Comparison of macroscopic resorption time for a self-locking device and suture material in ovarian pedicle ligation in dogs

被引:3
作者
da Mota Costa, Matheus Roberto [1 ]
de Abreu Oliveira, Andre Lacerda [1 ]
de Moura Vidal, Leonardo Waldstein [1 ]
Ramos, Renato Moran [1 ]
Campos, Ingrid de Oliveira [1 ]
Hansson, Kerstin [2 ]
Ley, Charles J. [2 ]
Olsson, Ulf [3 ]
Borg, Niklas Olov [4 ]
Hoglund, Odd Viking [2 ,4 ]
机构
[1] Univ Estadual Norte Fluminense, Dept Anim Clin & Surg, Alberto, Brazil
[2] Swedish Univ Agr Sci, Dept Clin Sci, Uppsala, Sweden
[3] Swedish Univ Agr Sci, Dept Energy & Technol, Appl Stat & Math, Uppsala, Sweden
[4] Resorbable Devices AB, Uppsala, Sweden
关键词
NYLON CABLE BAND; HYDROLYTIC DEGRADATION; IN-VITRO; OVARIOHYSTERECTOMY; COPOLYMER; 1ST;
D O I
10.1136/vr.104732
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
A resorbable self-locking device (LigaTie) was developed to enable safe and easy surgical ligation of blood vessels. The aim of this study was to compare the long-term in vivo resorption of the device to a commercially available suture of equivalent material (Maxon) following ovarian pedicle ligation. After ovariohysterectomy follow-up ultrasound examinations were performed monthly on 21 dogs ligated with the device and 22 dogs ligated with the suture material until no hyperechoic remnants, acoustic shadowing or local tissue reactions were detected. In both groups, the ovarian pedicles gradually decreased in size. Ligation material was considered macroscopically resorbed when ultrasound showed no signs of the device or suture, ovarian pedicle or tissue reaction. Macroscopic resorption had occurred without signs of complications and was complete by four months for sutures and 5.5 months for the device. The results show that resorption time in vivo for the resorbable self-locking device is mildly longer than suture of the same material and that no complications of device resorption were detected, supporting that the resorbable self-locking device is safe for in vivo use.
引用
收藏
页数:6
相关论文
共 40 条
  • [1] Degradation profile and preliminary clinical testing of a resorbable device for ligation of blood vessels
    Aminlashgari, Nina
    Hoglund, Odd V.
    Borg, Niklas
    Hakkarainen, Minna
    [J]. ACTA BIOMATERIALIA, 2013, 9 (06) : 6898 - 6904
  • [2] Foreign body reaction to biomaterials
    Anderson, James M.
    Rodriguez, Analiz
    Chang, David T.
    [J]. SEMINARS IN IMMUNOLOGY, 2008, 20 (02) : 86 - 100
  • [3] [Anonymous], 2004, Applied longitudinal analysis
  • [4] EFFECT OF GAMMA-IRRADIATION AND IRRADIATION TEMPERATURE ON HYDROLYTIC DEGRADATION OF SYNTHETIC ABSORBABLE SUTURES
    CHU, CC
    ZHANG, L
    COYNE, LD
    [J]. JOURNAL OF APPLIED POLYMER SCIENCE, 1995, 56 (10) : 1275 - 1294
  • [5] Ligation of the mesovarium in dogs with a self-locking implant of a resorbable polyglycolic based co-polymer: A study of feasibility and comparison to suture ligation
    Da Mota Costa M.R.
    De Abreu Oliveira A.L.
    Ramos R.M.
    De Moura Vidal L.W.
    Borg N.
    Höglund O.V.
    [J]. BMC Research Notes, 9 (1)
  • [6] Hydrolytic degradation of polyglyconate B: the relationship between degradation time, strength and molecular weight
    Farrar, DF
    Gillson, RK
    [J]. BIOMATERIALS, 2002, 23 (18) : 3905 - 3912
  • [7] Resorbable Self-Locking Implant for Lung Lobectomy Through Video-Assisted Thoracoscopic Surgery: First Live Animal Application
    Guedes, Rogerio Luizari
    Hoglund, Odd Viking
    Brum, Juliana Sperotto
    Borg, Niklas
    Dornbusch, Peterson Triches
    [J]. SURGICAL INNOVATION, 2018, 25 (02) : 158 - 164
  • [8] H?glund, 2017, US patent, Patent No. [9,730,699 B2, 9730699]
  • [9] Dynamic mechanical studies of hydrolytic degradation in isotropic and oriented Maxon B
    Hill, SP
    de Oca, HM
    Klein, PG
    Ward, IM
    Rose, J
    Farrar, D
    [J]. BIOMATERIALS, 2006, 27 (17) : 3168 - 3177
  • [10] Three-year results from a preclinical implantation study of a long-term resorbable surgical mesh with time-dependent mechanical characteristics
    Hjort, H.
    Mathisen, T.
    Alves, A.
    Clermont, G.
    Boutrand, J. P.
    [J]. HERNIA, 2012, 16 (02) : 191 - 197