Breakdown of gas insulated switchgears due to partial discharges (PD) is a major threat for the safe and reliable operation of power system network. In recent times, PD based diagnostics has been widely adopted by electrical utilities in order to evaluate the health of high voltage insulation system. However, very few reports are only available on the PD characteristics of gas insulated medium voltage (MV) circuit breaker prototypes, in particular with mixture of gases, over a wide range of pressure and voltage stress. Deep analysis of nature of PD signals in mixture of gas insulation and its time-frequency characteristics is important in order to develop efficient online condition monitoring systems for circuit breakers. This paper is aimed at the analysis of PD characteristics of a 22 kV MV circuit breaker prototype filled with SF6/N-2 gas mixtures using time-frequency (T-F) mapping and clustering technique. PD tests are carried out at different gas pressures (1-5 bar) and at different gas mixture ratios. Important PD parameters such as PD inception voltage, phase resolved PD (PRPD) pattern and PD repetition rate are evaluated. Clustering analysis of PD signals from the time-frequency mapping is carried out and formation of three different clusters consisting of short, long and repetitive PD pulses is identified. Online real time monitoring of individual cluster density will be helpful to understand the degradation of gas insulation of circuit breakers. Keeping in mind the minimal usage of SF6 gas, from the results, it is noted that 10% SF6 gas can be mixed with 90% N-2 at 3 bar pressure to get satisfactory PD performance of a 22 kV medium voltage circuit breaker.
引用
收藏
页码:499 / 507
页数:9
相关论文
共 17 条
  • [1] Partial Discharge Analysis of SF6/N2 Gas Mixture Filled MV Circuit Breaker Using Time–Frequency Map Clustering Technique
    R. Yuvaraj
    S. Chandrasekar
    Journal of Electrical Engineering & Technology, 2021, 16 : 499 - 507
  • [2] Influence of SF6/N2 Gas Mixture Ratios on the Lightning Streamer Propagation Characteristics of 22 kV MV Circuit Breaker
    Gandhi, R.
    Chandrasekar, S.
    Nagarajan, C.
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2018, 13 (04) : 1662 - 1671
  • [3] Partial Discharge Characteristics of the Surface Discharge in SF6/N2 of the Mixed Gas Under DC Voltage
    Hou Z.
    Guo R.
    Li J.
    Li, Junhao (junhaoli@mail.xjtu.edu.cn), 1600, Chinese Machine Press (35): : 3087 - 3096
  • [4] Partial Discharge Characteristics of SF6 and SF6/N2 in Nonuniform Electric Field Under Negative DC Voltage
    Han, Xutao
    Zhang, Xuanrui
    Wang, Haotian
    Sun, Yuan
    Zhou, Yang
    Li, Junhao
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2023, 30 (01) : 131 - 138
  • [5] Decomposition Characteristics of SF6/N2 Under Partial Discharge of Different Degrees
    Li, Chen
    Tang, Ju
    Zhao, Zhiqiang
    Li, Haotian
    Miao, Yulong
    Zeng, Fuping
    IEEE ACCESS, 2020, 8 : 192312 - 192319
  • [6] Temperature Effect on the Insulation Performance of SF6/N2 Gas Mixture at a Constant Volume
    Zheng, Yu
    Zhou, Wenjun
    Yang, Shuai
    Qiao, Shengya
    Huang, Jiarui
    Qin, Zhaoyu
    2016 IEEE INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATION (ICHVE), 2016,
  • [7] Discrimination Technique of Streamer and Leader Type of Partial Discharge in SF6 Gas Using UHF Method
    Hanai, Masahiro
    Suzuki, Keisuke
    Mizuno, Ryunosuke
    Kojima, Hiroki
    Hayakawa, Naoki
    Okubo, Hitoshi
    PROCEEDINGS OF 2012 IEEE INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS (IEEE CMD 2012), 2012, : 301 - 304
  • [8] Insulation properties of a CO2/N2 50% SF6 gas mixture in a nonuniform field
    Ohtsuka, S
    Nagara, S
    Koumura, M
    Hashimoto, Y
    Nakamura, M
    Hikita, M
    ELECTRICAL ENGINEERING IN JAPAN, 2002, 140 (03) : 34 - 43
  • [9] Impulse partial discharge characteristics and their mechanisms under non-uniform electric field in N2/SF6 gas mixtures
    Hayakawa, N
    Yoshitake, Y
    Koshino, N
    Ueda, T
    Okubo, H
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2005, 12 (05) : 1035 - 1042
  • [10] Diagnosis potential of different partial discharge features of diverse PD defects in N2/SF6 mixtures
    Aschenbrenner, D
    Kranz, HG
    PROCEEDINGS OF THE 7TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1-3, 2003, : 69 - 72