Biexponential R2*relaxometry for estimation of liver iron concentration in children: A better fit for high liver iron states

被引:5
|
作者
Barrera, Christian A. [1 ]
Khrichenko, Dmitry [1 ]
Serai, Suraj D. [1 ]
Hartung, Helge D. [2 ]
Biko, David M. [1 ]
Otero, Hansel J. [1 ]
机构
[1] Childrens Hosp Philadelphia, Dept Radiol, 34th St & Civ Ctr Blvd, Philadelphia, PA 19104 USA
[2] Childrens Hosp Philadelphia, Dept Pediat, Philadelphia, PA 19104 USA
关键词
R2*relaxometry; iron overload; biexponential fitting; liver; children; T-2* relaxation; MAGNETIC-RESONANCE; CHELATING THERAPY; OVERLOAD; QUANTIFICATION; HEMOSIDERIN; FERRITIN; RELAXATION; FAT; VARIABILITY; REGION;
D O I
10.1002/jmri.26735
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background R2* relaxometry's capacity to calculate liver iron concentration (LIC) is limited in patients with severe overload. Hemosiderin increases in these patients, which exhibits a non-monoexponential decay that renders a failed R2* analysis. Purpose/Hypothesis To evaluate a biexponential R2* relaxometry model in children with different ranges of iron overload. Study Type Retrospective. Population In all, 181 children with different conditions associated with iron overload. Field Strength/Sequence 1.5T, T-2*-weighted gradient echo sequence. Assessment Bi- and monoexponential R2* relaxometry were measured in the liver using two regions of interest (ROIs) using a nonproprietary software: one encompassing the whole liver parenchyma (ROI-1) and the other only the periphery (ROI-2). These were drawn by a single trained observer. The residuals for each fitting model were estimated. A ratio between the residuals of the mono- and biexponential models was calculated to identify the best fitting model. Patients with 1) residual ratio >= 1.5 and 2) R2*(fast) >= R2*(slow) were considered as having a predominant biexponential behavior. Statistical Tests Nonparametric tests, Bland-Altman plots, linear correlation, intraclass correlation coefficient. Patients were divided according to their LIC into stable (n = 23), mild (n = 58), moderate (n = 61), and severe (n = 39). Results The biexponential model was more suitable for patients with severe iron overload when compared with the other three LIC categories (P < 0.001) for both ROIs. For ROI-1, 37 subjects met criteria for a predominant biexponential behavior. The slow component (5.7%) had a lower fraction than the fast component (94.2%). For ROI-2, 22 subjects met criteria for a predominant biexponential behavior. The slow component (4.7%) had a lower fraction than the fast component (95.2%). The intraobserver variability between both ROIs was excellent. Data Conclusion The biexponential R2* relaxometry model is more suitable in children with severe iron overload. Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2019;50:1191-1198.
引用
收藏
页码:1191 / 1198
页数:8
相关论文
共 50 条
  • [1] Inter-method reproducibility of biexponential R2 MR relaxometry for estimation of liver iron concentration
    Pirasteh, Ali
    Yuan, Qing
    Hernando, Diego
    Reeder, Scott B.
    Pedrosa, Ivan
    Yokoo, Takeshi
    MAGNETIC RESONANCE IN MEDICINE, 2018, 80 (06) : 2691 - 2701
  • [2] Comparison of R2*and FerriScan liver iron concentration (LIC) quantification in the clinical classification of Iron overload states
    Sussman, Marshall S.
    Kannengiesser, Stephan A. R.
    Prasla, Shopnil
    Ward, Richard
    Jhaveri, Kartik S.
    MAGNETIC RESONANCE IMAGING, 2024, 113
  • [3] R2 relaxometry based MR imaging for estimation of liver iron content: A comparison between two methods
    Calle-Toro, Juan S.
    Barrera, Christian A.
    Khrichenko, Dmitry
    Otero, Hansel J.
    Serai, Suraj D.
    ABDOMINAL RADIOLOGY, 2019, 44 (09) : 3058 - 3068
  • [4] Quantitative Susceptibility Mapping (QSM) Minimizes Interference From Cellular Pathology in R2☆ Estimation of Liver Iron Concentration
    Li, Jianqi
    Lin, Huimin
    Liu, Tian
    Zhang, Zhuwei
    Prince, Martin R.
    Gillen, Kelly
    Yan, Xu
    Song, Qi
    Hua, Ting
    Zhao, Xiance
    Zhang, Miao
    Zhao, Yu
    Li, Gaiying
    Tang, Guangyu
    Yang, Guang
    Brittenham, Gary M.
    Wang, Yi
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2018, 48 (04) : 1069 - 1079
  • [5] Accuracy of MRI R2*Mapping in Diagnosis of Liver Iron Concentration: A Meta-Analysis
    Cao, Sue
    Gao, Xin
    Wang, Hua
    Chen, Yaoping
    Xu, Jianbo
    Zhang, Jie
    Guo, Ruomi
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2025,
  • [6] A Novel Semiautomatic Parenchyma Extraction Method for Improved MRI R2*Relaxometry of Iron Loaded Liver
    Feng, Yanqiu
    Feng, Meiyan
    Gao, Huashuai
    Zhang, Xinyuan
    Xin, Xuegang
    Feng, Qianjin
    Chen, Wufan
    He, Taigang
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2014, 40 (01) : 67 - 78
  • [7] The Effect of Reducing Repetition Time TR on the Measurement of Liver R2 for the Purpose of Measuring Liver Iron Concentration
    Pavitt, Helen L.
    Aydinok, Yesim
    El-Beshlawy, Amal
    Bayraktaroglu, Selen
    Ibrahim, Ahmed S.
    Hamdy, Mona M.
    Pang, Wenjie
    Sharples, Christopher
    St Pierre, Timothy G.
    MAGNETIC RESONANCE IN MEDICINE, 2011, 65 (05) : 1346 - 1351
  • [8] Complex confounder-corrected R2*mapping for liver iron quantification with MRI
    Hernando, Diego
    Cook, Rachel J.
    Qazi, Naila
    Longhurst, Colin A.
    Diamond, Carol A.
    Reeder, Scott B.
    EUROPEAN RADIOLOGY, 2021, 31 (01) : 264 - 275
  • [9] Reproducibility of liver iron concentration measured by R2*method based on 1.5-T MRI: a meta-analysis
    Cao, Sue
    Zhang, Jie
    Dong, Chenyu
    Que, Yutao
    Gao, Xin
    Guo, Ruomi
    EUROPEAN RADIOLOGY, 2025,
  • [10] Improved MRI R2* Relaxometry of Iron-Loaded Liver with Noise Correction
    Feng, Yanqiu
    He, Taigang
    Gatehouse, Peter D.
    Li, Xinzhong
    Harith Alam, Mohammed
    Pennell, Dudley J.
    Chen, Wufan
    Firmin, David N.
    MAGNETIC RESONANCE IN MEDICINE, 2013, 70 (06) : 1765 - 1774