Automated Analysis of Clozapine and Norclozapine in Human Plasma Using Novel Extraction Plate Technology and Flow-Injection Tandem Mass Spectrometry

被引:10
作者
Couchman, Lewis [1 ]
Subramaniam, Krithika [1 ]
Fisher, Danielle S. [1 ]
Belsey, Sarah L. [1 ]
Handley, Simon A. [1 ]
Flanagan, Robert J. [1 ]
机构
[1] Kings Coll Hosp NHS Fdn Trust, Dept Clin Biochem, Toxicol Unit, Viapath Analyt, London, England
关键词
clozapine; norclozapine; automated extraction; AC Extraction Plate; flow-injection analysis; PERFORMANCE LIQUID-CHROMATOGRAPHY; HEMOLYZED WHOLE-BLOOD; ATYPICAL ANTIPSYCHOTICS; ORAL FLUID; LC-MS/MS; SERUM;
D O I
10.1097/FTD.0000000000000231
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background:Analysis of plasma clozapine and N-desmethylclozapine (norclozapine) for therapeutic drug monitoring purposes is well established. To minimize analysis times and facilitate rapid reporting of results, we have fully automated sample preparation using novel AC Extraction Plates and a Tecan Freedom EVO 100 liquid handling platform, and minimized extract analysis times using flow-injection tandem mass spectrometry (FIA-MS/MS).Methods:Analytes and deuterium-labeled internal standards were extracted from plasma (100 L) at pH 10.6 and extracts analyzed directly using tandem mass spectrometry [20 L injection, 0.7 mL/min methanol carrier flow, analysis time (injection-to-injection) approximately 60 seconds].Results:Validation data showed excellent intraplate and interplate accuracy (95%-104% nominal concentrations). Interbatch precision (% RSD) at the limit of quantitation (0.01 mg/L) was 3.5% and 5.5% for clozapine and norclozapine, respectively. Matrix effects were observed for both clozapine and norclozapine, but were compensated for by the internal standards. Overall process efficiency was 56%-70% and 66%-77% for clozapine and norclozapine, respectively. Mean relative process efficiency was 98% and 99% for clozapine and norclozapine, respectively. Comparison of results from patient samples (n = 81) analyzed using (1) manual liquid-liquid extraction with liquid chromatography-tandem mass spectrometry (LC-MS/MS) and (2) automated extraction with FIA-MS/MS gave y = 1.01x - 0.002, R-2 = 0.9943 and y = 1.01x + 0.009, R-2 = 0.9957 for clozapine and norclozapine, respectively. Bland-Altman plots revealed a [mean (95% limits of agreement) bias of 0.0074 (-0.04 to 0.06) mg/L and of 0.015 (-0.02 to 0.05) mg/L for clozapine and norclozapine, respectively].Conclusions:FIA-MS/MS used with automated extraction offers a rapid, simple, cost-effective alternative to manual liquid-liquid extraction and conventional LC analysis for clozapine therapeutic drug monitoring.
引用
收藏
页码:42 / 49
页数:8
相关论文
共 16 条
[1]  
Bonfiglio R, 1999, RAPID COMMUN MASS SP, V13, P1175, DOI 10.1002/(SICI)1097-0231(19990630)13:12<1175::AID-RCM639>3.0.CO
[2]  
2-0
[3]  
Cooper DP, INTERNAL CALIBRATION
[4]   A novel approach to quantitative LC-MS/MS: therapeutic drug monitoring of clozapine and norclozapine using isotopic internal calibration [J].
Couchman, Lewis ;
Belsey, Sarah L. ;
Handley, Simon A. ;
Flanagan, Robert J. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2013, 405 (29) :9455-9466
[5]   LC-MS in analytical toxicology: some practical considerations [J].
Couchman, Lewis ;
Morgan, Phillip E. .
BIOMEDICAL CHROMATOGRAPHY, 2011, 25 (1-2) :100-123
[6]   Plasma Clozapine, Norclozapine, and the Clozapine: Norclozapine Ratio in Relation to Prescribed Dose and Other Factors: Data From a Therapeutic Drug Monitoring Service, 1993-2007 [J].
Couchman, Lewis ;
Morgan, Phillip Edgar ;
Spencer, Edgar Pathrose ;
Flanagan, Robert James .
THERAPEUTIC DRUG MONITORING, 2010, 32 (04) :438-447
[7]   Stability of some atypical antipsychotics in human plasma, haemolysed whole blood, oral fluid, human serum and calf serum [J].
Fisher, Danielle S. ;
Partridge, Suzanne J. ;
Handley, Simon A. ;
Flanagan, Robert J. .
FORENSIC SCIENCE INTERNATIONAL, 2013, 229 (1-3) :151-156
[8]   LC-MS/MS of some atypical antipsychotics in human plasma, serum, oral fluid and haemolysed whole blood [J].
Fisher, Danielle S. ;
Partridge, Suzanne J. ;
Handley, Simon A. ;
Couchman, Lewis ;
Morgan, Phillip E. ;
Flanagan, Robert J. .
FORENSIC SCIENCE INTERNATIONAL, 2013, 229 (1-3) :145-150
[9]  
Hiemke C, 2011, PHARMACOPSYCHIATRY, V44, P195, DOI 10.1055/s-0031-1286287
[10]   Strategies for the assessment of matrix effect in quantitative bioanalytical methods based on HPLC-MS/MS [J].
Matuszewski, BK ;
Constanzer, ML ;
Chavez-Eng, CM .
ANALYTICAL CHEMISTRY, 2003, 75 (13) :3019-3030