Fault Ride-Through Capability Improvement of Grid Connected PV System Using Dynamic Voltage Restorer

被引:8
作者
AbuHussein, Ahmed [1 ]
Sadi, Mohammad Ashraf Hossain [2 ]
机构
[1] Gannon Univ, Dept Elect & Comp Engn, Erie, PA 16541 USA
[2] Univ Cent Missouri, Sch Technol, Warrensburg, MO USA
关键词
dynamic voltage restorer (DVR); fault ride-through (FRT); photovoltaic (PV); series dynamic braking resistor (SDBR); symmetrical; asymmetrical faults;
D O I
10.1080/15325008.2020.1854374
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
When a fault occurs at a grid-connected photovoltaic (PV) system, the grid voltage drops significantly, and this causes a spike in the DC link voltage. The high DC voltage, in turn, causes faults in the Power-Electronics inverters and choppers. In addition, PV plants form a significant portion of modern power systems and disconnecting them during faults (as conventional) is no longer an option. This work proposes the dynamic voltage restorer (DVR) to improve the fault ride-through (FRT) capability of PV systems under a three-phase-to-ground fault. In order to evaluate the effectiveness of the proposed DVR method, its performance is compared with that of the series dynamic braking resistor (SDBR). The comparison is made in terms of performance and control complexity. Simulation results show that the DVR can improve the FRT capability seamlessly. Also, despite its higher cost and controller complexity, the proposed DVR outperforms the SDBR in all aspects.
引用
收藏
页码:1296 / 1307
页数:12
相关论文
共 34 条
[1]  
A El-Gammal M., 2011, INT J ELECT ENG INFO, V3, DOI [10.15676/ijeei.2011.3.1.1, DOI 10.15676/IJEEI.2011.3.1.1]
[2]  
Bollen M.H. J., 2002, Understanding power quality problems: voltage sags and interruptions, DOI [10.1109/9780470546840.ch1, DOI 10.1109/9780470546840.CH1]
[3]  
Causebrook A., 2008, FAULT RIDE THROUGH W
[4]   Fault ride-through of large wind farms using series dynamic braking resistors (March 2007) [J].
Causebrook, Andrew ;
Atkinson, David J. ;
Jack, Alan G. .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2007, 22 (03) :966-975
[5]  
Driesen J, 2006, IEEE POWER ENG SOC, P3848
[6]   Fault ride through capability for grid interfacing large scale PV power plants [J].
El Moursi, Mohamed Shawky ;
Xiao, Weidong ;
Kirtley, Jim L., Jr. .
IET GENERATION TRANSMISSION & DISTRIBUTION, 2013, 7 (09) :1027-1036
[7]   Comparison of photovoltaic array maximum power point tracking techniques [J].
Esram, Trishan ;
Chapman, Patrick L. .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2007, 22 (02) :439-449
[8]   Integrated Control Technique for Compliance of Solar Photovoltaic Installation Grid Codes [J].
Garcia-Gracia, Miguel ;
El Halabi, Nabil ;
Ajami, Hassan ;
Paz Comech, Maria .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2012, 27 (03) :792-798
[9]  
HOSSEINI KA, 2014, INT J DISASTER RISK, P1
[10]  
Hussein A.A., 2014, P IEEE PES T D C EXP, P1