A Monte Carlo simulation study on the effectiveness of electron filters designed for telecobalt radiation therapy treatment

被引:1
|
作者
Shukla, R. [1 ]
Patel, N. P. [2 ]
Yadav, H. P. [1 ]
Kausha, V [2 ]
机构
[1] GGS Med Coll, Dept Radiotherapy, Faridkot, India
[2] Pt BD Sharma Post Grad Inst Med Sci, Dept Radiotherapy, Rohtak, Haryana, India
来源
INTERNATIONAL JOURNAL OF RADIATION RESEARCH | 2019年 / 17卷 / 02期
关键词
Telecobalt; electron contamination; electron filters; surface dose; Monte Carlo simulation; CONTAMINATION; CO-60; LEAD; BEAM;
D O I
10.18869/acadpub.ijrr.17.2.217
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: The aim of present study was to analyze the effectiveness of electron filters in the Telecobalt radiotherapy treatment by simulation technique. Materials and Methods: The BEAMnrc Monte Carlo code was used to simulate the electron filters of thickness of 0.5 gm/cm(2) below the trimmer bar for 35 x 35 cm(2) field size in Theratron Equinox-80 telecobalt unit. The electron filters were made of an aluminum, copper, nickel, tin, PMMA, and lead with single or composite materials. The radiation beams at treatment distance were analyzed by generating profiles for photon and electron along the X-axis of radiation field. Results: The electron energy fluence for unfiltered beam was 0.32% of the photon energy. The photon energy fluence intensity reduction due to filter was 3.7%. The filters with low atomic number have shown poor electron contamination removal efficiency. The tin, copper and nickel were found effective filters, removing nearly 38% of contaminant electron energy. The lead filter is equally effective as tin, however the high energy electrons emitted from filter due to "photo peaks" adds significant dose at 3.0 to 4.0 mm depth. Conclusion: The tin filter dominates over to other filters on the subject of surface dose reduction and depth of dose maximum (d(max)). It reduces the surface dose by 9.6% and 13.9 % of unfiltered beam for 15 x 15 and 20 x 20 cm(2) field sizes respectively.
引用
收藏
页码:217 / 227
页数:11
相关论文
共 50 条
  • [41] Monte Carlo simulation of electron transmission through masks in projection electron lithography
    Xiao Pei
    Zhang Zeng-Ming
    Sun Xia
    Ding Ze-Jun
    ACTA PHYSICA SINICA, 2006, 55 (11) : 5803 - 5809
  • [42] Application of variance reduction techniques in Monte Carlo simulation of clinical electron linear accelerator
    Zoubair, M.
    El Bardouni, T.
    El Gonnouni, L.
    Boulaich, Y.
    El Bakkari, B.
    El Younoussi, C.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2012, 661 (01) : 93 - 97
  • [43] Effectiveness of optimum stratified sampling and estimation in Monte Carlo production simulation
    Huang, SR
    IEEE TRANSACTIONS ON POWER SYSTEMS, 1997, 12 (02) : 566 - 572
  • [44] Determination of electron backscattering coefficient of beryllium by a high-precision Monte Carlo simulation
    Hussain, Abrar
    Yang, Lihao
    Mao, Shifeng
    Da, Bo
    Tokesi, Karoly
    Ding, Z. J.
    NUCLEAR MATERIALS AND ENERGY, 2021, 26
  • [45] EFFECTIVENESS OF MONTE CARLO SIMULATION AND ARIMA MODEL IN PREDICTING STOCK PRICES
    Arnaut-Berilo, Almira
    Zaimovic, Azra
    Turbo-Merdan, Nedzmija
    5TH INTERNATIONAL SCIENTIFIC CONFERENCE ECONOMY OF INTEGRATION (ICEI 2017): THE ROLE OF ECONOMIC THOUGHT IN MODERN ENVIRONMENT, 2017, : 946 - 963
  • [46] Monte Carlo Simulation of Photon Way in Clinical Laser Therapy
    Ionita, Iulian
    Voitcu, Gabriel
    MEDICAL LASER APPLICATIONS AND LASER-TISSUE INTERACTIONS V, 2011, 8092
  • [47] Performance optimization in 4D radiation treatment planning using Monte Carlo simulation on the cloud
    Chow, James C. L.
    JOURNAL OF COMPUTATIONAL METHODS IN SCIENCES AND ENGINEERING, 2016, 16 (01) : 147 - 156
  • [48] Study of electron transport properties for wurtzite GaN and ZnO with full band Monte Carlo simulation
    Guo, BZ
    Ravaioli, U
    ACTA PHYSICA SINICA, 2002, 51 (10) : 2344 - 2348
  • [50] Depth dependence of electron backscatter: An energy spectral and dosimetry study using Monte Carlo simulation
    Chow, James C. L.
    Owrangi, Amir M.
    MEDICAL PHYSICS, 2009, 36 (02) : 594 - 601