Circulating tumor-cell detection and capture using microfluidic devices

被引:108
作者
Hajba, Laszlo [1 ]
Guttman, Andras [1 ,2 ]
机构
[1] Univ Pannonia, MTA PE Translat Glyc, MUKKI, Veszprem, Hungary
[2] Univ Debrecen, Horvath Lab Bioseparat Sci, H-4012 Debrecen, Hungary
关键词
Cancer-therapy management; Circulating tumor cell (CTC); CTC capture; CTC detection; Dielectrophoresis; Early detection; Hydrodynamics; Metastases; Microfluidics; Nanotechnology; CANCER-PATIENTS; ON-CHIP; CONTINUOUS SEPARATION; MICROCAVITY ARRAY; BLOOD; SIZE; PARTICLES; DIELECTROPHORESIS; ELECTROMAGNETS; ENRICHMENT;
D O I
10.1016/j.trac.2014.02.017
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Circulating tumor cells (CTCs) in the bloodstream are considered good indicators of the presence of a primary tumor or even metastases. CTC capture has great importance in early detection of cancer, especially in identifying novel therapeutic routes for cancer patients by finding personalized druggable targets for the pharmaceutical industry. Recent developments in microfluidics and nanotechnology improved the capabilities of CTC detection and capture, including purity, selectivity and throughput. This article covers the recent technological improvements in microfluidics-based CTC-capture methods utilizing the physical and biochemical properties of CTCs. We critically review the most promising hydrodynamic, dielectrophoretic and magnetic force-based microfluidic CTC-capture devices. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:9 / 16
页数:8
相关论文
共 77 条
[1]   Interdigitated comb-like electrodes for continuous separation of malignant cells from blood using dielectrophoresis [J].
Alazzam, Anas ;
Stiharu, Ion ;
Bhat, Rama ;
Meguerditchian, Ari-Nareg .
ELECTROPHORESIS, 2011, 32 (11) :1327-1336
[2]   Circulating Tumor Cells and Circulating Tumor DNA [J].
Alix-Panabieres, Catherine ;
Schwarzenbach, Heidi ;
Pantel, Klaus .
ANNUAL REVIEW OF MEDICINE, VOL 63, 2012, 63 :199-215
[3]  
Bhagat A.A.S.H., 2011, DEAN FLOW FIELD FRAC, P524
[4]   Continuous particle separation in spiral microchannels using dean flows and differential migration [J].
Bhagat, Ali Asgar S. ;
Kuntaegowdanahalli, Sathyakumar S. ;
Papautsky, Ian .
LAB ON A CHIP, 2008, 8 (11) :1906-1914
[5]   Circulating tumor cells in non-small cell lung carcinoma [J].
Boshuizen, Rogier ;
Kuhn, Peter ;
van den Heuvel, Michel .
JOURNAL OF THORACIC DISEASE, 2012, 4 (05) :456-458
[6]   Estimation of Joule heating effect on temperature and pressure distribution in electrokinetic-driven microchannel flows [J].
Chein, RY ;
Yang, YC ;
Lin, YS .
ELECTROPHORESIS, 2006, 27 (03) :640-649
[7]   An on-chip magnetic bead separator using spiral electromagnets with semi-encapsulated permalloy [J].
Choi, JW ;
Liakopoulos, TM ;
Ahn, CH .
BIOSENSORS & BIOELECTRONICS, 2001, 16 (06) :409-416
[8]  
Cristofanilli M, 2004, NEW ENGL J MED, V351, P2453
[9]   Continuous inertial focusing, ordering, and separation of particles in microchannels [J].
Di Carlo, Dino ;
Irimia, Daniel ;
Tompkins, Ronald G. ;
Toner, Mehmet .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2007, 104 (48) :18892-18897
[10]   Inertial microfluidics [J].
Di Carlo, Dino .
LAB ON A CHIP, 2009, 9 (21) :3038-3046