Segmental motion adjacent to an instrumented lumbar fusion - The effect of extension of fusion to the sacrum

被引:35
作者
Untch, C [1 ]
Liu, Q [1 ]
Hart, R [1 ]
机构
[1] OHSU, Dept Orthopaed & Rehabil, Portland, OR 97201 USA
关键词
adjacent segment degeneration; fusion; lumbosacral; lumbar; biomechanics;
D O I
10.1097/01.brs.0000143667.55696.bd
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. We present an in vitro biomechanical comparison of adjacent segment motion at the cranial segment (L3-L4) for an L4-L5 versus an L4-S1 fusion model using cadaveric lumbosacral spines. Objectives. The purpose is to determine the biomechanical effect on the unfused cranial segment of extending a short lumbar fusion to the sacrum versus stopping at L5. Summary of Background Data. Radiographic evidence of adjacent segment degeneration can occur as a late sequela in patients following lumbar and lumbosacral spinal fusions. It is believed that altered biomechanics adjacent to the fusion construct contribute to these degenerative changes. Little is known regarding changes in cranial adjacent segment mechanics resulting from inclusion of the sacrum compared to ending a fusion at L5. Methods. Seven human cadaveric lumbosacral spines were instrumented with pedicle screws at L4, L5, and S1. Rods were placed from L4-L5 and from L4-S1 to simulate the corresponding fusion models. A material testing system was used to apply load-controlled moments to the spines in flexion-extension, lateral bending, and axial rotation. Electromagnetic sensors were used to record 6 df motion across the L3-L4, L4-L5, and L5-S1 motion segments. Angular displacements were recorded and system stiffness was calculated for each spine and construct. A paired sample t test was used to determine significance of recorded differences. Results. Under flexion-extension loading, the angular displacement in the sagittal plane at L3-L4 for the L4-S1 model was 9.0 compared to 7.8 for the L4-L5 model (+15%; P = 0.002). Under lateral bending loading, L3-L4 motion in the coronal plane for the L4-S1 model was 12.8 and was 14.5 for the L4-L5 model (-12%; P = 0.002). In axial rotation testing, L3-L4 torsional motion for the L4-S1 model was equivalent to the L4-L5 model. Overall system stiffness increased for the L4-S1 model compared with the L4-L5 model. Conclusions. In this load-controlled model, extending fusion across L5-S1 did not consistently increase motion at L3-L4. While it may be difficult to translate this finding to a clinical setting, avoiding fusion to the sacrum in a lower lumbar fusion may not provide significant benefit from the standpoint of avoiding adjacent segment disease.
引用
收藏
页码:2376 / 2381
页数:6
相关论文
共 50 条
  • [1] The biomechanical effect of postoperative hypolordosis in instrumented lumbar fusion on instrumented and adjacent spinal segments
    Umehara, S
    Zindrick, MR
    Patwardhan, AG
    Havey, RM
    Vrbos, LA
    Knight, GW
    Miyano, S
    Kirincic, M
    Kaneda, K
    Lorenz, MA
    SPINE, 2000, 25 (13) : 1617 - 1624
  • [2] Lumbar Fusion in Achondroplasia Does Fusion to the Sacrum Affect Function?
    Farmer, Kevin W.
    Brinkley, Michael F.
    Skolasky, Richard L.
    Sponseller, Paul D.
    Ain, Michael C.
    JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2009, 29 (05) : 476 - 480
  • [3] The clinical characteristics and risk factors for the adjacent segment degeneration in instrumented lumbar fusion
    Min, Jun-Hong
    Jang, Jee-Soo
    Jung, Byungjoo
    Lee, Ho Yeon
    Choi, Won-Chul
    Shim, Chan Shik
    Choi, Gun
    Lee, Sang-Ho
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2008, 21 (05): : 305 - 309
  • [4] Biomechanical study on the effect of cervical spine fusion on adjacent-level intradiscal pressure and segmental motion
    Eck, JC
    Humphreys, SC
    Lim, TH
    Jeong, ST
    Kim, JG
    Hodges, SD
    An, HS
    SPINE, 2002, 27 (22) : 2431 - 2434
  • [5] Outcomes of Instrumented and Noninstrumented Posterolateral Lumbar Fusion
    Pourtaheri, Sina
    Billings, Charles
    Bogatch, Michael
    Issa, Kimona
    Haraszti, Christopher
    Mangel, Daniel
    Lord, Elizabeth
    Park, Howard
    Ajiboye, Remi
    Ashana, Adedayo
    Emami, Arash
    ORTHOPEDICS, 2015, 38 (12) : E1104 - E1109
  • [6] Adjacent segment disease after instrumented fusion for adult lumbar spondylolisthesis: Incidence and risk factors
    Zhong, Zhao-Ming
    Deviren, Vedat
    Tay, Bobby
    Burch, Shane
    Berven, Sigurd H.
    CLINICAL NEUROLOGY AND NEUROSURGERY, 2017, 156 : 29 - 34
  • [7] Sacroiliac Joint Fusion Minimally Affects Adjacent Lumbar Segment Motion: A Finite Element Study
    Lindsey, Derek P.
    Kiapour, Ali
    Yerby, Scott A.
    Goel, Vijay K.
    INTERNATIONAL JOURNAL OF SPINE SURGERY, 2015, 9
  • [8] Considerations for Lumbar Medial Branch Nerve Radiofrequency at Spinal Motion Segments Adjacent to a Fusion Construct
    Turtle, Joel
    Miller, Scott
    Yang, Aaron
    Hurley, Robert W.
    Spina, Nicholas
    McCormick, Zachary L.
    PAIN MEDICINE, 2023, 24 (02) : 165 - 170
  • [9] Do PEEK Rods for Posterior Instrumented Fusion in the Lumbar Spine Reduce the Risk of Adjacent Segment Disease?
    Hirt, Daniel
    Prentice, Heather A.
    Harris, Jessica E.
    Paxton, Elizabeth W.
    Alexander, Jessa
    Nagasawa, Daniel T.
    Khosla, Deven
    Kurtz, Steven M.
    INTERNATIONAL JOURNAL OF SPINE SURGERY, 2021, 15 (02) : 251 - 258
  • [10] Effect of segmental lordosis on early-onset adjacent-segment disease after posterior lumbar interbody fusion
    Okuda, Shinya
    Nagamoto, Yukitaka
    Takenaka, Shota
    Ikuta, Masato
    Matsumoto, Tomiya
    Takahashi, Yoshifumi
    Furuya, Masayuki
    Iwasaki, Motoki
    JOURNAL OF NEUROSURGERY-SPINE, 2021, 35 (04) : 454 - 459