Review of low voltage ride-through technology of doubly-fed induction generator

被引:15
|
作者
Niu, Lele [1 ,2 ]
Wang, Xiao [1 ,3 ]
Wu, Linlin [1 ,3 ]
Yang, Feng [2 ]
Xu, Man [1 ,3 ]
机构
[1] North China Elect Power Res Inst Co Ltd, State Grid Jibei Elect Power Co Ltd, Res Inst, Beijing, Peoples R China
[2] North China Elect Power Univ, Baoding, Peoples R China
[3] Grid Connected Operat Technol Wind Solar Storage, Beijing, Peoples R China
来源
JOURNAL OF ENGINEERING-JOE | 2019年 / 16期
关键词
asynchronous generators; wind power plants; HVDC power convertors; power generation control; voltage control; synchronisation; electric current control; voltage-source convertors; power generation reliability; machine control; coordinated control strategy; multiterminal VSC-HVDC system; islanded system; low voltage ride-through technology; doubly-fed induction generator; wind power development; DFIG; network synchronisation modes; AC network; two-terminal system; DC voltage control; multiterminal system; wind farm; power system reliability; LVRT technologies; multiterminal voltage-source convertor-high-voltage direct current system;
D O I
10.1049/joe.2018.8443
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In recent years, with the increasing of wind power development, the demand for low voltage ride-through (LVRT) technology was proposed to ensure the safe and reliable operation of the power system. The key issue of LVRT strategy for doubly-fed induction generator (DFIG) varies according to the network synchronisation modes. Firstly, the existed LVRT technologies when DFIG is connected to AC network are surveyed. Then relevant literatures about LVRT are summarised and analysed in regard to power surplus of two-terminal system and DC voltage control of multi-terminal system, respectively, when the wind farm is integrated with VSC-high-voltage direct current (HVDC). In the end, the coordinated control strategy of multi-terminal VSC-HVDC system and LVRT technology for islanded system are prospected in this study.
引用
收藏
页码:3106 / 3108
页数:3
相关论文
共 50 条
  • [21] The Requirements and Technical Analysis of Low Voltage Ride Through for the Doubly-Fed Induction Wind Turbines
    Niu, Chen-guang
    Liu, Guan-qi
    PROCEEDINGS OF INTERNATIONAL CONFERENCE ON SMART GRID AND CLEAN ENERGY TECHNOLOGIES (ICSGCE 2011), 2011, 12
  • [22] A Review on Fault Current Limiting Devices to Enhance the Fault Ride-Through Capability of the Doubly-Fed Induction Generator Based Wind Turbine
    Naderi, Seyed Behzad
    Davari, Pooya
    Zhou, Dao
    Negnevitsky, Michael
    Blaabjerg, Frede
    APPLIED SCIENCES-BASEL, 2018, 8 (11):
  • [23] Research on the Performance of Low Voltage Ride-Through for Doubly Fed Induction Generator Excited by Two-Stage Matrix Converter
    Deng, Wenlang
    Chen, Zhiyong
    Zhou, Liming
    Yang, Yu
    2009 IEEE 6TH INTERNATIONAL POWER ELECTRONICS AND MOTION CONTROL CONFERENCE, VOLS 1-4, 2009, : 1447 - 1452
  • [24] Fault ride-through capability enhancement of doubly-fed induction wind generators
    Mohseni, M.
    Islam, S.
    Masoum, M. A. S.
    IET RENEWABLE POWER GENERATION, 2011, 5 (05) : 368 - 376
  • [25] Influence of Different Series Dynamic Resistors on Low-voltage Ride-through of Brushless Doubly Fed Induction Generator
    Tohidi, Sajjad
    Oraee, Hashem
    Zolghadri, Mohammad Reza
    Tavner, Peter J.
    ELECTRIC POWER COMPONENTS AND SYSTEMS, 2015, 43 (8-10) : 995 - 1005
  • [26] Control strategy of doubly-fed induction generator during the grid voltage swell
    Zou Le
    Wu Xueguang
    Kou Longze
    Liu Dong
    Li Fangyuan
    Han Mingxiao
    JOURNAL OF ENGINEERING-JOE, 2019, (16): : 1807 - 1811
  • [27] IMC robust control for high-voltage ride-through of doubly fed induction wind generator
    Ma, Xiaoyang
    Yang, Honggeng
    IEEJ TRANSACTIONS ON ELECTRICAL AND ELECTRONIC ENGINEERING, 2018, 13 (09) : 1265 - 1275
  • [28] A Study of Doubly Fed Induction Generator's Low Voltage Ride Through Capabilities
    Altmayer, Kumud S.
    Iqbal, Kamran
    Wu, Charles
    2013 4TH IEEE INTERNATIONAL SYMPOSIUM ON POWER ELECTRONICS FOR DISTRIBUTED GENERATION SYSTEMS (PEDG), 2013,
  • [29] Doubly Fed Induction Generator Wind Farm Fault ride-through capability
    Hilal, Mohamed
    Errami, Youssef
    Benchagra, Mohamed
    Maaroufi, Mohamed
    Cherkaoui, Mohamed
    Ouassaid, Mohammed
    2012 INTERNATIONAL CONFERENCE ON MULTIMEDIA COMPUTING AND SYSTEMS (ICMCS), 2012, : 1079 - 1082
  • [30] Research on low voltage ride-through strategies for doubly-fed wind farms during asymmetric faults
    Li, Botong
    Zheng, Dingchuan
    Li, Bin
    Ji, Liang
    Hong, Qiteng
    Meng, Qinglin
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2024, 160