Functional assessment of intermediate coronary artery stenosis with 4-Fr catheters

被引:1
作者
Nogi, Kazutaka [1 ,2 ]
Soeda, Tsunenari [1 ]
Hara, Masahiko [3 ]
Iwama, Hajime [2 ]
Toyokawa, Nozomi [2 ]
Sakai, Satoshi [2 ]
Yano, Hiroki [1 ,2 ]
Iwai, Atsushi [2 ]
Hashimoto, Yukihiro [1 ,2 ]
Fujimoto, Hajime [2 ]
Suzuki, Megumi [2 ]
Nakai, Takehito [2 ]
Doi, Naofumi [2 ]
Saito, Yoshihiko [1 ]
机构
[1] Nara Med Univ, Dept Cardiovasc Med, 840 Shijo Cho, Kashihara, Nara 6348522, Japan
[2] Nara Prefecture Seiwa Med Ctr, Dept Cardiovasc Med, Sango, Japan
[3] Shimane Univ, Ctr Community Based Healthcare Res & Educ, Izumo, Shimane, Japan
关键词
Coronary artery disease; Functional coronary assessment; Pd; pa; Instantaneous wave-free ratio; Fractional flow reserve; FRACTIONAL FLOW RESERVE; 4; FRENCH; ACCURACY;
D O I
10.1007/s00380-020-01746-2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The 4-Fr catheter system is not recommended for invasive functional assessment of coronary artery stenosis, because it tends to distort the aortic waveform. This study aimed to identify the incidence of aortic waveform distortion and a feasible method for correct diagnosis of coronary artery stenosis with a 4-Fr catheter. We retrospectively investigated 178 lesions with intermediate coronary artery stenosis. Non-hyperemic distal coronary artery pressure (Pd) and aortic pressure (Pa) were measured with a 4-Fr diagnostic or 6-Fr guiding catheter before and after saline flush. The mean Pd/mean Pa (Pd/Pa) and instantaneous wave-free ratio (iFR) were calculated before and after flushing. We compared the effect of flushing on the changes in Pd/Pa and iFR between the 4-Fr diagnostic and 6-Fr guiding catheters. Using the 4-Fr diagnostic catheter, there was a significant decrease in incidence of aortic waveform distortion from 42.0% (47 lesions) before flushing to 1.8% (2 lesions) after flushing (p < 0.001); the incidence was only 3.0% before saline flush and decreased to 0% after saline flush when using the 6-Fr guiding catheter. The presence of aortic waveform distortion influenced the iFR when the 4-Fr system was used. Functional measurements with the 4-Fr diagnostic catheter require adequate saline flush to remove the influence of aortic waveform distortion.
引用
收藏
页码:638 / 645
页数:8
相关论文
共 17 条
  • [1] Fractional Flow Reserve-Guided PCI versus Medical Therapy in Stable Coronary Disease
    De Bruyne, Bernard
    Pijls, Nico H. J.
    Kalesan, Bindu
    Barbato, Emanuele
    Tonino, Pim A. L.
    Piroth, Zsolt
    Jagic, Nikola
    Mobius-Winckler, Sven
    Rioufol, Gilles
    Witt, Nils
    Kala, Petr
    MacCarthy, Philip
    Engstrom, Thomas
    Oldroyd, Keith G.
    Mavromatis, Kreton
    Manoharan, Ganesh
    Verlee, Peter
    Frobert, Ole
    Curzen, Nick
    Johnson, Jane B.
    Jueni, Peter
    Fearon, William F.
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2012, 367 (11) : 991 - 1001
  • [2] Radial Versus Femoral Access for Coronary Interventions Across the Entire Spectrum of Patients With Coronary Artery Disease A Meta-Analysis of Randomized Trials
    Ferrante, Giuseppe
    Rao, Sunil V.
    Juni, Peter
    Da Costa, Bruno R.
    Reimers, Bernhard
    Condorelli, Gianluigi
    Anzuini, Angelo
    Jolly, Sanjit S.
    Bertrand, Olivier F.
    Krucoff, Mitchell W.
