Radiation protection for an intraoperative X-ray source compared to C-arm fluoroscopy

被引:14
|
作者
Schneider, Frank [1 ]
Clausen, Sven [1 ]
Jahnke, Anika [1 ]
Steil, Volker [1 ]
Bludau, Frederic [2 ]
Suetterlin, Marc [3 ]
Obertacke, Udo [2 ]
Wenz, Frederik [1 ]
机构
[1] Heidelberg Univ, Univ Med Ctr Mannheim, Dept Radiat Oncol, D-68167 Mannheim, Germany
[2] Heidelberg Univ, Univ Med Ctr Mannheim, Dept Trauma Surg, D-68167 Mannheim, Germany
[3] Heidelberg Univ, Univ Med Ctr Mannheim, Dept Obstet & Gynaecol, D-68167 Mannheim, Germany
来源
ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK | 2014年 / 24卷 / 03期
关键词
intraoperative radiotherapy; Intrabeam; radiation protection; SOCIETY CONSENSUS GUIDELINES; AMERICAN BRACHYTHERAPY; BREAST-CANCER; INTERSTITIAL RADIOSURGERY; RADIOTHERAPY-TARGIT; KYPHO-IORT; KYPHOPLASTY; DEVICE; DOSIMETRY;
D O I
10.1016/j.zemedi.2013.10.006
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Intraoperative radiotherapy (IORT) using the INTRABEAM (R) system promises a flexible use regarding radiation protection compared to other approaches such as electron treatment or HDR brachytherapy with Ir-192 or Co-60. In this study we compared dose rate measurements of breast- and Kypho-IORT with C-arm fluoroscopy which is needed to estimate radiation protection areas. Materials and Methods: C-arm fluoroscopy, breast- and Kypho-IORTs were performed using phantoms (silicon breast or bucket of water). Dose rates were measured at the phantom's surface, at 30 cm, 100 cm and 200 cm distance. Those measurements were confirmed during 10 Kypho-IORT and 10 breast-IORT patient treatments. Results: The measured dose rates were in the same magnitude for all three paradigms and ranges from 20 mu Sv/h during a simulated breast-IORT at two meter distance up to 64 mSv/h directly at the surface of a simulated Kypho-IORT. Those measurements result in a circle of controlled area (yearly doses >6 mSv) for each paradigm of about 4 m +/- 2 m. Discussion/Conclusions: All three paradigms show comparable dose rates which implies that the radiation protection is straight forward and confirms the flexible use of the INTRABEAM (R) system.
引用
收藏
页码:243 / 251
页数:9
相关论文
共 50 条
  • [1] RADIATION EXPOSURE DURING SPINE SURGERY USING C-ARM FLUOROSCOPY
    Cristante, Alexandre Fogaca
    Barbieri, Fabio
    Rodrigues da Silva, Almy Anacleto
    Dellamano, Jose Claudio
    ACTA ORTOPEDICA BRASILEIRA, 2019, 27 (01): : 46 - 49
  • [2] Quality assurance and independent dosimetry for an intraoperative x-ray device
    Eaton, D. J.
    MEDICAL PHYSICS, 2012, 39 (11) : 6908 - 6920
  • [3] C-arm Positioning Is a Significant Source of Radiation in Spine Surgery
    Reiser, Elizabeth W.
    Desai, Rupen
    Byrd, Sarah A.
    Farber, Harrison
    Chi, Deborah
    Idler, Cary S.
    Isaacs, Robert E.
    SPINE, 2017, 42 (09) : 707 - 710
  • [4] Radiation Exposure of the Hand and Chest during C-arm Fluoroscopy-Guided Procedures
    Jung, Cheol Hee
    Ryu, Jae Sung
    Baek, Seung Woo
    Oh, Ji Hye
    Woo, Nam Sik
    Kim, Hae Kyoung
    Kim, Jae Hun
    KOREAN JOURNAL OF PAIN, 2013, 26 (01) : 51 - 56
  • [5] Radiation Protection of X-Ray Rooms
    E. G. Chikirdin
    Biomedical Engineering, 2001, 35 (2) : 60 - 64
  • [6] Comparison of Radiation Exposure from Fixed Table Fluoroscopy to a Portable C-Arm During Ureteroscopy
    Cabrera, Fernando J.
    Shin, Richard H.
    Waisanen, Kyle M.
    Nguyen, Giao
    Wang, Chu
    Scales, Charles D.
    Ferrandino, Michael N.
    Preminger, Glenn M.
    Yoshizumi, Terry T.
    Lipkin, Michael E.
    JOURNAL OF ENDOUROLOGY, 2017, 31 (09): : 835 - 840
  • [7] Real-time, ray casting-based scatter dose estimation for c-arm x-ray system
    Alnewaini, Zaid
    Langer, Eric
    Schaber, Philipp
    David, Matthias
    Kretz, Dominik
    Steil, Volker
    Hesser, Juergen
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2017, 18 (02): : 144 - 153
  • [8] Investigation of radiation dose around C-arm fluoroscopy and relevant cancer risk to operating room staff
    Robatjazi, Mostafa
    Dareyni, Amir
    Baghani, Hamid Reza
    Hosseinzade, Mohammad
    Akbarzadeh, Roya
    Mehrpoyan, Mohammad
    RADIATION AND ENVIRONMENTAL BIOPHYSICS, 2022, 61 (02) : 301 - 307
  • [9] Investigation of radiation dose around C-arm fluoroscopy and relevant cancer risk to operating room staff
    Mostafa Robatjazi
    Amir Dareyni
    Hamid Reza Baghani
    Mohammad Hosseinzade
    Roya Akbarzadeh
    Mohammad Mehrpoyan
    Radiation and Environmental Biophysics, 2022, 61 : 301 - 307
  • [10] Directional vector visualization of scattered rays in mobile c-arm fluoroscopy
    Hizukuri, Kyoko
    Fujibuchi, Toshioh
    Arakawa, Hiroyuki
    RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2024, 17 (01) : 288 - 296