Current status of the use of inferior vena cava filters in cases of pulmonary embolism in CCUs: From the Tokyo CCU Network

被引:10
作者
Tanabe, Yasuhiro [1 ,2 ]
Obayashi, Toru [1 ]
Yamamoto, Takeshi [1 ]
Nakata, Jun [1 ]
Yagi, Hidenori [1 ]
Takayama, Morimasa [1 ]
Nagao, Ken [1 ]
机构
[1] Tokyo CCU Network Sci Comm, Tokyo, Japan
[2] Tokyo Metropolitan Hiroo Gen Hosp, Dept Cardiol, Tokyo 1500013, Japan
关键词
Pulmonary embolism; Deep vein thrombosis; Inferior vena cava filter; COMPLICATIONS;
D O I
10.1016/j.jjcc.2013.10.003
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: To elucidate the current status of use of inferior vena cava filters (IVCFs) in cases of pulmonary embolism at institutions belonging to the Tokyo CCU Network. Methods: We conducted a retrospective investigation of 832 consecutive cases of pulmonary embolism reported on survey forms to the Tokyo CCU Network between 2005 and 2010. Results: Of 832 cases of pulmonary embolism, IVCFs were used in 338(40.6%) and not used in 415(49.9%). Their use was unclear in 79(9.5%) cases. The use rate gradually increased each year from 2005 until 2008 but decreased from 2009 onward. Moreover, 68.9% of the IVCFs used in cases were non-permanent types. In terms of pulmonary embolism severity, the rate of use was 37.2% in non-massive cases, 49.4% in sub-massive cases, 46.9% in massive cases, and 31.9% in collapse cases. Thirty-day mortality in cases of collapse in which IVCFs were not used was extremely high at 75.8%, suggesting that in many cases, rapid deterioration may occur with insufficient time for IVCF insertion. The differences in IVCF usage rate among institutions were large in the range of 12.5-90% from 2005 to 2008, which slightly declined to the range of 25.0-72.2% from 2009 to 2010. Conclusions: We elucidated the current IVCF use status in cases of pulmonary embolism at institutions belonging to the Tokyo CCU Network. Since the status of use differed among institutions, future studies of effective methods of use are required. (c) 2013 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:385 / 389
页数:5
相关论文
共 18 条
[1]   Guidelines for the Diagnosis, Treatment and Prevention of Pulmonary Thromboembolism and Deep Vein Thrombosis (JCS 2009) - Digest Version [J].
Ando, Motomi ;
Fukuda, Ikuo ;
Ito, Masaaki ;
Kobayashi, Takao ;
Masuda, Masahisa ;
Miyahara, Yoshiyuki ;
Nakanishi, Norifumi ;
Niwa, Akihiro ;
Ohgi, Shigetsugu ;
Tajima, Hiroyuki ;
Ishibashi, Hiroyuki ;
Kanaoka, Yasushi ;
Nakamura, Mashio ;
Sakuma, Masahito ;
Satoh, Toru ;
Tanabe, Nobuhiro ;
Yamada, Norikazu ;
Yamashita, Mitsuru ;
Kuriyama, Takayuki ;
Matsubara, Junichi ;
Nakano, Takeshi ;
Ozaki, Yukio ;
Sakata, Ryuzo .
CIRCULATION JOURNAL, 2011, 75 (05) :1258-1281
[2]   Usefulness of cardiac biomarkers in the prediction of right ventricular dysfunction before echocardiography in acute pulmonary embolism [J].
Choi, Hong Sang ;
Kim, Kye Hun ;
Yoon, Hyun Ju ;
Hong, Young Joon ;
Kim, Ju Han ;
Ahn, Youngkeun ;
Jeong, Myung Ho ;
Cho, Jeong Gwan ;
Park, Jong Chun ;
Kang, Jung Chaee .
JOURNAL OF CARDIOLOGY, 2012, 60 (5-6) :508-513
[3]   A clinical trial of vena caval filters in the prevention of pulmonary embolism in patients with proximal deep-vein thrombosis [J].
Decousus, H ;
Leizorovicz, A ;
Parent, F ;
Page, Y ;
Tardy, B ;
Girard, P ;
Laporte, S ;
Faivre, R ;
Charbonnier, B ;
Barral, FG ;
Huet, Y ;
Simonneau, G .
NEW ENGLAND JOURNAL OF MEDICINE, 1998, 338 (07) :409-415
[4]  
Japanese Circulation Society, 2005, J Cardiol, V45, P349
[5]  
Kaufman JA, 2010, ENDOVASCULAR TOD FEB, P52
[6]   Massive pulmonary embolism [J].
Kucher, N ;
Rossi, E ;
De Rosa, M ;
Goldhaber, SZ .
CIRCULATION, 2006, 113 (04) :577-582
[7]   Predictive Value of the High-Sensitivity Troponin T Assay and the Simplified Pulmonary Embolism Severity Index in Hemodynamically Stable Patients With Acute Pulmonary Embolism A Prospective Validation Study [J].
Lankeit, Mareike ;
Jimenez, David ;
Kostrubiec, Maciej ;
Dellas, Claudia ;
Hasenfuss, Gerd ;
Pruszczyk, Piotr ;
Konstantinides, Stavros .
CIRCULATION, 2011, 124 (24) :2716-U300
[8]   Clinical characteristics of acute pulmonary thromboembolism in Japan: Results of a multicenter registry in the Japanese Society of Pulmonary Embolism Research [J].
Nakamura, M ;
Fujioka, H ;
Yamada, N ;
Sakuma, M ;
Okada, O ;
Nakanishi, N ;
Miyahara, Y ;
Kuriyama, T ;
Kunieda, T ;
Sugimoto, T ;
Nakano, T .
CLINICAL CARDIOLOGY, 2001, 24 (02) :132-138
[9]   Latest Management and Outcomes of Major Pulmonary Embolism in the Cardiovascular Disease Early Transport System: Tokyo CCU Network [J].
Obayashi, Tohru ;
Tanabe, Yasuhiro ;
Yagi, Hidenori ;
Yamamoto, Takeshi ;
Nagao, Ken ;
Sato, Naoki ;
Takayama, Morimasa .
CIRCULATION JOURNAL, 2010, 74 (02) :289-293
[10]   The Gunther-Tulip retrievable IVC filter - Clinical experience in 118 consecutive patients [J].
Ota, Satoshi ;
Yamada, Norikazu ;
Tsuji, Akihiro ;
Ishikura, Ken ;
Nakamura, Mashio ;
Isaka, Naoki ;
Ito, Masaaki .
CIRCULATION JOURNAL, 2008, 72 (02) :287-292