Impact of varying diastolic pressure fitting technique for the reservoir-wave model on wave intensity analysis

被引:0
|
作者
Pomella, Nicola [1 ,2 ,5 ]
Rietzschel, Ernst R. [3 ]
Segers, Patrick [4 ]
Khir, Ashraf William [1 ]
机构
[1] Brunel Univ London, Biomed Engn Res Grp, Kingston Lane, Uxbridge UB8 3PH, Middx, England
[2] Queen Mary Univ London, Blizard Inst, Ctr Genom & Child Hlth, London, England
[3] Ghent Univ Hosp, Dept Cardiovasc Dis, Ghent, Belgium
[4] Univ Ghent, IBiTechbbioMMeda, Ghent, Belgium
[5] Queen Mary Univ London, Blizard Inst, Ctr Genom & Child Hlth, London, England
关键词
Blood flow measurement; cardiovascular system mechanics; hemodynamics; mathematical modeling [medical; medical signal processing; reservoir pressure; asymptotic pressure; wave intensity analysis; ARTERIAL; SEPARATION; VELOCITY; WINDKESSEL;
D O I
10.1177/0954411920959957
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The reservoir-wave model assumes that the measured arterial pressure is made of two components: reservoir and excess. The effect of the reservoir volume should be excluded to quantify the effects of forward and backward traveling waves on blood pressure. Whilst the validity of the reservoir-wave concept is still debated, there is no consensus on the best fitting method for the calculation of the reservoir pressure waveform. Therefore, the aim of this parametric study is to examine the effects of varying the fitting technique on the calculation of reservoir and excess components of pressure and velocity waveforms. Common carotid pressure and flow velocity were measured using applanation tonometry and doppler ultrasound, respectively, in 1037 healthy humans collected randomly from the Asklepios population, aged 35 to 55 years old. Different fitting techniques to the diastolic decay of the measured arterial pressure were used to determine the asymptotic pressure decay, which in turn was used to determine the reservoir pressure waveform. The corresponding wave speed was determined using the PU-loop method, and wave intensity parameters were calculated and compared. Different fitting methods resulted in significant changes in the shape of the reservoir pressure waveform; however, its peak and time integral remained constant in this study. Although peak and integral of excess pressure, velocity components and wave intensity changed significantly with changing the diastolic decay fitting method, wave speed was not substantially modified. We conclude that wave speed, peak reservoir pressure and its time integral are independent of the diastolic pressure decay fitting techniques examined in this study. Therefore, these parameters are considered more reliable diagnostic indicators than excess pressure and velocity which are more sensitive to fitting techniques.
引用
收藏
页码:1300 / 1311
页数:12
相关论文
共 30 条
  • [1] Implications of Changing the Asymptotic Diastolic Pressure in the Reservoir-wave Model on Wave Intensity Parameters: A Parametric Study
    Pomella, N.
    Rietzschel, E. R.
    Segers, P.
    Khir, Ashraf W.
    ARTERY RESEARCH, 2020, 26 (04) : 228 - 235
  • [2] Wave intensity analysis and the development of the reservoir-wave approach
    Tyberg, John V.
    Davies, Justin E.
    Wang, Zhibin
    Whitelaw, William A.
    Flewitt, Jacqueline A.
    Shrive, Nigel G.
    Francis, Darryl P.
    Hughes, Alun D.
    Parker, Kim H.
    Wang, Jiun-Jr
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2009, 47 (02) : 221 - 232
  • [3] The ebbing tide of the reservoir-wave model
    Mynard, Jonathan P.
    Smolich, Joseph J.
    Avolio, Alberto
    JOURNAL OF HYPERTENSION, 2015, 33 (03) : 461 - 464
  • [4] The reservoir-wave model
    Kim H. Parker
    Artery Research, 2017, 18 : 87 - 101
  • [5] The reservoir-wave model
    Parker, Kim H.
    ARTERY RESEARCH, 2017, 18 : 87 - 101
  • [6] Wave Separation, Wave Intensity, the Reservoir-Wave Concept, and the Instantaneous Wave-Free Ratio Presumptions and Principles
    Westerhof, Nico
    Segers, Patrick
    Westerhof, Berend E.
    HYPERTENSION, 2015, 66 (01) : 93 - 98
  • [7] Assessment of conceptual inconsistencies in the hybrid reservoir-wave model
    Mynard, Jonathan P.
    2013 35TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2013, : 213 - 216
  • [8] Wave reflections in the pulmonary arteries analysed with the reservoir-wave model
    Bouwmeester, J. Christopher
    Belenkie, Israel
    Shrive, Nigel G.
    Tyberg, John V.
    JOURNAL OF PHYSIOLOGY-LONDON, 2014, 592 (14): : 3053 - 3062
  • [9] The reservoir-wave paradigm introduces error into arterial wave analysis: a computer modelling and in-vivo study
    Mynard, Jonathan P.
    Penny, Daniel J.
    Davidson, Malcolm R.
    Smolich, Joseph J.
    JOURNAL OF HYPERTENSION, 2012, 30 (04) : 734 - 743
  • [10] Partitioning pulmonary vascular resistance using the reservoir-wave model
    Bouwmeester, J. Christopher
    Belenkie, Israel
    Shrive, Nigel G.
    Tyberg, John V.
    JOURNAL OF APPLIED PHYSIOLOGY, 2013, 115 (12) : 1838 - 1845