CON4EI: Bovine Corneal Opacity and Permeability (BCOP) test for hazard identification and labelling of eye irritating chemicals (Reprinted from Toxicology in Vitro, vol 44C, pg 122-133)

被引:10
作者
Verstraelen, Sandra [1 ]
Maglennon, Gareth [2 ]
Hollanders, Karen [1 ]
Boonen, Francis [1 ]
Adriaens, Els [3 ]
Alepee, Nathalie [4 ]
Drzewiecka, Agnieszka [5 ]
Gruszka, Katarzyna [5 ]
Kandarova, Helena [6 ]
Willoughby, Jamin A., Sr. [7 ]
Guest, Robert [2 ]
Schofield, Jane [2 ]
Van Rompay, An R. [1 ]
机构
[1] VITO NV Flemish Inst Technol Res, Boeretang 200, B-2400 Mol, Belgium
[2] Envigo, Huntingdon, Cambs, England
[3] Adriaens Consulting BVBA, Aalter, Belgium
[4] Oreal Res & Innovat, Aulnay Sous Bois, France
[5] Inst Ind Organ Chem, Branch Pszczyna, Pszczyna, Poland
[6] MatTek Vitro Life Sci Labs, Bratislava, Slovakia
[7] Cyprotex US LLC, Northville, MI USA
关键词
CON4EI; Ocular irritation; Bovine Comeal Opacity and Permeability (BCOP); OP-KIT; Laser Light-Based Opacitometer (LLBO); Histopathology; OECD Test Guideline 437; ASSAY; CLASSIFICATION; IMPROVEMENT;
D O I
10.1016/j.tiv.2018.03.005
中图分类号
R99 [毒物学(毒理学)];
学科分类号
100405 ;
摘要
Assessment of ocular irritation potential is an international regulatory requirement in the safety evaluation of industrial and consumer products. None in vitro ocular irritation assays are capable of fully categorizing chemicals as stand-alone. Therefore, the CEFIC-LRI-AIMT6-VITO CON4EI consortium assessed the reliability of eight in vitro test methods and computational models as well as established a tiered-testing strategy. One of the selected assays was Bovine Corneal Opacity and Permeability (BCOP). In this project, the same corneas were used for measurement of opacity using the OP-KIT, the Laser Light-Based Opacitometer (LLBO) and for histopathological analysis. The results show that the accuracy of the BCOP OP-KIT in identifying Cat 1 chemicals was 73.8% while the accuracy was 86.3% for No Cat chemicals. BCOP OP-KIT false negative results were often related to an in vivo classification driven by conjunctival effects only. For the BCOP LLBO, the accuracy in identifying Cat 1 chemicals was 74.4% versus 88.8% for No Cat chemicals. The BCOP LLBO seems very promising for the identification of No Cat liquids but less so for the identification of solids. Histopathology as an additional endpoint to the BCOP test method does not reduce the false negative rate substantially for in vivo Cat 1 chemicals.
引用
收藏
页码:53 / 64
页数:12
相关论文
共 21 条
[11]  
OECD, 2011, OECD SER TEST ASS NO, V160
[12]  
OECD, 2017, DRAFT GUID DOC INT A
[13]  
Pournelle G. H., 1953, Journal of Mammalogy, V34, P133, DOI 10.1890/0012-9658(2002)083[1421:SDEOLC]2.0.CO
[14]  
2
[15]   The Bovine Corneal Opacity and Permeability Test in Routine Ocular Irritation Testing and Its Improvement Within the Limits of OECD Test Guideline 437 [J].
Schrage, Arnhild ;
Kolle, Susanne N. ;
Moreno, Maria C. Rey ;
Norman, Kimberly ;
Raabe, Hans ;
Curren, Rodger ;
van Ravenzwaay, Bennard ;
Landsiedel, Robert .
ATLA-ALTERNATIVES TO LABORATORY ANIMALS, 2011, 39 (01) :37-53
[16]   A proposed eye irritation testing strategy to reduce and replace in vivo studies using Bottom-Up and Top-Down approaches [J].
Scott, Laurie ;
Eskes, Chantra ;
Hoffmann, Sebastian ;
Adriaens, Els ;
Alepee, Nathalie ;
Bufo, Monica ;
Clothier, Richard ;
Facchini, Davide ;
Faller, Claudine ;
Guest, Robert ;
Harbell, John ;
Hartung, Thomas ;
Kamp, Hennicke ;
Le Varlet, Beatrice ;
Meloni, Marisa ;
McNamee, Pauline ;
Osborne, Rosemarie ;
Pape, Wolfgang ;
Pfannenbecker, Uwe ;
Prinsen, Menk ;
Seaman, Christopher ;
Spielmann, Horst ;
Stokes, William ;
Trouba, Kevin ;
Van den Berghe, Christine ;
Van Goethem, Freddy ;
Vassallo, Marco ;
Vinardell, Pilar ;
Zuang, Valerie .
TOXICOLOGY IN VITRO, 2010, 24 (01) :1-9
[17]  
United Nations. Economic Commission for Europe. Secretariat Globally harmonized system of classification and labelling of chemicals (GHS), 2015, COP LAW UN
[18]   Development of a new opacitometer for the bovine corneal opacity and permeability (BCOP) assay [J].
Van Goethem, Freddy ;
Hansen, Erik ;
Sysmans, Marc ;
De Smedt, Ann ;
Vanparys, Philippe ;
Van Gompel, Jacky .
TOXICOLOGY IN VITRO, 2010, 24 (06) :1854-1861
[19]   EVALUATION OF THE BOVINE CORNEAL OPACITY PERMEABILITY ASSAY AS AN IN-VITRO ALTERNATIVE TO THE DRAIZE EYE IRRITATION TEST [J].
VANPARYS, P ;
DEKNUDT, G ;
SYSMANS, M ;
TEUNS, G ;
COUSSEMENT, W ;
VANCAUTEREN, H .
TOXICOLOGY IN VITRO, 1993, 7 (04) :471-476
[20]  
VERSTRAELEN S, TOXICOLOGY VITRO C, V44, P122