Tracer kinetic model of regional pulmonary function using positron emission tomography

被引:35
作者
Galletti, GG [1 ]
Venegas, JG [1 ]
机构
[1] Harvard Univ, Sch Med, Massachusetts Gen Hosp, Dept Anesthesia & Crit Care, Boston, MA 02114 USA
关键词
modeling; perfusion; ventilation;
D O I
10.1152/japplphysiol.00910.2001
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
To determine the spatial distributions of pulmonary perfusion, shunt, and ventilation, we developed a compartmental model of regional N-13-labeled molecular nitrogen ((NN)-N-13) kinetics measured from positron emission tomography (PET) images. The model features a compartment for right heart and pulmonary vasculature and two compartments for each region of interest: 1) aerated alveolar units and 2) alveolar units with no gas content (shunting). The model was tested on PET data from normal animals (dogs and sheep) and from animals with experimentally injured lungs simulating acute respiratory distress syndrome. The analysis yielded estimates of regional perfusion, shunt fraction, and specific ventilation with excellent goodness-of-fit to the data (R-2 > 0.99). Model parameters were estimated to within 10% accuracy in the presence of exaggerated levels of experimental noise by using a Monte Carlo sensitivity analysis. Main advantages of the present model are that 1) it separates intraregional blood flow to aerated alveolar units from that shunting across nonaerated units and 2) it accounts and corrects for intraregional tracer removal by shunting blood when estimating ventilation from subsequent washout of tracer. The model was thus found to provide estimates of regional parameters of pulmonary function in sizes of lung regions that could potentially approach the intrinsic resolution for PET images of (NN)-N-13 in lung (similar to7.0 mm for a multiring PET camera).
引用
收藏
页码:1104 / 1114
页数:11
相关论文
共 14 条
[1]  
*CAMBR CONTR, 1994, NONL ID TOOLB US GUI
[2]  
COX PN, 1998, AM J RESP CRIT CARE, V157, pA462
[3]  
EIDELMAN DH, 1990, J APPL PHYSIOL, V69, P147
[4]  
HARRIS RS, IN PRESS AM J RESP C
[5]  
HLASTALA MP, 1998, COMPLEXITY LUNG STRU
[6]   Effects of lung motion and tracer kinetics corrections on PET imaging of pulmonary function [J].
Mijailovich, SM ;
Treppo, S ;
Venegas, JG .
JOURNAL OF APPLIED PHYSIOLOGY, 1997, 82 (04) :1154-1162
[7]   QUANTITATIVE MEASUREMENT OF REGIONAL PULMONARY BLOOD-FLOW WITH POSITRON EMISSION TOMOGRAPHY [J].
MINTUN, MA ;
TERPOGOSSIAN, MM ;
GREEN, MA ;
LICH, LL ;
SCHUSTER, DP .
JOURNAL OF APPLIED PHYSIOLOGY, 1986, 60 (01) :317-326
[8]   QUANTIFICATION OF REGIONAL V/Q RATIOS IN HUMANS BY USE OF PET .1. THEORY [J].
RHODES, CG ;
VALIND, SO ;
BRUDIN, LH ;
WOLLMER, PE ;
JONES, T ;
HUGHES, JMB .
JOURNAL OF APPLIED PHYSIOLOGY, 1989, 66 (04) :1896-1904
[9]   POSITRON EMISSION TOMOGRAPHY - THEORY AND ITS APPLICATION TO THE STUDY OF LUNG-DISEASE [J].
SCHUSTER, DP .
AMERICAN REVIEW OF RESPIRATORY DISEASE, 1989, 139 (03) :818-840
[10]  
SEOW D, 1995, AM J RESP CRIT 2 S4, V151, pA520