Feedforward Current References Control for DFIG-Based Wind Turbine to Improve Transient Control Performance During Grid Faults

被引:90
|
作者
Zhu, Donghai [1 ]
Zou, Xudong [1 ]
Zhou, Shiying [1 ]
Dong, Wen [1 ]
Kang, Yong [1 ]
Hu, Jiabing [1 ]
机构
[1] Huazhong Univ Sci & Technol, Sch Elect & Elect Engn, State Key Lab Adv Electromagnet Engn & Technol, Wuhan 430074, Hubei, Peoples R China
基金
国家重点研发计划;
关键词
AC current references; doubly fed induction generator (DFIG); feedforward current references control (FCRC); low-voltage ride through (LVRT); references tracking; FED INDUCTION GENERATOR; RIDE-THROUGH; SYSTEMS; DYNAMICS; TRACKING; FRAME;
D O I
10.1109/TEC.2017.2779864
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
For doubly fed induction generator (DFIG) based wind turbines, when severe grid faults occur, it is necessary to inject transient and negative-sequence components into the rotor current reference to achieve controllable low-voltage ride through (LVRT) capability. However, the classical proportional-integral (PI) controller cannot provide precise control of the transient and negative-sequence rotor current, because such current references in synchronous reference frame (SRF) are ac components at grid frequency and double grid frequency, respectively. To solve this problem, this paper proposes a feedforward current references control (FCRC) method for rotor-side converter to improve the system transient control performance. Under the proposed method, the additional feedforward of rotor current references is introduced into the current loop to improve its tracking capability of the aforementioned ac current references, thereby achieving the transient control targets precisely. Moreover, the proposed method will not affect the stability of the original current loop. Furthermore, the method has strong robustness against DFIG parameters deviation and grid frequency variations. In addition, the method is highly simple to implement. Finally, the validity of the proposed FCRC method is demonstrated by simulation and experiment.
引用
收藏
页码:670 / 681
页数:12
相关论文
共 50 条
  • [1] Transient Analysis and Control Solutions for DFIG-based Wind Turbine Generators to Improve FRT Performance under Asymmetrical Faults
    Chang, Yuanzhu
    Zhao, Mingxuan
    Kocar, Ilhan
    Karaagac, Ulas
    2022 IEEE 9TH INTERNATIONAL CONFERENCE ON POWER ELECTRONICS SYSTEMS AND APPLICATIONS, PESA, 2022,
  • [2] Synchronization Instability Mechanism and Damping Enhancement Control for DFIG-Based Wind Turbine During Grid Faults
    Yang, Yihang
    Zhu, Donghai
    Zhou, Dangsheng
    Zou, Xudong
    Hu, Jiabing
    Kang, Yong
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2023, 38 (10) : 12104 - 12115
  • [3] Feedforward Current Reference Control for DFIG During Grid Faults
    Zhu, Donghai
    Zou, Xudong
    Huang, Qingjun
    Zhou, Shiying
    Gao, Xiaolu
    Kang, Yong
    IECON 2015 - 41ST ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2015, : 1579 - 1584
  • [4] Feedforward current reference control for DFIG during grid faults
    20162402482639
    (1) State Key Laboratory of Advanced Electromagnetic Engineering and Technology, Huazhong University of Science and Technology, Wuhan, China, 1600, IEEE Industrial Electonics Society (IES) (Institute of Electrical and Electronics Engineers Inc., United States):
  • [5] Modeling and Control of a DFIG-Based Wind Turbine During a Grid Voltage Drop
    Lajimi, A. Babaie
    Gholamian, S. Asghar
    Shahabi, M.
    ENGINEERING TECHNOLOGY & APPLIED SCIENCE RESEARCH, 2011, 1 (05) : 121 - 125
  • [6] Transient Stability Analysis and Enhancement of DFIG-Based Wind Turbine With Demagnetization Control During Grid Fault
    Ma, Yumei
    Zhu, Donghai
    Zhu, Haipeng
    Hu, Jiabing
    Zou, Xudong
    Kang, Yong
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2025, 61 (01) : 1031 - 1042
  • [7] Voltage Control of DFIG-based Wind Turbine Generator in Rural Grid
    Sakurai, Satoshi
    Sakamoto, Orie
    2023 12TH INTERNATIONAL CONFERENCE ON RENEWABLE ENERGY RESEARCH AND APPLICATIONS, ICRERA, 2023, : 203 - 207
  • [8] Inductance-Simulating Control for DFIG-Based Wind Turbine to Ride-through Grid Faults
    Zhu, Donghai
    Zou, Xudong
    Kang, Yong
    Deng, Lu
    Huang, Qingjun
    APEC 2016 31ST ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION, 2016, : 3521 - 3525
  • [9] Inductance-Emulating Control for DFIG-Based Wind Turbine to Ride-Through Grid Faults
    Zhu, Donghai
    Zou, Xudong
    Deng, Lu
    Huang, Qingjun
    Zhou, Shiying
    Kang, Yong
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2017, 32 (11) : 8514 - 8525
  • [10] Optimized Design of Demagnetization Control for DFIG-Based Wind Turbines to Enhance Transient Stability During Weak Grid Faults
    Ma, Yumei
    Zhu, Donghai
    Hu, Jiabing
    Liu, Ruikuo
    Zou, Xudong
    Kang, Yong
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2025, 40 (01) : 76 - 81