Evaluation of Milled Titanium versus Laser Sintered Co-Cr Abutments on the Marginal Misfit in Internal Implant-Abutment Connection

被引:14
|
作者
Gonzalo, Esther [1 ]
Vizoso, Beatriz [1 ]
Lopez-Suarez, Carlos [1 ]
Diaz, Pedro [1 ]
Pelaez, Jesus [1 ]
Suarez, Maria J. [1 ]
机构
[1] Univ Complutense Madrid, Fac Odontol, Dept Conservat Dent & Bucofacial Prosthesis, Madrid 28040, Spain
关键词
Co-Cr abutment; laser sintering; CAD; CAM milled; marginal misfit; implant-abutment interface; FIXED DENTAL PROSTHESES; FRACTURE-RESISTANCE; ZIRCONIA ABUTMENTS; SEALING CAPABILITY; FOLLOW-UP; FIT; ACCURACY; CROWNS; SURVIVAL; INFLAMMATION;
D O I
10.3390/ma13214873
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The precision of fit at the implant-abutment connection is an important criterion for the clinical success of restorations and implants. Several factors are involved among which are the abutment materials and manufacturing techniques. The aim of this study was to investigate the effect of two materials and methods of manufacturing implant abutments, milled titanium versus laser sintered Co-Cr, on the marginal misfit at the implant-abutment interface. Scanning electron microscopes (SEM) were used to geometrically measure the marginal vertical discrepancy of a total of 80 specimens, classified into eight categories, according to the implant system and abutment. The data were statistically analyzed by Student's paired t test, one-way and two-way ANOVA with the Bonferroni-Holm correction at the significance level of p = 0.05. Milled titanium abutments demonstrated the lowest misfit values in the implant systems analyzed. The marginal fit of all the groups was within the clinically acceptable range for implant prostheses.
引用
收藏
页码:1 / 12
页数:12
相关论文
共 28 条
  • [1] Evaluation of the influence of connection configuration on the implant-abutment interface vertical misfit of original milled titanium and laser-sintered cobalt-chromium abutments
    Diaz, Pedro
    Vizoso, Beatriz
    Lopez-Suarez, Carlos
    Gonzalo, Esther
    Mosaddad, Seyed Ali
    Suarez, Maria J.
    CLINICAL ORAL INVESTIGATIONS, 2025, 29 (01)
  • [2] Evaluation of Marginal and Internal Fit at Implant-Abutment Interface of Original and Compatible Nonoriginal Abutments
    Berberi, Antoine
    Tehini, Georges
    Hjeij, Bouchra
    Aoun, Georges
    Journal of Long-Term Effects of Medical Implants, 2022, 32 (03) : 21 - 28
  • [3] Bending Moments and Types of Failure of Zirconia and Titanium Abutments with Internal Implant-Abutment Connections: A Laboratory Study
    Leutert, Christian R.
    Stawarczyk, Bogna
    Truninger, Thomas C.
    Haemmerle, Christoph H. F.
    Sailer, Irena
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2012, 27 (03) : 505 - 512
  • [4] In Vitro Study of the Influence of the Type of Connection on the Fracture Load of Zirconia Abutments with Internal and External Implant-Abutment Connections
    Sailer, Irena
    Sailer, Thomas
    Stawarczyk, Bogna
    Jung, Ronald Ernst
    Haemmerle, Christoph Hans Franz
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2009, 24 (05) : 850 - 858
  • [5] Tactile misfit detection ability at the implant-abutment interface of internal connection dental implants: an in-vitro study
    Molinero-Mourelle, Pedro
    Peter, Lukas
    Gaviria, Ana Sol
    Fonseca, Manrique
    Schimmel, Martin
    Katsoulis, Joannis
    ACTA ODONTOLOGICA SCANDINAVICA, 2023, 81 (08) : 591 - 596
  • [6] Bending moments of zirconia and titanium abutments with internal and external implant-abutment connections after aging and chewing simulation
    Truninger, Thomas C.
    Stawarczyk, Bogna
    Leutert, Christian R.
    Sailer, Thomas R.
    Haemmerle, Christoph H. F.
    Sailer, Irena
    CLINICAL ORAL IMPLANTS RESEARCH, 2012, 23 (01) : 12 - 18
  • [7] Influence of Implant-Abutment Connection Biomechanics on Biological Response: A Literature Review on Interfaces between Implants and Abutments of Titanium and Zirconia
    Choi, Sunyoung
    Kang, Young Suk
    Yeo, In-Sung Luke
    PROSTHESIS, 2023, 5 (02): : 527 - 538
  • [8] Mechanical Outcomes, Microleakage, and Marginal Accuracy at the Implant-Abutment Interface of Original versus Nonoriginal Implant Abutments: A Systematic Review of In Vitro Studies
    Tallarico, Marco
    Fiorellini, Joseph
    Nakajima, Yasushi
    Omori, Yuki
    Takahisa, Iida
    Canullo, Luigi
    BIOMED RESEARCH INTERNATIONAL, 2018, 2018
  • [9] Stereomicroscopic Evaluation of Marginal Fit of Premachined and Castable Abutments at Implant Abutment Connection Interface - An In Vitro Study
    Kumar, Prince
    Singh, Swarndeep
    Mishra, Sunil Kumar
    JOURNAL OF THE SCIENTIFIC SOCIETY, 2023, 50 (02) : 254 - 258
  • [10] Evaluation of the Mechanical Behavior and Marginal Accuracy of Stock and Laser-Sintered Implant Abutments
    Alonso-Perez, Raquel
    Bartolome, Jose F.
    Ferreiroa, Alberto
    Salido, Maria P.
    Pradies, Guillermo
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2017, 30 (02) : 136 - 138