Radiation protection for an intraoperative X-ray source compared to C-arm fluoroscopy

被引:14
|
作者
Schneider, Frank [1 ]
Clausen, Sven [1 ]
Jahnke, Anika [1 ]
Steil, Volker [1 ]
Bludau, Frederic [2 ]
Suetterlin, Marc [3 ]
Obertacke, Udo [2 ]
Wenz, Frederik [1 ]
机构
[1] Heidelberg Univ, Univ Med Ctr Mannheim, Dept Radiat Oncol, D-68167 Mannheim, Germany
[2] Heidelberg Univ, Univ Med Ctr Mannheim, Dept Trauma Surg, D-68167 Mannheim, Germany
[3] Heidelberg Univ, Univ Med Ctr Mannheim, Dept Obstet & Gynaecol, D-68167 Mannheim, Germany
来源
ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK | 2014年 / 24卷 / 03期
关键词
intraoperative radiotherapy; Intrabeam; radiation protection; SOCIETY CONSENSUS GUIDELINES; AMERICAN BRACHYTHERAPY; BREAST-CANCER; INTERSTITIAL RADIOSURGERY; RADIOTHERAPY-TARGIT; KYPHO-IORT; KYPHOPLASTY; DEVICE; DOSIMETRY;
D O I
10.1016/j.zemedi.2013.10.006
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Intraoperative radiotherapy (IORT) using the INTRABEAM (R) system promises a flexible use regarding radiation protection compared to other approaches such as electron treatment or HDR brachytherapy with Ir-192 or Co-60. In this study we compared dose rate measurements of breast- and Kypho-IORT with C-arm fluoroscopy which is needed to estimate radiation protection areas. Materials and Methods: C-arm fluoroscopy, breast- and Kypho-IORTs were performed using phantoms (silicon breast or bucket of water). Dose rates were measured at the phantom's surface, at 30 cm, 100 cm and 200 cm distance. Those measurements were confirmed during 10 Kypho-IORT and 10 breast-IORT patient treatments. Results: The measured dose rates were in the same magnitude for all three paradigms and ranges from 20 mu Sv/h during a simulated breast-IORT at two meter distance up to 64 mSv/h directly at the surface of a simulated Kypho-IORT. Those measurements result in a circle of controlled area (yearly doses >6 mSv) for each paradigm of about 4 m +/- 2 m. Discussion/Conclusions: All three paradigms show comparable dose rates which implies that the radiation protection is straight forward and confirms the flexible use of the INTRABEAM (R) system.
引用
收藏
页码:243 / 251
页数:9
相关论文
共 50 条
  • [31] Improved normal tissue protection by proton and X-ray microchannels compared to homogeneous field irradiation
    Girst, S.
    Marx, C.
    Braeuer-Krisch, E.
    Bravin, A.
    Bartzsch, S.
    Oelfke, U.
    Greubel, C.
    Reindl, J.
    Siebenwirth, C.
    Zlobinskaya, O.
    Multhoff, G.
    Dollinger, G.
    Schmid, T. E.
    Wilkens, J. J.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2015, 31 (06): : 615 - 620
  • [32] Modified design of x-ray protective clothing to enhance radiation protection for interventional radiologists
    Choi, Tae Won
    Chung, Jin Wook
    Kwon, Yohan
    MEDICAL PHYSICS, 2023, 50 (06) : 3825 - 3832
  • [33] Ionizing Radiation Dose Exposure to the Ocular Region of Pain Physicians During C-arm Guided Pain Interventions
    Kelly, Raymond
    McMahon, Aisling
    Hegarty, Dominic
    PAIN PHYSICIAN, 2018, 21 (05) : E523 - E532
  • [34] Status of Radiation Protection of Medical X-Ray Facilities in Greater Accra Region, Ghana
    Emi-Reynolds, Geoffrey
    Mensah, Cynthia Kaikor
    Gyekye, Prince Kwabena
    Amekudzie, Ann Etornam
    HEALTH PHYSICS, 2012, 102 (05): : S63 - S66
  • [35] Distribution of scatter radiation by C-arm cone-beam computed tomography in angiographic suite: measurement of doses and effectiveness of protection devices
    Yamaji, Mayako
    Ishiguchi, Tsuneo
    Koyama, Shuji
    Ikeda, Shuji
    Kitagawa, Akira
    Hagihara, Makiyo
    Itoh, Yuji
    Nakamura, Masaru
    Ota, Toyohiro
    Suzuki, Kojiro
    NAGOYA JOURNAL OF MEDICAL SCIENCE, 2021, 83 (02): : 277 - 286
  • [36] Surgical Team Radiation Exposure from C-arm during Orthopedic Surgical Procedures
    Almanie, Ahlam
    Bachari, Shima Seneysel
    JOURNAL OF THE LIAQUAT UNIVERSITY OF MEDICAL AND HEALTH SCIENCES, 2022, 21 (03): : 171 - 175
  • [37] Hygienic requirements for methods of calculation of radiation protection, radiation monitoring, and monitoring of maintenance parameters of X-ray equipment
    E. P. Ermolina
    V. A. Pertsov
    Biomedical Engineering, 2003, 37 (5) : 246 - 248
  • [38] Radiation dose reduction capabilities of a new C-arm system with optimized hard- and software
    Javor, Domagoj
    Moyses, Johanna
    Loewe, Christian
    Schernthaner, Ruediger E.
    EUROPEAN JOURNAL OF RADIOLOGY, 2021, 134
  • [39] The Radiation Shielding Design of X-Ray Velocimeter
    Bo, Yang
    2016 3RD INTERNATIONAL CONFERENCE ON SYSTEMS AND INFORMATICS (ICSAI), 2016, : 650 - 654
  • [40] Calculated and measured radiation dose for the low energy xoft axxent eBT X-ray source
    Can, Suemeyra
    Atilla, Oezge
    Karacetin, Didem
    BMC RESEARCH NOTES, 2023, 16 (01)