Segmental motion adjacent to an instrumented lumbar fusion - The effect of extension of fusion to the sacrum

被引:35
作者
Untch, C [1 ]
Liu, Q [1 ]
Hart, R [1 ]
机构
[1] OHSU, Dept Orthopaed & Rehabil, Portland, OR 97201 USA
关键词
adjacent segment degeneration; fusion; lumbosacral; lumbar; biomechanics;
D O I
10.1097/01.brs.0000143667.55696.bd
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. We present an in vitro biomechanical comparison of adjacent segment motion at the cranial segment (L3-L4) for an L4-L5 versus an L4-S1 fusion model using cadaveric lumbosacral spines. Objectives. The purpose is to determine the biomechanical effect on the unfused cranial segment of extending a short lumbar fusion to the sacrum versus stopping at L5. Summary of Background Data. Radiographic evidence of adjacent segment degeneration can occur as a late sequela in patients following lumbar and lumbosacral spinal fusions. It is believed that altered biomechanics adjacent to the fusion construct contribute to these degenerative changes. Little is known regarding changes in cranial adjacent segment mechanics resulting from inclusion of the sacrum compared to ending a fusion at L5. Methods. Seven human cadaveric lumbosacral spines were instrumented with pedicle screws at L4, L5, and S1. Rods were placed from L4-L5 and from L4-S1 to simulate the corresponding fusion models. A material testing system was used to apply load-controlled moments to the spines in flexion-extension, lateral bending, and axial rotation. Electromagnetic sensors were used to record 6 df motion across the L3-L4, L4-L5, and L5-S1 motion segments. Angular displacements were recorded and system stiffness was calculated for each spine and construct. A paired sample t test was used to determine significance of recorded differences. Results. Under flexion-extension loading, the angular displacement in the sagittal plane at L3-L4 for the L4-S1 model was 9.0 compared to 7.8 for the L4-L5 model (+15%; P = 0.002). Under lateral bending loading, L3-L4 motion in the coronal plane for the L4-S1 model was 12.8 and was 14.5 for the L4-L5 model (-12%; P = 0.002). In axial rotation testing, L3-L4 torsional motion for the L4-S1 model was equivalent to the L4-L5 model. Overall system stiffness increased for the L4-S1 model compared with the L4-L5 model. Conclusions. In this load-controlled model, extending fusion across L5-S1 did not consistently increase motion at L3-L4. While it may be difficult to translate this finding to a clinical setting, avoiding fusion to the sacrum in a lower lumbar fusion may not provide significant benefit from the standpoint of avoiding adjacent segment disease.
引用
收藏
页码:2376 / 2381
页数:6
相关论文
共 50 条
  • [31] Biomechanical Evaluation of Transforaminal Lumbar Interbody Fusion and Oblique Lumbar Interbody Fusion on the Adjacent Segment: A Finite Element Analysis
    Wang, Bingjin
    Hua, Wenbin
    Ke, Wencan
    Lu, Saideng
    Li, Xingsheng
    Zeng, Xianlin
    Yang, Cao
    WORLD NEUROSURGERY, 2019, 126 : E819 - E824
  • [32] Evaluation of Outcome of Posterior Decompression and Instrumented Fusion in Lumbar and Lumbosacral Tuberculosis
    Jain, Akshay
    Jain, Ravikant
    Kiyawat, Vivek
    CLINICS IN ORTHOPEDIC SURGERY, 2016, 8 (03) : 268 - 273
  • [33] Percutaneous Vertebroplasty for Cephalad Vertebral Fractures After Instrumented Lumbar Fusion
    Seo, Jun-Yeong
    Ha, Kee-Yong
    Son, Il-Nam
    Chang, Dong-Gune
    Kim, Young-Hoon
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2013, 26 (02): : E58 - E64
  • [34] Adjacent Segment Disease After Instrumented Fusion for Idiopathic Scoliosis Review of Current Trends and Controversies
    Ilharreborde, Brice
    Morel, Etienne
    Mazda, Keyvan
    Dekutoski, Mark B.
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2009, 22 (07): : 530 - 539
  • [35] The Standing and Sitting Spino-Pelvic Sagittal Alignment in Patients with Instrumented Lumbar Fusion Might Correlate with Adjacent Segment Degeneration
    Zhou, Siyu
    Zhong, Woquan
    Sun, Zhuoran
    Guo, Yang
    Zhao, Yi
    Li, Wei
    Li, Weishi
    ORTHOPAEDIC SURGERY, 2022, 14 (12) : 3313 - 3321
  • [36] Kinetic magnetic resonance imaging analysis of lumbar segmental motion at levels adjacent to disc herniation
    Lao, Lifeng
    Daubs, Michael D.
    Takahashi, Shinji
    Lord, Elizabeth L.
    Cohen, Jeremiah R.
    Zhong, Guibin
    Wang, Jeffrey C.
    EUROPEAN SPINE JOURNAL, 2016, 25 (01) : 222 - 229
  • [37] The Efficacy of Lumbar Hybrid Fusion for the Prevention of Adjacent Segment Disease Fact or Artifact? A Meta-analysis
    Cho, Hyun-Jae
    Ko, Young San
    Won, Young Il
    Lee, Chang-Hyun
    Yang, Seung Heon
    Kim, Chi Heon
    Chung, Chun Kee
    CLINICAL SPINE SURGERY, 2021, 34 (07): : 260 - 268
  • [38] How Does Cage Lordosis Influence Postoperative Segmental Lordosis in Lumbar Interbody Fusion
    Gambhir, Shanu
    Wang, Tian
    Pelletier, Matthew H.
    Walsh, William R.
    Ball, Jonathon R.
    WORLD NEUROSURGERY, 2019, 126 : E606 - E611
  • [39] Stand-alone lateral lumbar interbody fusion for the treatment of symptomatic adjacent segment degeneration following previous lumbar fusion
    Louie, Philip K.
    Varthi, Arya G.
    Narain, Ankur S.
    Lei, Victor
    Bohl, Daniel D.
    Shifflett, Grant D.
    Phillips, Frank M.
    SPINE JOURNAL, 2018, 18 (11) : 2025 - 2032
  • [40] Biomechanical analysis of lateral interbody fusion strategies for adjacent segment degeneration in the lumbar spine
    Metzger, Melodie F.
    Robinson, Samuel T.
    Maldonado, Ruben C.
    Rawlinson, Jeremy
    Liu, John
    Acosta, Frank L.
    SPINE JOURNAL, 2017, 17 (07) : 1004 - 1011