Sit-to-stand test in children with bronchiectasis: Does it measure functional exercise capacity?

被引:6
|
作者
Zeren, Melih [1 ]
Gurses, Hulya Nilgun [2 ]
Kulli, Hilal Denizoglu [2 ]
Ucgun, Hikmet [2 ]
Cakir, Erkan [3 ]
机构
[1] Izmir Bakircay Univ, Fac Hlth Sci, Div Physiotherapy & Rehabil, Izmir, Turkey
[2] Bezmialem Vakif Univ, Fac Hlth Sci, Div Physiotherapy & Rehabil, Silahtaraga St 189, Istanbul, Turkey
[3] Bezmialem Vakif Univ, Fac Med, Dept Pediat, Div Pediat Chest Dis, Istanbul, Turkey
来源
HEART & LUNG | 2020年 / 49卷 / 06期
关键词
Bronchiectasis; Children; Functional exercise capacity; Physical performance; Sit-to-stand test; Six-minute walk test; Validity; FIELD WALKING TESTS; CYSTIC-FIBROSIS; DETERMINANTS; PERFORMANCE; TOLERANCE; STATEMENT; PEOPLE; COPD;
D O I
10.1016/j.hrtlng.2020.09.017
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Similar to six-minute walk test (6MWT), sit-to-stand test (STST) is a self-paced test which elicits sub-maximal effort; therefore, it is suggested as an alternative measurement for functional exercise capacity in various pulmonary conditions including COPD and cystic fibrosis. We aimed to investigate the association between 30-second STST (30s-STST) and 6MWT in both children with bronchiectasis (BE) and their healthy counterparts, as well as exploring cardiorespiratory burden and discriminative properties of both tests. Methods: Sixty children (6 to 18-year-old) diagnosed with non-cystic fibrosis BE and 20 age-matched healthy controls were included. Both groups performed 30s-STST and 6MWT. Test results, and heart rate, SpO(2) and dyspnea responses to tests were recorded. Results: Univariate analysis revealed that 30s-STST was able to explain 52% of variance in 6MWT (r = 0.718, p<0.001) in BE group, whereas 20% of variance in healthy controls (r = 0.453, p = 0.045). 6MWT elicited higher changes in heart rate and dyspnea level compared to 30s-STST, indicating it was more physically demanding. Both 30s-STST (21.65 +/- 5.28 vs 26.55 +/- 3.56 repetitions) and 6MWT (538 +/- 85 vs 596 +/- 54 m) were significantly lower in BE group compared to healthy controls (p<0.01). Receiver operating characteristic (ROC) curve analysis revealed an area under the ROC curve (UAC) of 0.765 for 30s-STST and 0.693 for 6MWT in identifying the individuals with or without BE (p<0.05). Comparison between AUCs of 30s-STST and 6MWT yielded no significant difference (p = 0.466), indicating both tests had similar discriminative properties. Conclusions: 30s-STST is found to be a valid alternative measurement for functional exercise capacity in chil-dren with BE. (c) 2020 Elsevier Inc. All rights reserved.
引用
收藏
页码:796 / 802
页数:7
相关论文
共 50 条
  • [1] A comparative study of the five-repetition sit-to-stand test and the 30-second sit-to-stand test to assess exercise tolerance in COPD patients
    Zhang, Qin
    Li, Yan-xia
    Li, Xue-lian
    Yin, Yan
    Li, Rui-lan
    Qiao, Xin
    Li, Wei
    Ma, Hai-feng
    Ma, Wen-hui
    Han, Yu-feng
    Zeng, Guang-qiao
    Wang, Qiu-yue
    Kang, Jian
    Hou, Gang
    INTERNATIONAL JOURNAL OF CHRONIC OBSTRUCTIVE PULMONARY DISEASE, 2018, 13 : 2833 - 2839
  • [2] The 1-min sit-to-stand test A simple functional capacity test in cystic fibrosis?
    Radtke, Thomas
    Puhan, Milo A.
