Partial Discharge Analysis of SF6/N2 Gas Mixture Filled MV Circuit Breaker Using Time-Frequency Map Clustering Technique

被引:0
|
作者
Yuvaraj, R. [1 ]
Chandrasekar, S. [2 ]
机构
[1] Gnanamani Coll Technol, Dept Elect & Elect Engn, Namakkal, India
[2] Sona Coll Technol, Dept Elect & Elect Engn, SonaPERT R&D Ctr, Salem 636005, India
关键词
Circuit breaker; Partial discharge; Gas insulation; Time– frequency map; Clustering technique; SF6; SYSTEMS;
D O I
10.1007/s42835-020-00597-1
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Breakdown of gas insulated switchgears due to partial discharges (PD) is a major threat for the safe and reliable operation of power system network. In recent times, PD based diagnostics has been widely adopted by electrical utilities in order to evaluate the health of high voltage insulation system. However, very few reports are only available on the PD characteristics of gas insulated medium voltage (MV) circuit breaker prototypes, in particular with mixture of gases, over a wide range of pressure and voltage stress. Deep analysis of nature of PD signals in mixture of gas insulation and its time-frequency characteristics is important in order to develop efficient online condition monitoring systems for circuit breakers. This paper is aimed at the analysis of PD characteristics of a 22 kV MV circuit breaker prototype filled with SF6/N-2 gas mixtures using time-frequency (T-F) mapping and clustering technique. PD tests are carried out at different gas pressures (1-5 bar) and at different gas mixture ratios. Important PD parameters such as PD inception voltage, phase resolved PD (PRPD) pattern and PD repetition rate are evaluated. Clustering analysis of PD signals from the time-frequency mapping is carried out and formation of three different clusters consisting of short, long and repetitive PD pulses is identified. Online real time monitoring of individual cluster density will be helpful to understand the degradation of gas insulation of circuit breakers. Keeping in mind the minimal usage of SF6 gas, from the results, it is noted that 10% SF6 gas can be mixed with 90% N-2 at 3 bar pressure to get satisfactory PD performance of a 22 kV medium voltage circuit breaker.
引用
收藏
页码:499 / 507
页数:9
相关论文
共 50 条
  • [41] Insulation properties of CO2/N2 gas mixture with a small amount of SF6
    Ohtsuka, S
    Koumura, M
    Cho, M
    Hashimoto, Y
    Nakamura, M
    Hikita, M
    GASEOUS DIELECTRICS IX, 2001, : 295 - 300
  • [42] Step propagation mechanism of impulse creepage discharge in N2/SF6 gas mixtures
    Okubo, H
    Shibutani, D
    Hayakawa, N
    GASEOUS DIELECTRICS IX, 2001, : 339 - 344
  • [43] Evaluation of pressure-temperature swing adsorption for sulfur hexafluoride (SF6) recovery from SF6 and N2 gas mixture
    Wan-Seon Cho
    Kwang-Hoon Lee
    Hyang-Ja Chang
    Wansoo Huh
    Heock-Hoi Kwon
    Korean Journal of Chemical Engineering, 2011, 28 : 2196 - 2201
  • [44] Evaluation of pressure-temperature swing adsorption for sulfur hexafluoride (SF6) recovery from SF6 and N2 gas mixture
    Cho, Wan-Seon
    Lee, Kwang-Hoon
    Chang, Hyang-Ja
    Huh, Wansoo
    Kwon, Heock-Hoi
    KOREAN JOURNAL OF CHEMICAL ENGINEERING, 2011, 28 (11) : 2196 - 2201
  • [45] Partial Discharge Initial Characteristics of SF6/N2 Mixture in Extremely Inhomogeneous Electric Field under DC High Voltage
    Pang P.
    Sun Z.
    Zhang Q.
    Hou Z.
    Zhang X.
    Sun S.
    Li J.
    Hsi-An Chiao Tung Ta Hsueh/Journal of Xi'an Jiaotong University, 2019, 53 (04): : 44 - 50
  • [46] Discrimination Technique of Streamer and Leader Type of Partial Discharge in SF6 Gas Using UHF Method
    Hanai, Masahiro
    Suzuki, Keisuke
    Mizuno, Ryunosuke
    Kojima, Hiroki
    Hayakawa, Naoki
    Okubo, Hitoshi
    PROCEEDINGS OF 2012 IEEE INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS (IEEE CMD 2012), 2012, : 301 - 304
  • [47] Ultra fast marx generator of N2, SF6, N 2-SF6 mixture gas based on research output characteristics
    Doo, Jin-Suk
    Han, Seung-Moon
    Huh, Chang-Su
    Choi, Jin-Soo
    Transactions of the Korean Institute of Electrical Engineers, 2010, 59 (10): : 1850 - 1855
  • [48] Insulation Integrity of Metallic Particles in a Gas Insulated Busduct using SF6 and N2 Gas Mixture under the Influence of Power frequency and Impulse Voltages
    Nagabhushan, P.
    Amarnath, J.
    Subbarayudu, D.
    2011 14TH INTERNATIONAL SYMPOSIUM ON ELECTRETS (ISE), 2011, : 195 - +
  • [49] LOW-FREQUENCY WAVES IN SF6 POSITIVE COLUMNS DILUTED WITH N2 GAS
    ISHIKAWA, I
    KONDO, K
    NAKATANI, Y
    SUGANOMATA, S
    MATSUMOTO, M
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1993, 32 (02): : 965 - 966
  • [50] Influence of microwater on the decomposition of SF6/N2 gas mixture insulating media in overheating faults
    Chen, Haoxin
    Zeng, Xiaosong
    Xiao, Yanfeng
    Li, Haotian
    Yao, Qiang
    Zeng, Fuping
    AIP ADVANCES, 2024, 14 (01)