Charge sharing in double-sided 3D Medipix2 detectors

被引:8
作者
Pennicard, D. [1 ]
Fleta, C. [1 ]
Bates, R. [1 ]
O'Shea, V. [1 ]
Parkes, C. [1 ]
Pellegrini, G. [3 ]
Lozano, M. [3 ]
Marchal, J. [2 ]
Tartoni, N. [2 ]
机构
[1] Univ Glasgow, Dept Phys & Astron, Glasgow G12 8QQ, Lanark, Scotland
[2] Diamond Light Source Ltd, Oxford OX11 0DE, England
[3] CSIC, CNM IMB, Barcelona 08193, Spain
关键词
3D detectors; Charge sharing; X-ray detectors; Synchrotron; Medipix; PIXEL; PARTICLES; DEVICE;
D O I
10.1016/j.nima.2009.01.095
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
3D detectors are photodiode detectors with n- and p-type electrode columns passing through a silicon substrate. This structure gives a much smaller spacing between the electrodes than in a standard photodiode, greatly reducing the detector's operating voltage and collection time. The device structure also reduces charge sharing between adjacent pixels. This improves the image quality, making these detectors potentially useful for applications such as X-ray diffraction experiments in synchrotrons. A set of silicon detectors with a simplified "double-sided" 3D structure have been fabricated. After being bump-bonded to Medipix2 single-photon-counting readout chips, they have been tested using X-rays and alpha particles. The test results show that the 3D detectors have substantially lower charge sharing than a planar detector of the same thickness. (c) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:412 / 415
页数:4
相关论文
共 9 条
  • [1] Study of the charge sharing in a silicon pixel detector by means of α-particles interacting with a Medipix2 device
    Campbell, M.
    Heijne, E.
    Holy, T.
    Idarraga, J.
    Jakubek, J.
    Lebel, C.
    Leroy, C.
    Llopart, X.
    Pospisil, S.
    Tlustos, L.
    Vykydal, Z.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2008, 591 (01) : 38 - 41
  • [2] Performance limits of a single photon counting pixel system
    Chmeissani, M
    Mikulec, B
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 460 (01) : 81 - 90
  • [3] Advances in silicon detectors for particle tracking in extreme radiation environments
    Da Via, C
    Anelli, G
    Hasi, J
    Jarron, P
    Kenney, C
    Kok, A
    Parker, S
    Perozziello, E
    Watts, SJ
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 509 (1-3) : 86 - 91
  • [4] Observation of beta and X rays with 3-D-architecture silicon microstrip sensors
    Kenney, CJ
    Parker, SI
    Krieger, B
    Ludewigt, B
    Dubbs, TP
    Sadrozinski, H
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (02) : 189 - 193
  • [5] Medipix2:: a 64-k pixel readout chip with 55 μm square elements working in single photon counting mode
    Llopart, X
    Campbell, M
    Dinapoli, R
    Segundo, DS
    Pemigotti, E
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (05) : 2279 - 2283
  • [6] 3D - A proposed new architecture for solid-state radiation detectors
    Parker, SI
    Kenney, CJ
    Segal, J
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 395 (03) : 328 - 343
  • [7] First double-sided 3-D detectors fabricated at CNM-IMB
    Pellegrini, G.
    Lozano, M.
    Ullan, M.
    Bates, R.
    Fleta, C.
    Pennicard, D.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2008, 592 (1-2) : 38 - 43
  • [8] PENNICARD D, J SYNCHROTRON UNPUB
  • [9] USB interface for Medipix2 pixel device enabling energy and position-sensitive detection of heavy charged particles
    Vykydal, Z
    Jakubek, J
    Pospisil, S
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 563 (01) : 112 - 115