Transmission geometry laser ablation into a non-contact liquid vortex capture probe for mass spectrometry imaging

被引:32
作者
Ovchinnikova, Olga S. [1 ]
Bhandari, Deepak [1 ]
Lorenz, Matthias [1 ]
Van Berkel, Gary J. [1 ]
机构
[1] Oak Ridge Natl Lab, Div Chem Sci, Organ & Biol Mass Spectrometry Grp, Oak Ridge, TN 37831 USA
关键词
THIN-LAYER-CHROMATOGRAPHY; MATRICES; EMITTER;
D O I
10.1002/rcm.6946
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
RATIONALE: Capture of material from a laser ablation plume into a continuous flow stream of solvent provides the means for uninterrupted sampling, transport and ionization of collected material for coupling with mass spectral analysis. Reported here is the use of vertically aligned transmission geometry laser ablation in combination with a new non-contact liquid vortex capture probe coupled with electrospray ionization for spot sampling and chemical imaging with mass spectrometry. METHODS: A vertically aligned continuous flow liquid vortex capture probe was positioned directly underneath a sample surface in a transmission geometry laser ablation (355 nm, 10 Hz, 7 ns pulse width) set up to capture into solution the ablated material. The outlet of the vortex probe was coupled to the Turbo V (TM) ion source of an AB SCIEX TripleTOF 5600+ mass spectrometer. System operation and performance metrics were tested using inked patterns and thin tissue sections. Glass slides and slides designed especially for laser capture microdissection, viz., DIRECTOR (R) slides and PEN 1.0 (polyethylene naphthalate) membrane slides, were used as sample substrates. RESULTS: The estimated capture efficiency of laser-ablated material was 24%, which was enabled by the use of a probe with large liquid surface area (similar to 2.8 mm(2)) and with gravity to help direct ablated material vertically down towards the probe. The swirling vortex action of the liquid surface potentially enhanced capture and dissolution not only of particulates, but also of gaseous products of the laser ablation. The use of DIRECTOR (R) slides and PEN 1.0 (polyethylene naphthalate) membrane slides as sample substrates enabled effective ablation of a wide range of sample types (basic blue 7, polypropylene glycol, insulin and cyctochrome c) without photodamage using a UV laser. Imaging resolution of about 6 m was demonstrated for stamped ink on DIRECTOR (R) slides based on the ability to distinguish features present both in the optical and in the chemical image. This imaging resolution was 20 times better than the previous best reported results with laser ablation/liquid sample capture mass spectrometry imaging. Using thin sections of brain tissue the chemical image of a selected lipid was obtained with an estimated imaging resolution of about 50 mu m. CONCLUSIONS: A vertically aligned, transmission geometry laser ablation liquid vortex capture probe, electrospray ionization mass spectrometry system provides an effective means for spatially resolved spot sampling and imaging with mass spectrometry. Published in 2014. This article is a U.S. Government work and is in the public domain in the USA.
引用
收藏
页码:1665 / 1673
页数:9
相关论文
共 23 条
[11]   Laser microdissection and atmospheric pressure chemical ionization mass spectrometry coupled for multimodal imaging [J].
Lorenz, Matthias ;
Ovchinnikova, Olga S. ;
Kertesz, Vilmos ;
Van Berkel, Gary J. .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2013, 27 (13) :1429-1436
[12]   Imaging of lipid species by MALDI mass spectrometry [J].
Murphy, Robert C. ;
Hankin, Joseph A. ;
Barkley, Robert M. .
JOURNAL OF LIPID RESEARCH, 2009, 50 :S317-S322
[13]   Laser Ablation Sampling of Materials Directly into the Formed Liquid Microjunction of a Continuous Flow Surface Sampling Probe/Electrospray Ionization Emitter for Mass Spectral Analysis and Imaging [J].
Ovchinnikova, Olga S. ;
Lorenz, Matthias ;
Kertesz, Vilmos ;
Van Berkel, Gary J. .
ANALYTICAL CHEMISTRY, 2013, 85 (21) :10211-10217
[14]   Combining transmission geometry laser ablation and a non-contact continuous flow surface sampling probe/electrospray emitter for mass spectrometry based chemical imaging [J].
Ovchinnikova, Olga S. ;
Kertesz, Vilmos ;
Van Berkel, Gary J. .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2011, 25 (24) :3735-3740
[15]   Combining Laser Ablation/Liquid Phase Collection Surface Sampling and High-Performance Liquid Chromatography-Electrospray Ionization-Mass Spectrometry [J].
Ovchinnikova, Olga S. ;
Kertesz, Vilmos ;
Van Berkel, Gary J. .
ANALYTICAL CHEMISTRY, 2011, 83 (06) :1874-1878
[16]   Molecular Surface Sampling and Chemical Imaging using Proximal Probe Thermal Desorption/Secondary Ionization Mass Spectrometry [J].
Ovchinnikova, Olga S. ;
Kertesz, Vilmos ;
Van Berkel, Gary J. .
ANALYTICAL CHEMISTRY, 2011, 83 (02) :598-603
[17]   Ambient laser ablation sampling for capillary electrophoresis mass spectrometry [J].
Park, Sung-Gun ;
Murray, Kermit K. .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2013, 27 (15) :1673-1680
[18]   Infrared laser ablation sample transfer for on-line liquid chromatography electrospray ionization mass spectrometry [J].
Park, Sung-Gun ;
Murray, Kermit K. .
JOURNAL OF MASS SPECTROMETRY, 2012, 47 (10) :1322-1326
[19]   Infrared Laser Ablation Sample Transfer for MALDI and Electrospray [J].
Park, Sung-Gun ;
Murray, Kermit King .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2011, 22 (08) :1352-1362
[20]   COMPARISON OF RHODAMINE DYES AS MATRICES FOR MATRIX-ASSISTED LASER DESORPTION IONIZATION MASS-SPECTROMETRY [J].
TANG, K ;
ALLMAN, SL ;
JONES, RB ;
CHEN, CH .
ORGANIC MASS SPECTROMETRY, 1992, 27 (12) :1389-1392