摘要
Objective: Although fine-needle aspiration biopsy (FNAB) of thyroid nodules is a reliable and simple method, the diagnostic value may be limited by inadequate and false-negative results. In this prospective study, we compared palpation-guided FNAB (PGFNAB) with ultrasound-guided FNAB (UGFNAB) to establish the rates of inadequate material and cost-effectiveness. Design: A total of 285 thyroid nodules in 215 patients were included in the study. Palpable nodules with the greatest diameter between 1 and 2.5 cm were included in the study. PGFNAB and UGFNAB techniques were applied to the same nodule by the same operator. Cytologic evaluations were performed by the same cytologist in a blinded fashion. To provide cost analysis, the prices obtained from different hospitals were evaluated. Main outcome: The rates of inadequate material for PGFNAB and UGFNAB were significantly different as 32.3% and 21.4%, respectively (p = 0.004). There was significantly higher inadequate material rate in PGFNAB group for small-sized nodules (greatest nodule diameter between 10 and 15 mm) (p = 0.009), despite inadequate material rate was not significant for both procedures for larger sized nodules. False-negative results were 15.8% for PGFNAB and 5.6% for UGFNAB. Regarding cost analysis, the difference between the two methods was $20 on average for each patient. Conclusions: We consider UGFNAB to be superior to PGFNAB for obtaining adequate material especially for small-sized nodules, as well as providing more accurate cytologic evaluation. Indeed, the difference between the costs of two procedures might be acceptable.
引用
收藏
页码:555 / 561
页数:7
相关论文
共 50 条
  • [21] Ultrasound-guided fine-needle aspiration versus fine-needle capillary sampling biopsy of thyroid nodules - Does technique matter?
    Tublin, Mitchell E.
    Martin, Joseph A.
    Rollin, Lori J.
    Pealer, Karen
    Kurs-Lasky, Marcia
    Ohori, N. Paul
    JOURNAL OF ULTRASOUND IN MEDICINE, 2007, 26 (12) : 1697 - 1701
  • [22] Comparison of palpation-versus ultrasound-guided fine-needle aspiration biopsies in the evaluation of thyroid nodules
    Can A.S.
    Peker K.
    BMC Research Notes, 1 (1)
  • [23] Ultrasound-guided fine-needle aspiration biopsy in skin lesions
    Fernando, Alfageme
    Laura, Najera
    Pablo, Fonda
    Gaston, Roustan
    SKIN RESEARCH AND TECHNOLOGY, 2019, 25 (03) : 399 - 401
  • [24] Ultrasound-guided fine-needle aspiration biopsy of lung cancers
    Hsu, WH
    Chiang, CD
    Hsu, JY
    Kwan, PC
    Chen, CL
    Chen, CY
    JOURNAL OF CLINICAL ULTRASOUND, 1996, 24 (05) : 225 - 233
  • [25] US-guided fine-needle aspiration biopsy of thyroid nodules
    Court-Payen, M
    Nygaard, B
    Horn, T
    Jacobsen, GK
    Brændstrup, O
    Narvestad, E
    Pedersen, LM
    Hancke, S
    Holm, HH
    ACTA RADIOLOGICA, 2002, 43 (02) : 131 - 140
  • [26] ULTRASOUND-GUIDED FINE-NEEDLE ASPIRATION BIOPSY OF NECK NODES
    DEJONG, RJB
    RONGEN, RJ
    VERWOERD, CDA
    VANOVERHAGEN, H
    LAMERIS, JS
    KNEGT, P
    ARCHIVES OF OTOLARYNGOLOGY-HEAD & NECK SURGERY, 1991, 117 (04) : 402 - 404
  • [27] The Case for Pathologist Ultrasound-guided Fine-Needle Aspiration Biopsy
    Abele, John S.
    CANCER CYTOPATHOLOGY, 2008, 114 (06) : 463 - 468
  • [28] Ultrasound-Guided Fine-Needle Aspiration Biopsy of Thyroid Nodules: Comparison in Efficacy According to Nodule Size
    Kim, Dong Wook
    Lee, Eun Joo
    Kim, Sang Hyo
    Kim, Tae Hyun
    Lee, Sang Hyub
    Kim, Dae Hwan
    Rho, Myung Ho
    THYROID, 2009, 19 (01) : 27 - 31
  • [29] The results of ultrasound-guided fine-needle aspiration biopsy for evaluation of nodular thyroid disease
    Mittendorf, EA
    Tamarkin, SW
    McHenry, CR
    SURGERY, 2002, 132 (04) : 648 - 653
  • [30] Comparison of Cytopathologist-Performed Ultrasound-Guided Fine-Needle Aspiration With Cytopathologist-Performed Palpation-Guided Fine-Needle Aspiration A Single Institutional Experience
    Conrad, Rachel
    Yang, Sung-Eun
    Chang, Shelley
    Bhasin, Meenakshi
    Sullivan, Peggy S.
    Moatamed, Neda A.
    Lu, David Y.
    ARCHIVES OF PATHOLOGY & LABORATORY MEDICINE, 2018, 142 (10) : 1260 - 1267