    Windecker, Stephan
    Valgimigli, Marco
    [J]. JACC-CARDIOVASCULAR INTERVENTIONS, 2016, 9 (14) : 1419 - 1434
  • [3] Interrelationship in the prognostic efficacy of regional coronary flow reserve, fractional flow reserve, high-sensitivity cardiac troponin-I and NT-proBNP in patients with stable coronary artery disease
    Hamaya, Rikuta
    Yonetsu, Taishi
    Kanaji, Yoshihisa
    Usui, Eisuke
    Hoshino, Masahiro
    Hada, Masahiro
    Kanno, Yoshinori
    Murai, Tadashi
    Lee, Tetsumin
    Kakuta, Tsunekazu
    [J]. HEART AND VESSELS, 2019, 34 (03) : 410 - 418
  • [4] A Test in Context Fractional Flow Reserve: Accuracy, Prognostic Implications, and Limitations
    Jeremias, Allen
    Kirtane, Ajay J.
    Stone, Gregg W.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 69 (22) : 2748 - 2758
  • [5] Feasibility and safety of intracoronary nicorandil infusion as a novel hyperemic agent for fractional flow reserve measurements
    Kato, Daiki
    Takashima, Hiroaki
    Waseda, Katsuhisa
    Kurita, Akiyoshi
    Kuroda, Yasuo
    Kosaka, Takashi
    Kuhara, Yasushi
    Ando, Hirohiko
    Maeda, Kazuyuki
    Kumagai, Soichiro
    Sakurai, Shinichiro
    Suzuki, Akihiro
    Toda, Yukiko
    Watanabe, Atsushi
    Sato, Shigeko
    Fujimoto, Masanobu
    Mizuno, Tomofumi
    Amano, Tetsuya
    [J]. HEART AND VESSELS, 2015, 30 (04) : 477 - 483
  • [6] Clinical use of physiological lesion assessment using pressure guidewires: an expert consensus document of the Japanese Association of Cardiovascular Intervention and Therapeutics
    Kawase, Yoshiaki
    Matsuo, Hitoshi
    Akasaka, Takashi
    Shiono, Yasutsugu
    Tanaka, Nobuhiro
    Amano, Tetsuya
    Kozuma, Ken
    Nakamura, Masato
    Yokoi, Hiroyoshi
    Kobayashi, Yoshio
    Ikari, Yuji
    [J]. CARDIOVASCULAR INTERVENTION AND THERAPEUTICS, 2019, 34 (01) : 85 - 96
  • [7] Trans-radial percutaneous coronary intervention for patients with severe chronic renal insufficiency and/or on dialysis
    Kuno, Toshiki
    Hirano, Keita
    Abe, Takayuki
    Imaeda, Shohei
    Hashimoto, Kenji
    Ryuzaki, Toshinobu
    Yokokura, Souichi
    Saito, Tetsuya
    Yamazaki, Hiroyuki
    Tabei, Ryota
    Kodaira, Masaki
    Numasawa, Yohei
    [J]. HEART AND VESSELS, 2019, 34 (09) : 1412 - 1419
  • [8] Measuring pressure-derived fractional flow reserve through four French diagnostic catheters
    Legalery, P
    Seronde, MF
    Meneveau, N
    Schiele, F
    Bassand, JP
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2003, 91 (09) : 1075 - 1078
  • [9] Accuracy of Fractional Flow Reserve Measurements in Clinical Practice Observations From a Core Laboratory Analysis
    Matsumura, Mitsuaki
    Johnson, Nils P.
    Fearon, William F.
    Mintz, Gary S.
    Stone, Gregg W.
    Oldroyd, Keith G.
    De Bruyne, Bernard
    Pijls, Nico H. J.
    Maehara, Akiko
    Jeremias, Allen
    [J]. JACC-CARDIOVASCULAR INTERVENTIONS, 2017, 10 (14) : 1392 - 1401
  • [10] McGhee B.H., 2002, Crit. Care. Nurse, V22, P60, DOI [DOI 10.4037/CCN2002.22.2.60, DOI 10.4037/ccn2002.22.2.60]