Cytotoxicity of the Ga-containing coatings on biodegradable magnesium alloys

被引:20
作者
Nguyen, Anika [1 ]
Kunert, Maik [2 ]
Hort, Norbert [3 ]
Schrader, Christian [4 ]
Weisser, Juergen [5 ]
Schmidt, Juergen [4 ]
机构
[1] Ernst Abbe Univ Appl Sci Jena, Dept Med Engn & Biotechnol, Jena, Germany
[2] Ernst Abbe Univ Appl Sci Jena, Dept SciTec, Jena, Germany
[3] Helmholtz Zentrum Geesthacht, Inst Mat Res, Ctr Mat & Coastal Res, D-21502 Geesthacht, Germany
[4] Innovent Technol Dev, Dept Electrochem, Jena, Germany
[5] Innovent Technol Dev, Dept Biomat, Jena, Germany
关键词
biocompatibility; coatings; magnesium alloys; resorbable implants; surface characterization; IN-VIVO; CALCIUM; DEGRADATION; IMPLANTS; GADOLINIUM; ALUMINUM; BEHAVIOR; ARTERY; IRON;
D O I
10.1680/si.13.00035
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Biodegradable magnesium alloys, Mg-0.8wt% Ca and Mg-10wt% Gd, have been coated with gallium-containing electrolyte using plasma electrolytic oxidation (PEO). Thus, the PEO procedure is used as a synthesis tool, to create an appropriate content in the layers. This is a first article on the examination of such layers. One part of the gallium-coated samples was additionally sealed with biodegradable poly(L-lactide-co-caprolactone) (PLLC). Gallium content, morphology and thickness of the coatings were evaluated. Special focus was set in relation to the cytotoxicity of the coating, on the two different magnesium alloys and the additional sealing with PLLC. Cytotoxicity was tested using live/dead staining of MC3T3-E1 fibroblasts and by WST-1 assay, cell differentiation by alkaline phosphatase measurement. It could be shown that the gallium-ion concentration in the PEO layer was higher for Mg-10wt% Gd than that of Mg-0.8wt% Ca, which caused a significant difference in the cytotoxic effects toward MC3T3-E1 cells. Still in all cytotoxic tests, Mg-10wt% Gd showed no to low cytotoxic levels, whereby Mg-0.8wt% Ca showed moderate results. Furthermore, it could be proved that an additional PLLC sealing benefits the cell adhesion and thus promotes the cytocompatibility of the coating.
引用
收藏
页码:10 / 19
页数:10
相关论文
共 38 条
[1]   Biocorrosion behavior and cell viability of adhesive polymer coated magnesium based alloys for medical implants [J].
Abdal-hay, Abdalla ;
Dewidar, Montasser ;
Lim, Jae Kyoo .
APPLIED SURFACE SCIENCE, 2012, 261 :536-546
[2]  
[Anonymous], BIOCHEMICA
[3]  
[Anonymous], 1996, 1099312 ISO
[4]  
[Anonymous], [No title captured]
[5]   Association of gadolinium based magnetic resonance imaging contrast agents and nephrogenic systemic fibrosis [J].
Bhave, Gautam ;
Lewis, Julia B. ;
Chang, Sam S. .
JOURNAL OF UROLOGY, 2008, 180 (03) :830-835
[6]   GALLIUM INCREASES BONE CALCIUM AND CRYSTALLITE PERFECTION OF HYDROXYAPATITE [J].
BOCKMAN, RS ;
BOSKEY, AL ;
BLUMENTHAL, NC ;
ALCOCK, NW ;
WARRELL, RP .
CALCIFIED TISSUE INTERNATIONAL, 1986, 39 (06) :376-381
[7]   Prolonged exposure to low levels of aluminum leads to changes associated with brain aging and neurodegeneration [J].
Bondy, Stephen C. .
TOXICOLOGY, 2014, 315 :1-7
[8]   New approaches in evaluating metallic candidates for bioabsorbable stents [J].
Bowen, Patrick K. ;
Drelich, Jaroslaw ;
Buxbaum, Robert E. ;
Rajachar, Rupak M. ;
Goldman, Jeremy .
EMERGING MATERIALS RESEARCH, 2012, 1 (05) :237-255
[9]   Using gadolinium to identify stretch-activated channels: technical considerations [J].
Caldwell, RA ;
Clemo, HF ;
Baumgarten, CM .
AMERICAN JOURNAL OF PHYSIOLOGY-CELL PHYSIOLOGY, 1998, 275 (02) :C619-C621
[10]   Bioresorbable Drug-Eluting Magnesium-Alloy Scaffold for Treatment of Coronary Artery Disease [J].
Campos, Carlos M. ;
Muramatsu, Takashi ;
Iqbal, Javaid ;
Zhang, Ya-Jun ;
Onuma, Yoshinobu ;
Garcia-Garcia, Hector M. ;
Haude, Michael ;
Lemos, Pedro A. ;
Warnack, Boris ;
Serruys, Patrick W. .
INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2013, 14 (12) :24492-24500