Segmental motion adjacent to an instrumented lumbar fusion - The effect of extension of fusion to the sacrum

被引:35
作者
Untch, C [1 ]
Liu, Q [1 ]
Hart, R [1 ]
机构
[1] OHSU, Dept Orthopaed & Rehabil, Portland, OR 97201 USA
关键词
adjacent segment degeneration; fusion; lumbosacral; lumbar; biomechanics;
D O I
10.1097/01.brs.0000143667.55696.bd
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. We present an in vitro biomechanical comparison of adjacent segment motion at the cranial segment (L3-L4) for an L4-L5 versus an L4-S1 fusion model using cadaveric lumbosacral spines. Objectives. The purpose is to determine the biomechanical effect on the unfused cranial segment of extending a short lumbar fusion to the sacrum versus stopping at L5. Summary of Background Data. Radiographic evidence of adjacent segment degeneration can occur as a late sequela in patients following lumbar and lumbosacral spinal fusions. It is believed that altered biomechanics adjacent to the fusion construct contribute to these degenerative changes. Little is known regarding changes in cranial adjacent segment mechanics resulting from inclusion of the sacrum compared to ending a fusion at L5. Methods. Seven human cadaveric lumbosacral spines were instrumented with pedicle screws at L4, L5, and S1. Rods were placed from L4-L5 and from L4-S1 to simulate the corresponding fusion models. A material testing system was used to apply load-controlled moments to the spines in flexion-extension, lateral bending, and axial rotation. Electromagnetic sensors were used to record 6 df motion across the L3-L4, L4-L5, and L5-S1 motion segments. Angular displacements were recorded and system stiffness was calculated for each spine and construct. A paired sample t test was used to determine significance of recorded differences. Results. Under flexion-extension loading, the angular displacement in the sagittal plane at L3-L4 for the L4-S1 model was 9.0 compared to 7.8 for the L4-L5 model (+15%; P = 0.002). Under lateral bending loading, L3-L4 motion in the coronal plane for the L4-S1 model was 12.8 and was 14.5 for the L4-L5 model (-12%; P = 0.002). In axial rotation testing, L3-L4 torsional motion for the L4-S1 model was equivalent to the L4-L5 model. Overall system stiffness increased for the L4-S1 model compared with the L4-L5 model. Conclusions. In this load-controlled model, extending fusion across L5-S1 did not consistently increase motion at L3-L4. While it may be difficult to translate this finding to a clinical setting, avoiding fusion to the sacrum in a lower lumbar fusion may not provide significant benefit from the standpoint of avoiding adjacent segment disease.
引用
收藏
页码:2376 / 2381
页数:6
相关论文
共 50 条
  • [21] Extension of Spine Fusion to the Sacrum Following Long Fusions for Deformity Correction
    O'Neill, Kevin R.
    Bridwell, Keith H.
    Lenke, Lawrence G.
    Chuntarapas, Tapanut
    Dorward, Ian
    Neuman, Brian
    Ahmad, Azeem
    Baldus, Christine
    SPINE, 2014, 39 (12) : 953 - 962
  • [22] Factors Predictive of Adjacent Segment Disease After Lumbar Spinal Fusion
    Maragkos, Georgios A.
    Motiei-Langroudi, Rouzbeh
    Filippidis, Aristotelis S.
    Glazer, Paul A.
    Papavassiliou, Efstathios
    WORLD NEUROSURGERY, 2020, 133 : E690 - E694
  • [23] OPERATIVE TREATMENT OF THE DEGENERATED SEGMENT ADJACENT TO A LUMBAR FUSION
    WHITECLOUD, TS
    DAVIS, JM
    OLIVE, PM
    SPINE, 1994, 19 (05) : 531 - 536
  • [24] Adjacent segment motion after a simulated lumbar fusion in different sagittal alignments - A biomechanical analysis
    Akamaru, T
    Kawahara, N
    Yoon, ST
    Minamide, A
    Kim, KS
    Tomita, K
    Hutton, WC
    SPINE, 2003, 28 (14) : 1560 - 1566
  • [25] Determining a relative total lumbar range of motion to alleviate adjacent segment degeneration after transforaminal lumbar interbody fusion: a finite element analysis
    Li, Ke
    Cao, Shuai
    Chen, Jing
    Qin, Jie
    Yuan, Bo
    Li, Jie
    BMC MUSCULOSKELETAL DISORDERS, 2024, 25 (01)
  • [26] Adjacent segment degeneration and disease after lumbar fusion compared with motion-preserving procedures: a meta-analysis
    Ren C.
    Song Y.
    Liu L.
    Xue Y.
    European Journal of Orthopaedic Surgery & Traumatology, 2014, 24 (Suppl 1) : 245 - 253
  • [27] Adjacent segment degeneration after instrumented posterolateral lumbar fusion: a prospective cohort study with a minimum five-year follow-up
    Anandjiwala, Jigar
    Seo, Jun-Yeong
    Ha, Kee-Yong
    Oh, In-Soo
    Shin, Dong-Cheul
    EUROPEAN SPINE JOURNAL, 2011, 20 (11) : 1951 - 1960
  • [28] Instrumented transforaminal lumbar interbody fusion with bioresorbable polymer implants and iliac crest autograft
    Coe, JD
    Vaccaro, AR
    SPINE, 2005, 30 (17) : S76 - S83
  • [29] Comparison of mechanical motion profiles following instrumented fusion and non-instrumented fusion at the L4-5 segment
    Kim, Ho-Joong
    Moon, Seong-Hwan
    Chun, Heoung-Jae
    Kang, Kyoung-Tak
    Kim, Hak-Sun
    Moon, Eun-Su
    Park, Jin-Oh
    Hwang, Byung-Yoon
    Lee, Hwan-Mo
    CLINICAL AND INVESTIGATIVE MEDICINE, 2009, 32 (01): : E64 - E69
  • [30] Adjacent-segment degeneration after lumbar fusion with instrumentation: A retrospective study
    Rahm, MD
    Hall, BB
    JOURNAL OF SPINAL DISORDERS, 1996, 9 (05): : 392 - 400