Sit-to-stand test in children with bronchiectasis: Does it measure functional exercise capacity?

被引:6
作者
Zeren, Melih [1 ]
Gurses, Hulya Nilgun [2 ]
Kulli, Hilal Denizoglu [2 ]
Ucgun, Hikmet [2 ]
Cakir, Erkan [3 ]
机构
[1] Izmir Bakircay Univ, Fac Hlth Sci, Div Physiotherapy & Rehabil, Izmir, Turkey
[2] Bezmialem Vakif Univ, Fac Hlth Sci, Div Physiotherapy & Rehabil, Silahtaraga St 189, Istanbul, Turkey
[3] Bezmialem Vakif Univ, Fac Med, Dept Pediat, Div Pediat Chest Dis, Istanbul, Turkey
来源
HEART & LUNG | 2020年 / 49卷 / 06期
关键词
Bronchiectasis; Children; Functional exercise capacity; Physical performance; Sit-to-stand test; Six-minute walk test; Validity; FIELD WALKING TESTS; CYSTIC-FIBROSIS; DETERMINANTS; PERFORMANCE; TOLERANCE; STATEMENT; PEOPLE; COPD;
D O I
10.1016/j.hrtlng.2020.09.017
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Similar to six-minute walk test (6MWT), sit-to-stand test (STST) is a self-paced test which elicits sub-maximal effort; therefore, it is suggested as an alternative measurement for functional exercise capacity in various pulmonary conditions including COPD and cystic fibrosis. We aimed to investigate the association between 30-second STST (30s-STST) and 6MWT in both children with bronchiectasis (BE) and their healthy counterparts, as well as exploring cardiorespiratory burden and discriminative properties of both tests. Methods: Sixty children (6 to 18-year-old) diagnosed with non-cystic fibrosis BE and 20 age-matched healthy controls were included. Both groups performed 30s-STST and 6MWT. Test results, and heart rate, SpO(2) and dyspnea responses to tests were recorded. Results: Univariate analysis revealed that 30s-STST was able to explain 52% of variance in 6MWT (r = 0.718, p<0.001) in BE group, whereas 20% of variance in healthy controls (r = 0.453, p = 0.045). 6MWT elicited higher changes in heart rate and dyspnea level compared to 30s-STST, indicating it was more physically demanding. Both 30s-STST (21.65 +/- 5.28 vs 26.55 +/- 3.56 repetitions) and 6MWT (538 +/- 85 vs 596 +/- 54 m) were significantly lower in BE group compared to healthy controls (p<0.01). Receiver operating characteristic (ROC) curve analysis revealed an area under the ROC curve (UAC) of 0.765 for 30s-STST and 0.693 for 6MWT in identifying the individuals with or without BE (p<0.05). Comparison between AUCs of 30s-STST and 6MWT yielded no significant difference (p = 0.466), indicating both tests had similar discriminative properties. Conclusions: 30s-STST is found to be a valid alternative measurement for functional exercise capacity in chil-dren with BE. (c) 2020 Elsevier Inc. All rights reserved.
引用
收藏
页码:796 / 802
页数:7
相关论文
共 50 条
  • [31] Exercise capacity assessed with the one-minute sit-to-stand test (1-min STST) and echocardiographic findings in patients with heart failure with preserved ejection fraction (HFpEF)
    Kronberger, Christina
    Mousavi, Roya Anahita
    Ozturk, Begum
    Dachs, Theresa-Marie
    Rettl, Rene
    Camuz-Ligios, Luciana
    Litschauer, Brigitte
    Badr-Eslam, Roza
    HEART & LUNG, 2022, 55 : 134 - 139
  • [32] Clinical measurement of sit-to-stand performance in people with balance disorders: Validity of data for the five-times-sit-to-stand test
    Whitney, SL
    Wrisley, DM
    Marchetti, GF
    Gee, MA
    Redfern, MS
    Furman, JM
    PHYSICAL THERAPY, 2005, 85 (10): : 1034 - 1045
  • [33] Estimating balance, cognitive function, and falls risk using wearable sensors and the sit-to-stand test
    Greene, Barry R.
    Doheny, Emer P.
    Mcmanus, Killian
    Caulfield, Brian
    WEARABLE TECHNOLOGIES, 2022, 3
  • [34] Test-Retest Reliability of Functional Electromechanical Dynamometer on Five Sit-to-Stand Measures in Healthy Young Adults
    Jerez-Mayorga, Daniel
    Huerta-Ojeda, Alvaro
    Javier Chirosa-Rios, Luis
    Guede-Rojas, Francisco
    Guzman-Guzman, Iris Paola
    Intelangelo, Leonardo
    Miranda-Fuentes, Claudia
    Delgado-Floody, Pedro
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2021, 18 (13)
  • [35] The Correlation of Sit-to-Stand Tests with COPD Assessment Test and GOLD Staging Classification
    Kakavas, Sotirios
    Papanikolaou, Aggeliki
    Kompogiorgas, Steven
    Stavrinoudakis, Eleftherios
    Karayiannis, Dimitrios
    Balis, Evangelos
    COPD-JOURNAL OF CHRONIC OBSTRUCTIVE PULMONARY DISEASE, 2020, 17 (06) : 655 - 661
  • [36] Reliability and Validity of the Sit-to-Stand as a Muscular Power Measure in Older Adults
    Sherwood, Jennifer J.
    Inouye, Cathy
    Webb, Shannon L.
    Jenny, O.
    JOURNAL OF AGING AND PHYSICAL ACTIVITY, 2020, 28 (03) : 455 - 466
  • [37] Which is the best protocol of the sit-to-stand test in patients with COPD?
    Morita, Andrea A.
    Bisca, Gianna W.
    Paes, Thais
    Furlanetto, Karina
    Sant'Anna, Thais
    Schneider, Lorena
    Donaria, Leila
    Nellessen, Aline
    Travassos, Andreia
    Hernandes, Nidia A.
    Pitta, Fabio
    Probst, Vanessa S.
    EUROPEAN RESPIRATORY JOURNAL, 2015, 46
  • [38] Predictive model for the 1-minute sit-to-stand test in healthy children aged 6 to 12 years
    Reychler, Gregory
    Cabillic, Michel
    Mestre, Natalia Morales
    Poncin, William
    Audag, Nicolas
    Caty, Gilles
    ANNALS OF PHYSICAL AND REHABILITATION MEDICINE, 2021, 64 (02)
  • [39] Sit-to-stand ground reaction force characteristics in blind and sighted female children
    Aylar, Mozhgan Faraji
    Jafarnezhadgero, Amir Ali
    Esker, Fatemeh Salari
    GAIT & POSTURE, 2018, 62 : 34 - 40
  • [40] Test-retest reliability of sensor-based sit-to-stand measures in young and older adults
    Regterschot, G. Ruben H.
    Zhang, Wei
    Baldus, Heribert
    Stevens, Martin
    Zijlstra, Wiebren
    GAIT & POSTURE, 2014, 40 (01) : 220 - 224