Analysis of Heating and Cooling Loads of Electrochromic Glazing in High-Rise Residential Buildings in South Korea

被引:29
作者
Oh, Myunghwan [1 ]
Tae, Sungho [2 ]
Hwang, Sangkun [3 ]
机构
[1] Hanyang Univ, Sustainable Bldg Res Ctr, 55 Hanyangdaehak Ro, Ansan 15588, Gyeonggi Do, South Korea
[2] Hanyang Univ, Sch Architecture & Architectural Engn, 55 Hanyangdaehak Ro, Ansan 15588, Gyeonggi Do, South Korea
[3] ALU ENC Co, Res Ctr Technol, 10 Baekjegobun Ro 9 Gil, Seoul 05562, South Korea
关键词
electrochromic glazing; optical properties; heating and cooling loads; high-rise residential building; curtain wall; EnergyPlus; ENERGY PERFORMANCE; VISUAL COMFORT; DAYLIGHTING PERFORMANCE; WINDOW GLAZINGS; SAVINGS;
D O I
10.3390/su10041121
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This study compares the impact of the recently developed electrochromic glazing technology on load reduction by comparing it with the double-glazing and shading devices that are sold commercially for high-rise residential buildings in Korea. These buildings are similar to large office buildings in terms of their high window-to-wall ratio. The energy consumption of such buildings was simulated using an analytical model of a high-rise residential building. The patterns between the heating and cooling loads were found to be similar to that of office buildings, in that the cooling load was considerably higher than the heating load. This study hypothesizes that the load reduction performance of electrochromic glazing with variable solar control and high solar radiation rejection is superior to that of existing double-glazing products and shading devices. This hypothesis was tested by analyzing the cooling and heating loads of buildings with different types of double glazings. Bleached electrochromic glazing exhibited lower transmittance than colored glass double glazing, low-e double glazing, and double glazing with a shading device, and is thus not effective in reducing heating load. Colored electrochromic glazing provided higher solar radiation rejection than colored glass double glazing and low-e double glazing, and thus is effective in reducing cooling load.
引用
收藏
页数:25
相关论文
共 31 条
[1]   Thermal comfort and visual comfort in an office building equipped with smart electrochromic glazing: an experimental study [J].
Ajaji, Youness ;
Andre, Philippe .
6TH INTERNATIONAL BUILDING PHYSICS CONFERENCE (IBPC 2015), 2015, 78 :2464-2469
[2]  
American Society of Heating Refrigerating and Air-Conditioning Engineers Inc, 2009, ASHRAE FUNDAMENTALS
[3]  
[Anonymous], 2003, ISO 15099
[4]  
Arasteh D.K., 1989, ASHRAE Transactions, V95
[5]  
Arasteh D. K., 2009, DRAFT MODELING WINDO
[6]   Perovskite photovoltachromic cells for building integration [J].
Cannavale, Alessandro ;
Eperon, Giles E. ;
Cossari, Pierluigi ;
Abate, Antonio ;
Snaith, Henry J. ;
Gigli, Giuseppe .
ENERGY & ENVIRONMENTAL SCIENCE, 2015, 8 (05) :1578-1584
[7]  
Chantrasrisalai C., 2004, P SIMBUILD 2004 BOUL
[8]   Regional performance targets for transparent near-infrared switching electrochromic window glazings [J].
DeForest, Nicholas ;
Shehabi, Arman ;
Garcia, Guillermo ;
Greenblatt, Jeffery ;
Masanet, Eric ;
Lee, Eleanor S. ;
Selkowitz, Stephen ;
Milliron, Delia J. .
BUILDING AND ENVIRONMENT, 2013, 61 :160-168
[9]  
Elizabeth P., 2017, INT J SUSTAIN BUILD, V8, P201
[10]  
EnergyPlus, ENC REF ENERGYPLUS I