectrometry [J].
Dessuy, Morgana B. ;
Vale, Maria Goreti R. ;
Lepri, Fabio G. ;
Welz, Bernhard ;
Heitmann, Uwe .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2007, 62 (05) :429-434
[23]   MOLECULAR ABSORPTION SPECTROMETRY WITH ELECTROTHERMAL VOLATILIZATION IN A GRAPHITE TUBE .4. DETERMINATION OF BROMIDE TRACES BY MOLECULAR ABSORPTION OF INBR AND TLBR [J].
DITTRICH, K ;
SCHNEIDER, S .
ANALYTICA CHIMICA ACTA, 1980, 115 (MAR) :189-200
[24]   MOLECULAR ABSORPTION SPECTROMETRY WITH ELECTROTHERMAL VOLATILIZATION IN A GRAPHITE TUBE .5. DETERMINATION OF IODIDE TRACES BY MOLECULAR ABSORPTION OF TLI [J].
DITTRICH, K ;
SCHNEIDER, S .
ANALYTICA CHIMICA ACTA, 1980, 115 (MAR) :201-209
[25]   MOLECULAR ABSORPTION SPECTROMETRY WITH ELECTROTHERMAL VOLATILIZATION IN A GRAPHITE TUBE .8. A STUDY OF MOLECULAR ABSORPTION OF GES AND DETERMINATION OF SULFUR SPECIES VIA GES [J].
DITTRICH, K ;
VORBERG, B .
ANALYTICA CHIMICA ACTA, 1983, 152 (SEP) :149-161
[26]  
Dittrich K., 1980, Progress in Analytical Atomic Spectroscopy, V3, P209
[27]   DETERMINATION OF SOME NONMETALS BY USING DIATOMIC MOLECULAR ABSORBANCE IN A HOT GRAPHITE-FURNACE [J].
DITTRICH, K ;
VORBERG, B ;
FUNK, J ;
BEYER, V .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1984, 39 (2-3) :349-363
[29]   MOLECULAR ABSORPTION SPECTROMETRY BY ELECTROTHERMAL EVAPORATION IN THE GRAPHITE-FURNACE .10. DETERMINATION OF CHLORIDE TRACES BY ALCL MA IN GRAPHITE CUVETTES AFTER LIQUID LIQUID EXTRACTION OF CHLORIDE WITH TRIPHENYLTIN HYDROXIDE [J].
DITTRICH, K ;
SPIVAKOV, BY ;
SHKINEV, VM ;
VOROBEVA, GA .
TALANTA, 1984, 31 (05) :341-345