Tracheal intubation using the ILMA, C-Trach™ or McCoy laryngoscope in patients with simulated cervical spine injury

被引:30
作者
Bilgin, H. [1 ]
Bozkurt, M. [1 ]
机构
[1] Uludag Univ, Fac Med, Dept Anaesthesiol & Intens Care, TR-16059 Bursa, Turkey
关键词
D O I
10.1111/j.1365-2044.2006.04706.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
A study of 90 patients was undertaken to compare intubation success rates of using either ILMA, C-Trach(TM) or McCoy laryngoscope in patients with simulated cervical spine injury. Insertion and intubation success rates, time taken to achieve intubation, airway complications and haemodynamic parameters were recorded. Insertion of ILMA and C-Trach(TM) was successful at the first attempt in all patients. Intubation success rates were higher in the C-Trach (100%) and McCoy (100%) groups than in the ILMA (87%) group. Total intubation time was significantly longer in the ILMA (63 s, SD 36.5) group than in the C-Trach (41 s, SD 15.8) and McCoy (30 s, SD 7.4) groups (p < 0.05, p < 0.05, respectively). There were no significant differences in haemodynamic parameters among the groups at any time.
引用
收藏
页码:685 / 691
页数:7
相关论文
共 30 条
[1]   The intubating laryngeal mask - Clinical appraisal of ventilation and blind tracheal intubation in 110 patients [J].
Agro, F ;
Brimacombe, J ;
Carassiti, M ;
Marchionni, L ;
Morelli, A ;
Cataldo, R .
ANAESTHESIA, 1998, 53 (11) :1084-1090
[2]   Placement of the intubating laryngeal mask is easier than the laryngeal mask during manual in-line neck stabilization [J].
Asai, T ;
Wagle, AU ;
Stacey, M .
BRITISH JOURNAL OF ANAESTHESIA, 1999, 82 (05) :712-714
[3]   Ease of tracheal intubation through the intubating laryngeal mask during manual in-line head and neck stabilisation [J].
Asai, T ;
Murao, K ;
Tsutsumi, T ;
Shingu, K .
ANAESTHESIA, 2000, 55 (01) :82-85
[4]   Tracheal intubation through the intubating laryngeal mask in patients with unstable necks [J].
Asai, T ;
Shingu, K .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2001, 45 (07) :818-822
[5]   The intubating laryngeal mask - Results of a multicentre trial with experience of 500 cases [J].
Baskett, PJF ;
Parr, MJA ;
Nolan, JP .
ANAESTHESIA, 1998, 53 (12) :1174-1179
[6]   Awake intubation through the CTrach in the presence of an unstable cervical spine [J].
Bilgin, H ;
Yylmaz, C .
ANAESTHESIA, 2006, 61 (05) :513-514
[7]  
BRAIN AIJ, 1997, LMA FASTRACH INSTRUC
[8]   An unexpected complication of the intubating laryngeal mask [J].
Branthwaite, MA .
ANAESTHESIA, 1999, 54 (02) :166-167
[9]   Intubating laryngeal mask airway [J].
Caponas, G .
ANAESTHESIA AND INTENSIVE CARE, 2002, 30 (05) :551-569
[10]   The cardiovascular response to insertion of the intubating laryngeal mask airway [J].
Choyce, A ;
Avidan, MS ;
Harvey, A ;
Patel, C ;
Timberlake, C ;
Sarang, K ;
Tilbrook, L .
ANAESTHESIA, 2002, 57 (04) :330-333