    Hebestreit, Helge
    Kriemler, Susi
    JOURNAL OF CYSTIC FIBROSIS, 2016, 15 (02) : 223 - 226
  • [3] One minute sit-to-stand test is an alternative to 6MWT to measure functional exercise performance in COPD patients
    Reychler, Gregory
    Boucard, Eliott
    Peran, Loic
    Pichon, Romain
    Le Ber-Moy, Catherine
    Ouksel, Hakima
    Liistro, Giuseppe
    Chambellan, Arnaud
    Beaumont, Marc
    CLINICAL RESPIRATORY JOURNAL, 2018, 12 (03) : 1247 - 1256
  • [4] Which Sit-to-Stand Test Best Differentiates Functional Capacity in Older People?
    Cruz-Montecinos, Carlos
    Torres-Castro, Rodrigo
    Otto-Yanez, Matias
    Barros-Poblete, Marisol
    Valencia, Carola
    Campos, Alex
    Jadue, Leticia
    Barros, Marcela
    Solis-Navarro, Lilian
    Resqueti, Vanessa
    AMERICAN JOURNAL OF PHYSICAL MEDICINE & REHABILITATION, 2024, 103 (10) : 925 - 928
  • [5] Assessment of the feasibility of 1-min sit-to-stand test in evaluating functional exercise capacity in interstitial lung disease patients
    Singh, Ravi
    Aggarwal, Deepak
    Dutta, Kashish
    Jaggi, Surabhi
    Sodhi, Mandeep Kaur
    Saini, Varinder
    JOURNAL OF EXERCISE REHABILITATION, 2023, 19 (06) : 363 - 369
  • [6] The one-minute sit-to-stand test: A practical tool for assessing functional exercise capacity in patients with COPD in routine clinical practice
    Mellaerts, Paulien
    Demeyer, Heleen
    Blondeel, Astrid
    Vanhoutte, Tim
    Breuls, Sofie
    Wuyts, Marieke
    Coosemans, Iris
    Claes, Lode
    Vandenbergh, Nele
    Beckers, Kaat
    Bossche, Lucas Vanden
    Stylemans, Dimitri
    Janssens, Wim
    Everaerts, Stephanie
    Troosters, Thierry
    CHRONIC RESPIRATORY DISEASE, 2024, 21
  • [7] The reliability and validity of the 30-seconds sit-to-stand test and its capacity for assessment of the functional status of hemodialysis patients
    Figueiredo, Pedro Henrique Scheidt
    Veloso, Larissa Raphaela de Souza
    Lima, Marcia Maria Oliveira
    Vieira, Carlos Filipe Delmondes
    Alves, Frederico Lopes
    Lacerda, Ana Cristina Rodrigues
    Lima, Vanessa Pereira
    Rodrigues, Vanessa Gomes Brandao
    Maciel, Emilio Henrique Barroso
    Costa, Henrique Silveira
    JOURNAL OF BODYWORK AND MOVEMENT THERAPIES, 2021, 27 : 157 - 164
  • [8] The 5-Repetition Sit-to-Stand Test as an Outcome Measure for Pulmonary Rehabilitation in Subjects With Asthma
    Zampogna, Elisabetta
    Pignatti, Patrizia
    Ambrosino, Nicolino
    Cherubino, Francesca
    Fadda, Anna Maria
    Zappa, Martina
    Spanevello, Antonio
    Visca, Dina
    RESPIRATORY CARE, 2021, 66 (05) : 769 - 776
  • [9] Reliability and validity of the five-repetition sit-to-stand test for children with cerebral palsy
    Wang, Tze-Hsuan
    Liao, Hua-Fang
    Peng, Yi-Chun
    CLINICAL REHABILITATION, 2012, 26 (07) : 664 - 671
  • [10] Modified 30-Second Sit-to-Stand Test: Reliability and Validity in Older Adults Unable to Complete Traditional Sit-to-Stand Testing
    McAllister, Linda S.
    Palombaro, Kerstin M.
    JOURNAL OF GERIATRIC PHYSICAL THERAPY, 2020, 43 (03) : 153 - 158