FDTD surge analysis of grounding electrodes considering soil ionization

被引:19
|
作者
Otani, Ken [1 ]
Baba, Yoshihiro [1 ]
Nagaoka, Naoto [1 ]
Ametani, Akihiro [1 ]
Itamoto, Naoki [2 ]
机构
[1] Doshisha Univ, Dept Elect Engn, Kyoto 6100321, Japan
[2] Hokuriku Elect Power Co Inc, Inst Res & Dev, Toyama 9308686, Japan
关键词
Grounding electrode; Soil ionization; Finite-difference time-domain method; Lightning; MODEL; SIMULATION; SYSTEMS; TRANSIENTS; BOUNDARY; BEHAVIOR; CURRENTS;
D O I
10.1016/j.epsr.2014.02.032
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Recently, Ala et al. (2008) [7] have proposed a soil ionization model, on the basis of the dynamic soil-resistivity model of Liew and Darveniza (1974) [16], for finite-difference time-domain (FDTD) computations, and tested the validity of the model against experiments on a single vertical grounding conductor. In the model, the resistivity of each soil-representing cell is controlled by the instantaneous value of the electric field there and time. In this paper, in order to test the validity of this model more thoroughly, it has been applied to analyzing the surge responses of different grounding electrodes: a horizontal grounding conductor of lengths 8.1 m and 34 m, a vertical grounding conductor of lengths 1 m and 1.5 m, and four parallel vertical conductors of length 3.05 m, buried in different-resistivity soils. The FDTD-computed responses agree reasonably well with the corresponding ones measured by Sekioka et al. (1998) [17], Asaoka et al. (2005) [19], Geri et al. (1992) [23], and Bellaschi et al. (1942) [24]. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:171 / 179
页数:9
相关论文
共 50 条
  • [21] Transient characteristics of grounding grid of substation when considering the soil ionization
    Chen, You-Jun
    Wang, Feng-Hua
    Jin, Zhi-Jian
    Wu, Jian-Min
    Gaodianya Jishu/High Voltage Engineering, 2010, 36 (03): : 692 - 698
  • [22] Lightning impulse performances of grounding grids for substations considering soil ionization
    Zeng, Rong
    Gong, Xuehai
    He, Jinliang
    Zhang, Bo
    Gao, Yanqing
    IEEE TRANSACTIONS ON POWER DELIVERY, 2008, 23 (02) : 667 - 675
  • [23] Lightning electromagnetic field generated by grounding electrode considering soil ionization
    State Key Laboratory of Power Systems, Department of Electrical Engineering, Tsinghua University, Beijing 100084, China
    Prog. Nat. Sci., 2006, 9 (1002-1006):
  • [25] Calculating method of impulse characteristics of tower grounding devices considering soil ionization
    He, Jin-Liang
    Kong, Wei-Zheng
    Zhang, Bo
    Gaodianya Jishu/High Voltage Engineering, 2010, 36 (09): : 2107 - 2111
  • [26] Lightning electromagnetic environments of substation considering soil ionization around grounding systems
    Gao, YQ
    He, JL
    Chen, SM
    Zou, J
    Zeng, R
    Lung, XD
    POWERCON 2002: INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY, VOLS 1-4, PROCEEDINGS, 2002, : 2096 - 2100
  • [27] An Algorithm for the FDTD Modeling of Flat Electrodes in Grounding Systems
    Xiong, Run
    Chen, Bin
    Fang, Dagang
    IEEE TRANSACTIONS ON ANTENNAS AND PROPAGATION, 2014, 62 (01) : 345 - 353
  • [28] A simplified numerical modeling of the transient behavior of grounding systems considering soil ionization
    Nekhoul, B.
    Harrat, B.
    Boutadjine, A.
    Melit, M.
    ELECTRIC POWER SYSTEMS RESEARCH, 2022, 211
  • [29] Numerical analysis of transient performance of grounding systems considering soil ionization by coupling moment method with circuit theory
    Zhang, B
    He, JL
    Lee, JB
    Cui, X
    Zhao, ZB
    Zou, J
    Chang, SH
    IEEE TRANSACTIONS ON MAGNETICS, 2005, 41 (05) : 1440 - 1443
  • [30] Transient analysis of earthing electrodes considering soil ionization phenomenon under lightning impulse condition
    Sengar, Kaushal Pratap
    Chandrasekaran, Kandasamy
    ELECTRICAL ENGINEERING, 2024, 106 (03) : 3083 - 3096