Optimization of a measurement facility for radioactive waste free release by Monte Carlo simulation

被引:5
作者
Solc, Jaroslav [1 ]
Kovar, Petr [1 ]
Suran, Jiri [1 ]
Peyres, Virginia [2 ]
Garcia-Torano, Eduardo [2 ]
机构
[1] Czech Metrol Inst, Inspectorate Ionizing Radiat, Prague 10200 10, Czech Republic
[2] CIEMAT, Lab Metrol Radiac Ionizantes, E-28040 Madrid, Spain
关键词
Free release measurement; Low activity measurement; Monte Carlo simulation; MCNPX; PENELOPE;
D O I
10.1016/j.apradiso.2013.11.005
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
A novel free release measurement facility (FRMF) was developed within the joint research project "Metrology for Radioactive Waste Management" of the European Metrology Research Programme. Before and during FRMF design and construction, Monte Carlo calculations with MCNPX and PENELOPE codes were used to optimize the thickness of the shielding, the dimensions of the container, and the shape of detector collimators. Validation of the numerical models of the FRMF detectors and the results of the optimization are discussed in the paper. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:348 / 352
页数:5
相关论文
共 5 条
  • [1] [Anonymous], 2011, MCNPX 2 7 E EXTENSIO
  • [2] Salvat F., 2006, PENELOPE-2006: A Code System for Monte Carlo Simulation of Electron and Photon Transport
  • [3] Sato T., 2006, EXPACS EXCEL BASED P
  • [4] Solc J., 2012, MCNPX SIMULATION INF
  • [5] Suran J., 2013, 1 JRP ENV09 WORKSH P