Cone-beam computed tomography for trauma

被引:3
作者
Gupta, Saurabh [1 ]
Martinson, James R. [2 ]
Ricaurte, Daniel [2 ]
Scalea, Thomas M. [2 ]
Morrison, Jonathan J. [2 ]
机构
[1] Univ Maryland, St Agnes Hosp, Baltimore, MD 21201 USA
[2] Univ Maryland, Ctr Shock Trauma, Baltimore, MD 21201 USA
关键词
Cone-beam CT; CBCT; hybrid operating room; IMAGE QUALITY; CT; ANGIOGRAPHY; DYNACT; HEAD; NECK;
D O I
10.1097/TA.0000000000002748
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Radiographic imaging is critical in helping guide treatment of critically injured patients. Cone-beam computed tomography is an axial imaging technique available from fixed imaging systems found in hybrid operating rooms. It can be used to provide focused studies of specific anatomical regions, where patients cannot undergo conventional multidetector computed tomography. This includes non-contrast-enhanced evaluation of the intracranial contents and vascular imaging throughout the body. There are a number of advantages and disadvantages to cone-beam computed tomography, but these are not widely discussed within the trauma literature. This narrative review article presents the initial practical experience of this novel imaging modality.
引用
收藏
页码:E34 / E40
页数:7
相关论文
共 41 条
[1]  
Associacao Portuguesa de Infeccao Hospitalar: APIH, HYBR OR ADV IM EN IM
[2]   Incidental Findings on Cone Beam Computed Tomography Studies outside of the Maxillofacial Skeleton [J].
Barghan, Sevin ;
Arashlow, Mehrnaz Tahmasbi ;
Nair, Madhu K. .
INTERNATIONAL JOURNAL OF DENTISTRY, 2016, 2016
[3]  
Boone John M, 2008, J Am Coll Radiol, V5, P132, DOI 10.1016/j.jacr.2007.07.008
[4]  
Centers for Disease Control and Prevention, TRAUM BRAIN INJ US I
[5]   Statistical reconstruction for cone-beam CT with a post-artifact-correction noise model: application to high-quality head imaging [J].
Dang, H. ;
Stayman, J. W. ;
Sisniega, A. ;
Xu, J. ;
Zbijewski, W. ;
Wang, X. ;
Foos, D. H. ;
Aygun, N. ;
Koliatsos, V. E. ;
Siewerdsen, J. H. .
PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (16) :6153-6175
[6]  
DenOtter TD., 2019, Tech. Rep.
[7]   Intraoperative C-arm cone-beam computed tomography in fenestrated/branched aortic endo grafting [J].
Dijkstra, Martijn L. ;
Eagleton, Matthew J. ;
Greenberg, Roy K. ;
Mastracci, Tara ;
Hernandez, Adrian .
JOURNAL OF VASCULAR SURGERY, 2011, 53 (03) :583-590
[8]   Dose and image quality for a cone-beam C-arm CT system [J].
Fahrig, Rebecca ;
Dixon, Robert ;
Payne, Thomas ;
Morin, Richard L. ;
Ganguly, Arundhuti ;
Strobel, Norbert .
MEDICAL PHYSICS, 2006, 33 (12) :4541-4550
[9]  
Flohr T, 2004, MED RAD DIA IMG, P3
[10]  