Thermal performance and parameter analysis of a U-pipe evacuated solar tube collector

被引:76
作者
Gao, Y. [1 ,2 ]
Fan, R. [3 ]
Zhang, X. Y. [4 ]
An, Y. J. [2 ]
Wang, M. X. [1 ]
Gao, Y. K. [1 ]
Yu, Y. [1 ]
机构
[1] Beijing Univ Civil Engn & Architecture, Beijing Key Lab Heating Gas Supply Ventilating &, Beijing 100044, Peoples R China
[2] Beijing Univ Civil Engn & Architecture, Beijing Key Lab Green Bldg & Energy Efficient Tec, Beijing 100044, Peoples R China
[3] Tongji Univ, Chinese German Univ Appl Sci, Shanghai 201804, Peoples R China
[4] Natl Ctr Qual Supervis & Testing Solar Heating Sy, Beijing 100013, Peoples R China
关键词
U-pipe evacuated solar tube collector; Thermal performance; Meteorological condition adaptation; Design parameters; WATER-HEATERS;
D O I
10.1016/j.solener.2014.05.023
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper proposes a mathematical model for predicting the thermal performance of U-pipe evacuated solar tube (UpEST) collector, which takes into account the temperature distribution along the tube axis and radius. Furthermore, the modeling predictions were validated using experimental data. Theoretical results agreed well with the measured results that validated the feasibility of the mathematical model. The dependence of the thermal efficiency on meteorological conditions and important tube design parameters, including tube size, thermal characteristics (flow rate, heat loss coefficient, absorption coefficient of the selective absorbing coating), was investigated. In particular, the adaptation of collector thermal parameters to meteorological conditions was analyzed. The analysis results will be helpful for UpEST collector optimization design and application. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:714 / 727
页数:14
相关论文
共 20 条
[1]  
[Anonymous], 2005, 10749 GBT
[2]  
[Anonymous], 1995, 9806 ISO
[3]   Performance of water-in-glass evacuated tube solar water heaters [J].
Budihardjo, I. ;
Morrison, G. L. .
SOLAR ENERGY, 2009, 83 (01) :49-56
[4]   Experimental study of flow rates through inclined open thermosyphons [J].
Gaa, FO ;
Behnia, M ;
Morrison, GL .
SOLAR ENERGY, 1996, 57 (05) :401-408
[5]  
Gu Y., 1998, ASHRAE T, V104, P347
[6]   A three-dimensional performance analysis of all-glass vacuum tubes with coaxial fluid conduit [J].
Han, Hyunjoo ;
Kim, Jeong Tai ;
Ahn, Hyun Tae ;
Lee, Sang Jin .
INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2008, 35 (05) :589-596
[7]   Thermal performances comparisons of the glass evacuated tube solar collectors with shapes of absorber tube [J].
Kim, Yong ;
Seo, Taebeom .
RENEWABLE ENERGY, 2007, 32 (05) :772-795
[8]   Theoretical and experimental investigation of the filled-type evacuated tube solar collector with U tube [J].
Liang, Ruobing ;
Ma, Liangdong ;
Zhang, Jili ;
Zhao, Dan .
SOLAR ENERGY, 2011, 85 (09) :1735-1744
[9]   Thermal performance analysis of the glass evacuated tube solar collector with U-tube [J].
Ma, Liangdong ;
Lu, Zhen ;
Zhang, Jili ;
Liang, Ruobing .
BUILDING AND ENVIRONMENT, 2010, 45 (09) :1959-1967
[10]   Measurement and simulation of flow rate in a water-in-glass evacuated tube solar water heater [J].
Morrison, GL ;
Budihardjo, I ;
Behnia, M .
SOLAR ENERGY, 2005, 78 (02) :257-267