Seismic behavior of FRP-upgraded exterior RC beam-column joints
被引:0
|
作者:
Al-Salloum, Y. A.
论文数: 0引用数: 0
h-index: 0
机构:
King Saud Univ, Dept Civil Engn, Riyadh, Saudi ArabiaKing Saud Univ, Dept Civil Engn, Riyadh, Saudi Arabia
Al-Salloum, Y. A.
[1
]
Alsayed, S. H.
论文数: 0引用数: 0
h-index: 0
机构:
King Saud Univ, Dept Civil Engn, Riyadh, Saudi ArabiaKing Saud Univ, Dept Civil Engn, Riyadh, Saudi Arabia
Alsayed, S. H.
[1
]
Almusallam, T. H.
论文数: 0引用数: 0
h-index: 0
机构:
King Saud Univ, Dept Civil Engn, Riyadh, Saudi ArabiaKing Saud Univ, Dept Civil Engn, Riyadh, Saudi Arabia
Almusallam, T. H.
[1
]
Siddiqui, N. A.
论文数: 0引用数: 0
h-index: 0
机构:
King Saud Univ, Dept Civil Engn, Riyadh, Saudi ArabiaKing Saud Univ, Dept Civil Engn, Riyadh, Saudi Arabia
Siddiqui, N. A.
[1
]
机构:
[1] King Saud Univ, Dept Civil Engn, Riyadh, Saudi Arabia
来源:
CONCRETE REPAIR, REHABILITATION AND RETROFITTING II
|
2009年
关键词:
D O I:
暂无
中图分类号:
TU [建筑科学];
学科分类号:
0813 ;
摘要:
Shear failure of exterior beam-column joints is identified as the principal cause of collapse of many moment-resisting frame buildings during recent earthquakes. Effective and economical strengthening techniques to upgrade joint shear-resistance and ductility in existing structures are needed. In this paper, efficiency and effectiveness of Carbon Fiber Reinforced Polymers (CFRP) in upgrading the shear strength and ductility of seismically deficient exterior beam-column joints have been studied. For this purpose, two reinforced concrete exterior beam-column sub-assemblages were constructed with non-optimal design parameters (inadequate joint shear strength with no transverse reinforcement) representing pre-seismic code design construction practice of joints and encompassing the vast majority of existing beam-column connections. Out of these two, one specimen was used as baseline specimen (control specimen) and the other one was strengthened with CFRP sheets (strengthened specimen). These two sub-assemblages were Subjected to cyclic lateral load histories so as to provide the equivalent of severe earthquake damage. The damaged control specimen was then repaired using CFRP sheets. This repaired specimen was subjected to the similar cyclic lateral load history and its response history was obtained. Response histories of control, repaired and strengthened specimens were then compared. The results were compared through hysteretic loops, load-displacement envelopes, ductility and stiffness degradation. The comparison shows that CFRP sheets improve the shear resistance of the joint and increase its ductility.