Deep inspiration breath-hold for left-sided breast irradiation: Analysis of dose-mass histograms and the impact of lung expansion

被引:36
作者
Oechsner, Markus [1 ]
Duesberg, Mathias [1 ]
Borm, Kai Joachim [1 ,2 ]
Combs, Stephanie Elisabeth [1 ,3 ]
Wilkens, Jan Jakob [1 ]
Duma, Marciana Nona [1 ,4 ]
机构
[1] Tech Univ Munich, Klinikum Rechts Isar, Sch Med, Dept Radiat Oncol, Ismaninger Str 22, D-81675 Munich, Germany
[2] Helmholtz Zentrum Munchen, Inst Innovat Radiotherapy iRT, Oberschleissheim, Germany
[3] Deutsch Konsortium Translat Krebsforsch DKTK, Partner Site Munich, Munich, Germany
[4] Univ Klinikum Jena, Dept Radiotherapy & Radiat Oncol, Jena, Germany
关键词
Breast cancer; Deep inspiration breath-hold; Gating; Heart dose; Lung dose; Dose-mass histogram; RADIATION-THERAPY; ADAPTED RADIOTHERAPY; CANCER; HEART; VOLUME; REDUCTION; WOMEN; RISK; PNEUMONITIS; DEFINITION;
D O I
10.1186/s13014-019-1293-1
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
BackgroundThe aim of this study was to compare dose-volume histogram (DVH) with dose-mass histogram (DMH) parameters for treatment of left-sided breast cancer in deep inspiration breath-hold (DIBH) and free breathing (FB). Additionally, lung expansion and anatomical factors were analyzed and correlated to dose differences.MethodsFor 31 patients 3D conformal radiation therapy plans were retrospectively calculated on FB and DIBH CTs in the treatment planning system. The calculated doses, structures and CT data were transferred into MATLAB and DVHs and DMHs were calculated. Mean doses (Dmean), volumes and masses receiving certain doses (Vx, Mx) were determined for the left lung and the heart. Additionally, expansion of the left lung was evaluated using deformable image registration. Differences in DVH and DMH dose parameters between FB and DIBH were statistically analyzed and correlated to lung expansion and anatomical factors.ResultsDIBH reduced Dmean (DVH) and relative V20 (V20 [%]) of the left lung in all patients, on average by -199% (mean +/- standard deviation) and-24 +/- 10%. Dmean (DMH) and M20 [%] were also significantly reduced (-12 +/- 11%, -16 +/- 13%), however 4 patients had higher DMH values in DIBH than in FB. Linear regression showed good correlations between DVH and DMH parameters, e.g. a dosimetric benefit smaller than 8.4% for Dmean (DVH) in DIBH indicated more irradiated lung mass in DIBH than in FB. The mean expansion of the left lung between FB and DIBH was 1.5 +/- 2.4mm (left), 16.0 +/- 4.0mm (anterior) and 12.2 +/- 4.6mm (caudal). No significant correlations were found between expansions and differences in Dmean for the left lung. The heart dose in DIBH was reduced in all patients by 53% (Dmean) and this dosimetric benefit correlated to lung expansion in anterior.Conclusions Treatment of left-sided breast cancer in DIBH reduced dose to the heart and in most cases the lung dose, relative irradiated lung volume and lung mass. A mass related dosimetric benefit in DIBH can be achieved as long as the volume related benefit is about 8-9%. The lung expansion (breathing pattern) showed no impact on lung dose, but on heart dose. A stronger chest breathing (anterior expansion) for DIBH seems to be more beneficial than abdominal breathing.
引用
收藏
页数:10
相关论文
共 39 条
[1]  
Abe O, 2005, LANCET, V365, P1687, DOI 10.1016/s0140-6736(05)66544-0
[2]   Deep-Inspiration Breath-Hold Radiation Therapy in Breast Cancer: A Word of Caution on the Dose to the Axillary Lymph Node Levels [J].
