Radiation protection for an intraoperative X-ray source compared to C-arm fluoroscopy

被引:14
|
作者
Schneider, Frank [1 ]
Clausen, Sven [1 ]
Jahnke, Anika [1 ]
Steil, Volker [1 ]
Bludau, Frederic [2 ]
Suetterlin, Marc [3 ]
Obertacke, Udo [2 ]
Wenz, Frederik [1 ]
机构
[1] Heidelberg Univ, Univ Med Ctr Mannheim, Dept Radiat Oncol, D-68167 Mannheim, Germany
[2] Heidelberg Univ, Univ Med Ctr Mannheim, Dept Trauma Surg, D-68167 Mannheim, Germany
[3] Heidelberg Univ, Univ Med Ctr Mannheim, Dept Obstet & Gynaecol, D-68167 Mannheim, Germany
来源
ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK | 2014年 / 24卷 / 03期
关键词
intraoperative radiotherapy; Intrabeam; radiation protection; SOCIETY CONSENSUS GUIDELINES; AMERICAN BRACHYTHERAPY; BREAST-CANCER; INTERSTITIAL RADIOSURGERY; RADIOTHERAPY-TARGIT; KYPHO-IORT; KYPHOPLASTY; DEVICE; DOSIMETRY;
D O I
10.1016/j.zemedi.2013.10.006
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Intraoperative radiotherapy (IORT) using the INTRABEAM (R) system promises a flexible use regarding radiation protection compared to other approaches such as electron treatment or HDR brachytherapy with Ir-192 or Co-60. In this study we compared dose rate measurements of breast- and Kypho-IORT with C-arm fluoroscopy which is needed to estimate radiation protection areas. Materials and Methods: C-arm fluoroscopy, breast- and Kypho-IORTs were performed using phantoms (silicon breast or bucket of water). Dose rates were measured at the phantom's surface, at 30 cm, 100 cm and 200 cm distance. Those measurements were confirmed during 10 Kypho-IORT and 10 breast-IORT patient treatments. Results: The measured dose rates were in the same magnitude for all three paradigms and ranges from 20 mu Sv/h during a simulated breast-IORT at two meter distance up to 64 mSv/h directly at the surface of a simulated Kypho-IORT. Those measurements result in a circle of controlled area (yearly doses >6 mSv) for each paradigm of about 4 m +/- 2 m. Discussion/Conclusions: All three paradigms show comparable dose rates which implies that the radiation protection is straight forward and confirms the flexible use of the INTRABEAM (R) system.
引用
收藏
页码:243 / 251
页数:9
相关论文
共 50 条
  • [21] A Highly Versatile X-ray and Electron Beam Diamond Dosimeter for Radiation Therapy and Protection
    Pettinato, Sara
    Girolami, Marco
    Stravato, Antonella
    Serpente, Valerio
    Musio, Daniela
    Rossi, Maria C.
    Trucchi, Daniele M.
    Olivieri, Riccardo
    Salvatori, Stefano
    MATERIALS, 2023, 16 (02)
  • [22] Chromosomal aberrations in C-arm fluoroscopy, CT-scan, lithotripsy, and digital radiology staff
    Shafiee, Mohsen
    Borzoueisileh, Sajad
    Rashidfar, Razieh
    Dehghan, Maryam
    Sisakht, Zahra Jaafarian
    MUTATION RESEARCH-GENETIC TOXICOLOGY AND ENVIRONMENTAL MUTAGENESIS, 2020, 849
  • [23] X-ray radiation protection aspects during ultrashort laser processing
    Legall, Herbert
    Schwanke, Christoph
    Bonse, Joern
    Krueger, Joerg
    JOURNAL OF LASER APPLICATIONS, 2020, 32 (02)
  • [24] Radiation Protection on Patient Dosimetry Thorax X-Ray using Thermolumineseent Dosimeter (TLD) Chips
    Triandini, Annisa Retno
    Fathom, Muhammad
    PROCEEDINGS OF 2017 5TH INTERNATIONAL CONFERENCE ON INSTRUMENTATION, COMMUNICATIONS, INFORMATION TECHNOLOGY, AND BIOMEDICAL ENGINEERING (ICICI-BME): SCIENCE AND TECHNOLOGY FOR A BETTER LIFE, 2017, : 85 - 90
  • [25] Radiation hygiene in medical X-ray imaging
    Brix, G.
    Veit, R.
    Haeusler, U.
    RADIOLOGE, 2010, 50 (10): : 913 - 925
  • [26] Seed localization in Ultrasound and Registration to C-Arm Fluoroscopy Using Matched Needle Tracks for Prostate Brachytherapy
    Moradi, Mehdi
    Mahdavi, S. Sara
    Dehghan, Ehsan
    Lobo, Julio R.
    Deshmukh, Sanchit
    Morris, William James
    Fichtinger, Gabor
    Salcudean, Septimiu E.
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2012, 59 (09) : 2558 - 2567
  • [27] Radiation Protection Evaluation of Medical X-ray Imaging Centers in Qazvin, Iran
    Esfahani, Azam Janati
    Cheraghi, Susan
    HEALTH PHYSICS, 2021, 121 (05): : 454 - 462
  • [28] X-ray spectrometry for calculating conversion coefficients from air kerma to operational quantities in radiation protection
    Plagnard, Johann
    Lefevre, Jeremie
    JOURNAL OF RADIOLOGICAL PROTECTION, 2024, 44 (03)
  • [29] SILICONE COMPOSITES FOR X-RAY PROTECTION
    Jankauskaite, Virginija
    Griskonis, Egidijus
    Lisauskaite, Aiste
    Plaipaite-Nalivaiko, Rita
    Kleveckas, Tadas
    MEDICAL PHYSICS IN THE BALTIC STATES, 2013, : 173 - 177
  • [30] Fundamental study on diagnostic reference level quantities for endoscopic retrograde cholangiopancreatography using a C-arm fluoroscopy system
    Ishii, Hiroki
    Chida, Koichi
    Inaba, Yohei
    Abe, Keisuke
    Onodera, Shu
    Zuguchi, Masayuki
    JOURNAL OF RADIOLOGICAL PROTECTION, 2023, 43 (04)