A mid-infrared sensor for the determination of perfluorocarbon-based compounds in aquatic systems for geosequestration purposes

被引:16
作者
Rauh, Florian [1 ,2 ]
Schwenk, Matthias [1 ,2 ]
Pejcic, Bobby [1 ]
Myers, Matthew [1 ]
Ho, Koon-Bay [3 ]
Stalker, Linda [1 ]
Mizaikoff, Boris [2 ]
机构
[1] CSIRO, Earth Sci & Resource Engn, Bentley, WA 6102, Australia
[2] Univ Ulm, Inst Analyt & Bioanalyt Chem, D-89081 Ulm, Germany
[3] Natl Measurement Inst, Kensington, WA 6151, Australia
关键词
Perfluorocarbon; Geosequestration; Groundwater monitoring; Mid-infrared spectroscopy; Attenuated total reflectance; Optical sensor; CHLORINATED HYDROCARBONS; CO2; INJECTION; WAVE-GUIDES; WATER; STORAGE; TRACER; SPECTRA; RESERVOIR; BOZEMAN; LEAKAGE;
D O I
10.1016/j.talanta.2014.07.025
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Perfluorocarbon (PFC) compounds have been used as chemical tracer molecules to understand the movement of supercritical carbon dioxide for geosequestration monitoring and verification purposes. A commonly used method for detecting PFCs involves the collection of a sample from either soil-gas or the atmosphere via carbon-based sorbents which are then analyzed in a laboratory. However, PFC analysis in aquatic environments is neglected and this is an issue that needs to be considered since the PFC is likely to undergo permeation through the overlying water formations. This paper presents for the first time an innovative analytical method for the trace level in situ detection of PFCs in water. It reports on the development of a sensor based on mid-infrared attenuated total reflection (MIR-ATR) spectroscopy for determining the concentration of perfluoromethylcyclohexane (PMCH) and perfluoro-1,3-dimethylcyclohexane (PDCH) in aquatic systems. The sensor comprises a zinc selenide waveguide with the surface modified by a thin polymer film. The sensitivity of this device was investigated as a function of polymer type, coating thickness, and solution flow rates. The limit of detection (LOD) was determined to be 23 ppb and 79 ppb for PMCH and PDCH, respectively when using a 5 mu m thick polyisobutylene (PIB) coated waveguide. This study has shown that the MIR-ATR sensor can be used to directly quantify PFC-based chemical tracer compounds in water over the 20-400 ppb concentration range. Crown Copyright (C) 2014 Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:527 / 535
页数:9
相关论文
共 39 条
  • [1] MEASUREMENTS OF GAS TRACER RETENTION UNDER SIMULATED RESERVOIR CONDITIONS
    DUGSTAD, O
    BJORNSTAD, T
    HUNDERE, IA
    [J]. JOURNAL OF PETROLEUM SCIENCE AND ENGINEERING, 1993, 10 (01) : 17 - 25
  • [2] Perfluorocarbon compounds
    Faithfull, NS
    Weers, JG
    [J]. VOX SANGUINIS, 1998, 74 : 243 - 248
  • [3] THE USE OF FTIR-ATR SPECTROSCOPY TO CHARACTERIZE PENETRANT DIFFUSION IN POLYMERS
    FIELDSON, GT
    BARBARI, TA
    [J]. POLYMER, 1993, 34 (06) : 1146 - 1153
  • [4] A comparison of polymeric materials as pre-concentrating media for use with ATR/FTIR sensing
    Flavin, K
    Hughes, H
    Dobbyn, V
    Kirwan, P
    Murphy, K
    Steiner, H
    Mizaikoff, B
    McLoughlin, P
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2006, 86 (06) : 401 - 415
  • [5] Griffiths P. R., 2006, Fourier Transform Infrared Spectrometry
  • [6] Safe storage and effective monitoring of CO2 in depleted gas fields
    Jenkins, Charles R.
    Cook, Peter J.
    Ennis-King, Jonathan
    Undershultz, James
    Boreham, Chris
    Dance, Tess
    de Caritat, Patrice
    Etheridge, David M.
    Freifeld, Barry M.
    Hortle, Allison
    Kirste, Dirk
    Paterson, Lincoln
    Pevzner, Roman
    Schacht, Ulrike
    Sharma, Sandeep
    Stalker, Linda
    Urosevic, Milovan
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2012, 109 (02) : E35 - E41
  • [7] Gas-water-rock interactions in Frio Formation following CO2 injection:: Implications for the storage of greenhouse gases in sedimentary basins
    Kharaka, Y. K.
    Cole, D. R.
    Hovorka, S. D.
    Gunter, W. D.
    Knauss, K. G.
    Freifeld, B. M.
    [J]. GEOLOGY, 2006, 34 (07) : 577 - 580
  • [8] Changes in the chemistry of shallow groundwater related to the 2008 injection of CO2 at the ZERT field site, Bozeman, Montana
    Kharaka, Yousif K.
    Thordsen, James J.
    Kakouros, Evangelos
    Ambats, Gil
    Herkelrath, William N.
    Beers, Sarah R.
    Birkholzer, Jens T.
    Apps, John A.
    Spycher, Nicholas F.
    Zheng, Liange
    Trautz, Robert C.
    Rauch, Henry W.
    Gullickson, Kadie S.
    [J]. ENVIRONMENTAL EARTH SCIENCES, 2010, 60 (02) : 273 - 284
  • [9] New frontiers for mid-infrared sensors: Towards deep sea monitoring with a submarine FT-IR sensor system
    Kraft, M
    Jakusch, M
    Karlowatz, M
    Katzir, A
    Mizaikoff, B
    [J]. APPLIED SPECTROSCOPY, 2003, 57 (06) : 591 - 599
  • [10] A mid-infrared sensor for monitoring of chlorinated hydrocarbons in the marine environment
    Kraft, M
    Mizaikoff, B
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2000, 78 (3-4) : 367 - 383