Borm, Kai Joachim ;
Oechsner, Markus ;
Combs, Stephanie E. ;
Duma, Marciana-Nona .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2018, 100 (01) :263-269
[3]   Dosimetric validation of Acuros® XB with Monte Carlo methods for photon dose calculations [J].
Bush, K. ;
Gagne, I. M. ;
Zavgorodni, S. ;
Ansbacher, W. ;
Beckham, W. .
MEDICAL PHYSICS, 2011, 38 (04) :2208-2221
[4]  
Butler Laura E, 2004, J Appl Clin Med Phys, V5, P16, DOI 10.1120/jacmp.26.146
[5]  
Czeremszynska B, 2017, REP PRACT ONCOL RADI, V22, P341, DOI 10.1016/j.rpor.2017.05.002
[6]   Risk of Ischemic Heart Disease in Women after Radiotherapy for Breast Cancer [J].
Darby, Sarah C. ;
Ewertz, Marianne ;
McGale, Paul ;
Bennet, Anna M. ;
Blom-Goldman, Ulla ;
Bronnum, Dorthe ;
Correa, Candace ;
Cutter, David ;
Gagliardi, Giovanna ;
Gigante, Bruna ;
Jensen, Maj-Britt ;
Nisbet, Andrew ;
Peto, Richard ;
Rahimi, Kazem ;
Taylor, Carolyn ;
Hall, Per .
NEW ENGLAND JOURNAL OF MEDICINE, 2013, 368 (11) :987-998
[7]   Effect of radiotherapy after breast-conserving surgery on 10-year recurrence and 15-year breast cancer death: meta-analysis of individual patient data for 10 801 women in 17 randomised trials [J].
Darby S. ;
McGale P. ;
Correa C. ;
Taylor C. ;
Arriagada R. ;
Clarke M. ;
Cutter D. ;
Davies C. ;
Ewertz M. ;
Godwin J. ;
Gray R. ;
Pierce L. ;
Whelan T. ;
Wang Y. ;
Peto R. ;
Albain K. ;
Anderson S. ;
Barlow W. ;
Bergh J. ;
Bliss J. ;
Buyse M. ;
Cameron D. ;
Carrasco E. ;
Coates A. ;
Collins R. ;
Costantino J. ;
Cuzick J. ;
Davidson N. ;
Davies K. ;
Delmestri A. ;
Di Leo A. ;
Dowsett M. ;
Elphinstone P. ;
Evans V. ;
Gelber R. ;
Gettins L. ;
Geyer C. ;
Goldhirsch A. ;
Gregory C. ;
Hayes D. ;
Hill C. ;
Ingle J. ;
Jakesz R. ;
James S. ;
Kaufmann M. ;
Kerr A. ;
MacKinnon E. ;
McHugh T. ;
Norton L. ;
Ohashi Y. .
LANCET, 2011, 378 (9804) :1707-1716
[8]   The impact of photon dose calculation algorithms on expected dose distributions in lungs under different respiratory phases [J].
Fogliata, Antonella ;
Nicolini, Giorgia ;
Vanetti, Eugenio ;
Clivio, Alessandro ;
Winkler, Peter ;
Cozzi, Luca .
PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (09) :2375-2390
[9]   Fast acceleration-encoded magnetic resonance imaging [J].
Forster, J ;
Sieverding, L ;
Breuer, J ;
Lutz, O ;
Schick, F .
MEDICAL PHYSICS, 2001, 28 (01) :28-35
[10]   Intrafraction Variability and Deformation Quantification in the Breast [J].
Glide-Hurst, Carri K. ;
Shah, Mira M. ;
Price, Ryan G. ;
Liu, Chang ;
Kim, Jinkoo ;
Mahan, Meredith ;
Fraser, Correen ;
Chetty, Indrin J. ;
Aref, Ibrahim ;
Movsas, Benjamin ;
Walker, Eleanor M. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2015, 91 (03) :604-611