Hollow fiber liquid-phase microextraction of cadmium(II) using an ionic liquid as the extractant

被引:24
作者
Chen, Hui [1 ]
Han, Juan [2 ]
Wang, Yun [1 ]
Hu, Yutao [1 ]
Ni, Liang [1 ]
Liu, Yingying [1 ]
Kang, Wenbing [1 ]
Liu, Yan [1 ]
机构
[1] Jiangsu Univ, Sch Chem & Chem Engn, Zhenjiang 212013, Peoples R China
[2] Jiangsu Univ, Sch Food & Biol Engn, Zhenjiang 212013, Peoples R China
基金
中国国家自然科学基金; 中国博士后科学基金;
关键词
Hollow fiber liquid-phase microextraction; Ionic liquid; Graphite furnace atomic-absorption spectrometry; Cadmium; ATOMIC-ABSORPTION-SPECTROMETRY; CHROMATOGRAPHY-MASS SPECTROMETRY; CLOUD POINT EXTRACTION; WATER SAMPLES; MEMBRANE MICROEXTRACTION; SINGLE-DROP; PRECONCENTRATION; SEAWATER; LEAD;
D O I
10.1007/s00604-014-1274-x
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A method is presented for hollow fiber liquid-phase microextraction (HF-LPME) of cadmium(II), which is chelated with 1-(2-pyridylazo)-2-naphthol (PAN) to obtain a hydrophobic complex which then is extracted into a polypropylene hollow fiber containing an ionic liquid in its pores which acts as the membrane phase. EDTA is then injected into the lumen of the membrane as an acceptor phase to trap the analyte. The extraction time (20 min), agitation (400 rpm at 25 A degrees C), pH value (10.0), and the concentrations of PAN (2.5 ng mL(-1)) and EDTA (250 ng mL(-1)) were optimized. With a sample volume of 50 mL and a stripping volume of 15 mu L, the enrichment factor is 162. Cadmium(II) was then quantified by graphite furnace AAS. The limit of detection is 0.12 pg mL(-1), the relative standard deviation is 5.2 %, and the linear working range extends from 4 to 45 pg mL(-1). The method was successfully applied to the determination of Cd(II) in environmental and food samples.
引用
收藏
页码:1455 / 1461
页数:7
相关论文
共 27 条
[21]   Determination of Pb and Cd in water by potentiometric stripping analysis (PSA) [J].
Stankovic, Slavka ;
Cickaric, Dragana ;
Markovic, Jelena .
DESALINATION, 2007, 213 (1-3) :282-287
[22]   Hollow fiber supported ionic liquid membrane microextraction for determination of sulfonamides in environmental water samples by high-performance liquid chromatography [J].
Tao, Yong ;
Liu, Jing-Fu ;
Hu, Xia-Lin ;
Li, Hong-Cheng ;
Wang, Thanh ;
Jiang, Gui-Bin .
JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (35) :6259-6266
[23]   Liquid-liquid extraction of cadmium by sodium diethyldithiocarbamate from biological matrixes for isotope dilution inductively coupled plasma mass spectrometry [J].
Vanderpool, RA ;
Buckley, WT .
ANALYTICAL CHEMISTRY, 1999, 71 (03) :652-659
[24]   Ionic liquid-based hollow fiber supported liquid membrane extraction combined with thermospray flame furnace AAS for the determination of cadmium [J].
Zeng, Chujie ;
Hu, Yan ;
Luo, Jiwen .
MICROCHIMICA ACTA, 2012, 177 (1-2) :53-58
[25]   Hollow fiber supported liquid membrane extraction coupled with thermospray flame furnace atomic absorption spectrometry for the speciation of Sb(III) and Sb(V) in environmental and biological samples [J].
Zeng, Chujie ;
Yang, Fangwen ;
Zhou, Neng .
MICROCHEMICAL JOURNAL, 2011, 98 (02) :307-311
[26]   Preconcentration of nickel and cadmium by TiO2 nanotubes as solid-phase extraction adsorbents coupled with flame atomic absorption spectrometry [J].
Zhou, Qing-xiang ;
Zhao, Xin-ning ;
Xiao, Jun-ping .
TALANTA, 2009, 77 (05) :1774-1777
[27]   Determination of trace cadmium in water samples by graphite furnace atomic absorption spectrometry after cloud point extraction [J].
Zhu, XS ;
Zhu, XH ;
Wang, BS .
MICROCHIMICA ACTA, 2006, 154 (1-2) :95-100