Determination of capsaicinoids by magnetic solid phase extraction coupled with UPLC-MS/MS for screening of gutter oil

被引:21
|
作者
Lu, Qing [1 ]
Guo, Hao [2 ]
Li, Dezeng [1 ]
Zhao, Qingbiao [3 ]
机构
[1] East China Normal Univ, Sch Chem & Mol Engn, Shanghai 200241, Peoples R China
[2] Chonqing Inst Forens Sci, Chongqing 400021, Peoples R China
[3] East China Normal Univ, Dept Elect Sci, Key Lab Polar Mat & Devices MOE, Shanghai 200241, Peoples R China
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2020年 / 1158卷
基金
中国国家自然科学基金;
关键词
Capsaicinoid; Gutter oil; Magnetic solid phase extraction; Graphene oxide; Ultra-high performance liquid chromatography; CAPSICUM; PEPPERS; DIHYDROCAPSAICIN;
D O I
10.1016/j.jchromb.2020.122344
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Capsaicinoids, including capsaicin, dihydrocapsaicin and N-vanillylnonanamide have been identified as characteristic markers for gutter oil. In this study, the nanocomposite of graphene oxide-Fe3O4 (GO-Fe3O4) was synthesized by a co-precipitation method, and applied to magnetic solid phase extraction (MSPE) process. The capsaicin, dihydrocapsaicin and N-vanillylnonanamide extracted in gutter oil were analyzed by ultrahigh performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). Under the optimized pretreatment conditions, the limit of detection (LOD) and limit of quantification (LOQ) are 0.15 and 0.4 mu g L-1, respectively. The linear range is 0.4-200 mu g L-1, and the correlation coefficients (R-2) are over 0.996 for all three compounds. The recoveries range from 81.2% to 103.3% for soybean oil and 71.2% to 84.3% for rapeseed oil. The values of matrix effect range in 87.6%-105.5% and 83.4%-110.6% and the intra-day RSDs range from 2.8%-4.6% to 4.8%-6.1% for soybean oil and rapeseed oil, respectively. The adsorbent can be reused for multiple times with no appreciable loss of adsorption capability. The present methodology has high potential for screening of gutter oil in food samples, thus having importance for food safety monitoring.
引用
收藏
页数:5
相关论文
共 50 条
  • [41] Analysis of aristolochic acid I in mouse serum and tissues by using magnetic solid-phase extraction and UHPLC-MS/MS
    Guo, Wenjing
    Shi, Zhangsheng
    Zhang, Jing
    Zeng, Ting
    He, Yu
    Cai, Zongwei
    TALANTA, 2021, 235
  • [42] Magnetic solid-phase extraction based on carbon nanotubes for the determination of polyether antibiotic and s-triazine drug residues in animal food with LC-MS/MS
    Liu, Xiaoxing
    Xie, Shuyu
    Ni, Tengteng
    Chen, Dongmei
    Wang, Xu
    Pan, Yuanhu
    Wang, Yulian
    Huang, Lingli
    Cheng, Guyue
    Qu, Wei
    Liu, Zhenli
    Tao, Yanfei
    Yuan, Zonghui
    JOURNAL OF SEPARATION SCIENCE, 2017, 40 (11) : 2416 - 2430
  • [43] Determination of four cannabinoids in wastewater based on a hyperbranched mixed-mode anion exchange magnetic solid-phase extraction adsorbent combined with UHPLC-MS/MS
    Zhou, Jing
    Ning, Hongyu
    Wang, Haixing
    Zhao, Sen
    Xu, Yu
    Fan, Yilei
    Huang, Zhongping
    Gao, Jianhong
    MICROCHEMICAL JOURNAL, 2025, 210
  • [44] Magnetic solid phase extraction for determination of drugs in biological matrices
    Vasconcelos, Ingrid
    Fernandes, Christian
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2017, 89 : 41 - 52
  • [45] Magnetic solid-phase extraction based on polydopamine-coated magnetic nanoparticles for rapid and sensitive analysis of eleven illicit drugs and metabolites in wastewater with the aid of UHPLC-MS/MS
    Yuan, Shuai
    Xiang, Yangjiayi
    Chen, Lizhu
    Xiang, Ping
    Li, Yan
    JOURNAL OF CHROMATOGRAPHY A, 2024, 1718
  • [46] Integration of stable isotope labeling derivatization and magnetic dispersive solid phase extraction for measurement of neurosteroids by in vivo microdialysis and UHPLC-MS/MS
    Xu, Yanqiu
    Sun, Luping
    Wang, Xin
    Zhu, Shuyun
    You, Jinmao
    Zhao, Xian-En
    Bai, Yu
    Liu, Huwei
    TALANTA, 2019, 199 : 97 - 106
  • [47] Magnetic nanocomposite as sorbent for magnetic solid phase extraction coupled with high performance liquid chromatography for determination of polycyclic aromatic hydrocarbons
    Yang, Xiupei
    Yin, Yanru
    Zong, Yingying
    Wan, Ting
    Liao, Xiangjun
    MICROCHEMICAL JOURNAL, 2019, 145 : 26 - 34
  • [48] Fractional factorial design-based optimisation and application of an extraction and UPLC-MS/MS detection method for the quantification of phytosterols in food, feed and beverages low in phytosterols
    Decloedt, Anneleen I.
    Van Landschoot, Anita
    Vanhaecke, Lynn
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2016, 408 (27) : 7731 - 7744
  • [49] Improved enrichment and analysis of heterocyclic aromatic amines in thermally processed foods by magnetic solid phase extraction combined with HPLC-MS/MS
    Feng, Yanmei
    Xu, Ying
    Li, Wenrui
    Chen, Shasha
    Su, Zhuoqun
    Xi, Lingyi
    Li, Guoliang
    FOOD CONTROL, 2022, 137
  • [50] Computer-aided design of magnetic dummy molecularly imprinted polymers for solid-phase extraction of ten phthalates from food prior to their determination by GC-MS/MS
    Lu, Chunxia
    Tang, Zonggui
    Gao, XiaoXu
    Ma, Xiaomei
    Liu, Changbin
    MICROCHIMICA ACTA, 2018, 185 (08)